Estimating brain and eye lens dose for the cardiologist in interventional cardiology-are the dose levels of concern?

被引:0
|
作者
Hulthen, Markus [1 ]
Tsapaki, Virginia [2 ]
Karambatsakidou, Angeliki [1 ,3 ]
机构
[1] Karolinska Univ Hosp, Dept Med Radiat Phys & Nucl Med, Framstegsgatan 21, S-17176 Stockholm, Sweden
[2] IAEA, Human Hlth Div, Dosimetry & Med Radiat Phys Sect, Vienna, Austria
[3] Karolinska Inst, Dept Oncol Pathol, Anna Stecksens Gata 30, S-17176 Stockholm, Sweden
来源
BRITISH JOURNAL OF RADIOLOGY | 2024年 / 97卷 / 1158期
关键词
conversion coefficients; brain dose; eye lens dose; radiation protection; radiation protection in interventional cardiology; PERCUTANEOUS CORONARY INTERVENTIONS; RADIATION-EXPOSURE; IONIZING-RADIATION; MEDICAL STAFF; RADIOLOGY; RISK; CATARACT; TUMORS; PROTECTION; OPACITIES;
D O I
10.1093/bjr/tqae089
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives To establish conversion coefficients (CCs), between mean absorbed dose to the brain and eye lens of the cardiologist and the air kerma-area product, PKA, for a set of projections in cardiac interventional procedures. Furthermore, by taking clinical data into account, a method to estimate the doses per procedure, or annual dose, is presented.Methods Thermoluminescence dosimeters were used together with anthropomorphic phantoms, simulating a cardiologist performing an interventional cardiac procedure, to estimate the CCs for the brain and eye lens dose for nine standard projections, and change in patient size and x-ray spectrum. Additionally, a single CC has been estimated, accounting for each projections fraction of use in the clinic and associated PKA using clinical data from the dose monitoring system in our hospital.Results The maximum CCs for the eye lens and segment of the brain, is 5.47 mu Gy/Gycm2 (left eye lens) and 1.71 mu Gy/Gycm2 (left brain segment). The corresponding weighted CCs: are 3.39 mu Gy/Gycm2 and 0.89 mu Gy/Gycm2, respectively.Conclusions Conversion coefficients have been established under actual scatter conditions, showing higher doses on the left side of the operator. Using modern interventional x-ray equipment, interventional cardiac procedures will not cause high radiation dose levels to the operator when a ceiling mounted shield is used, otherwise there is a risk that the threshold dose values for cataract will be reached.Advance in knowledge In addition to the CCs for the different projections, methods for deriving a single CC per cardiac interventional procedure and dose per year were introduced.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Assessment of effective dose and dose to the lens of the eye for the interventional cardiologist
    Lie, Oydis Ostbye
    Paulsen, Gudrun Uthaug
    Wohni, Tor
    [J]. RADIATION PROTECTION DOSIMETRY, 2008, 132 (03) : 313 - 318
  • [2] EYE LENS DOSE IN INTERVENTIONAL CARDIOLOGY
    Principi, S.
    Delgado Soler, C.
    Ginjaume, M.
    Beltran Vilagrasa, M.
    Rovira Escutia, J. J.
    Duch, M. A.
    [J]. RADIATION PROTECTION DOSIMETRY, 2015, 165 (1-4) : 289 - 293
  • [3] Eye lens dosimetry in interventional cardiology: results of staff dose measurements and link to patient dose levels
    Antic, V.
    Ciraj-Bjelac, O.
    Rehani, M.
    Aleksandric, S.
    Arandjic, D.
    Ostojic, M.
    [J]. RADIATION PROTECTION DOSIMETRY, 2013, 154 (03) : 276 - 284
  • [4] Staff eye lens dose in interventional radiology and cardiology in Finland
    Pekkarinen, Antti
    Lindholm, Carita
    Kortesniemi, Mika
    Siiskonen, Teemu
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 98 : 1 - 7
  • [5] Occupational radiation dose and protection to the eye lens for interventional cardiology operators
    Lian, Meng-En
    Wu, Guan-Yi
    Chao, Min-Fang
    Wang, Chong-Sheng
    Miao, Hsiao-Chien
    Tsai, Ming-Sung
    Hsieh, Mu-Yang
    Chen, Yeh-Peng
    Chu, Chun-Yuan
    Chang, Szu-Li
    Tsai, Hui-Yu
    [J]. RADIATION MEASUREMENTS, 2022, 154
  • [6] The current status of eye lens dose measurement in interventional cardiology personnel in Thailand
    Krisanachinda A.
    Srimahachota S.
    Matsubara K.
    [J]. Radiological Physics and Technology, 2017, 10 (2) : 142 - 147
  • [7] Influence of dosemeter position for the assessment of eye lens dose during interventional cardiology
    Principi, Sara
    Ginjaume, Merce
    Amor Duch, Maria
    Sanchez, Roberto M.
    Fernandez, Jose M.
    Vano, Eliseo
    [J]. RADIATION PROTECTION DOSIMETRY, 2015, 164 (1-2) : 79 - 83
  • [8] Occupational eye dose in interventional cardiology procedures
    Haga, Yoshihiro
    Chida, Koichi
    Kaga, Yuji
    Sota, Masahiro
    Meguro, Taiichiro
    Zuguchi, Masayuki
    [J]. SCIENTIFIC REPORTS, 2017, 7
  • [9] Occupational eye dose in interventional cardiology procedures
    Yoshihiro Haga
    Koichi Chida
    Yuji Kaga
    Masahiro Sota
    Taiichiro Meguro
    Masayuki Zuguchi
    [J]. Scientific Reports, 7
  • [10] Assessment of the occupational eye lens dose for clinical staff in interventional radiology, cardiology and neuroradiology
    Omar, Artur
    Kadesjo, Nils
    Palmgren, Charlotta
    Marteinsdottir, Maria
    Segerdahl, Tony
    Fransson, Annette
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2017, 37 (01) : 145 - 159