Assessment of effective dose and dose to the lens of the eye for the interventional cardiologist

被引:57
|
作者
Lie, Oydis Ostbye [1 ]
Paulsen, Gudrun Uthaug [1 ]
Wohni, Tor [1 ]
机构
[1] Norwegian Radiat Protect Author, N-1332 Osteras, Norway
关键词
D O I
10.1093/rpd/ncn296
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study investigates the relationship between personal dosemeter (PD) reading, effective dose and dose to the lens of the eye for interventional cardiologists in Norway. Doses were recorded with thermoluminescence dosemeters (TLD-100) for 14 cardiologists, and the effective doses were estimated using the Niklason algorithm. The procedures performed were coronary angiography and percutaneous coronary intervention, and all the hospitals (eight) in Norway, which are performing these procedures, were included in the study. Effective dose per unit dose-area product varied by a factor of 5, and effective dose relative to PD reading varied between 4 and 39%. Eye lens doses ranged from 39 to 138% of the dosemeter reading. On the basis of an estimated annual workload of 900 procedures, the annual effective doses ranged from 1 to 11 mSv. The estimated annual doses to the unprotected eye ranged from 9 to 210 mSv. According to the ICRP dose limits, the results indicate that the eye could be the limiting organ.
引用
收藏
页码:313 / 318
页数:6
相关论文
共 50 条
  • [1] Estimating brain and eye lens dose for the cardiologist in interventional cardiology-are the dose levels of concern?
    Hulthen, Markus
    Tsapaki, Virginia
    Karambatsakidou, Angeliki
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2024, 97 (1158):
  • [2] EYE LENS DOSE IN INTERVENTIONAL CARDIOLOGY
    Principi, S.
    Delgado Soler, C.
    Ginjaume, M.
    Beltran Vilagrasa, M.
    Rovira Escutia, J. J.
    Duch, M. A.
    [J]. RADIATION PROTECTION DOSIMETRY, 2015, 165 (1-4) : 289 - 293
  • [3] Practical guidelines for personal monitoring and estimation of effective dose and dose to the lens of the eye in interventional procedures
    Askounis, Panagiotis
    Gonzalez, Anna Torras
    Ginjaume, Merce
    Carinou, Eleftheria
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2022, 42 (03)
  • [4] Influence of standing positions and beam projections on effective dose and eye lens dose of anaesthetists in interventional procedures
    Kong, Y.
    Struelens, L.
    Vanhavere, F.
    Vargas, C. S.
    Schoonjans, W.
    Zhuo, W. H.
    [J]. RADIATION PROTECTION DOSIMETRY, 2015, 163 (02) : 181 - 187
  • [5] Influence of dosemeter position for the assessment of eye lens dose during interventional cardiology
    Principi, Sara
    Ginjaume, Merce
    Amor Duch, Maria
    Sanchez, Roberto M.
    Fernandez, Jose M.
    Vano, Eliseo
    [J]. RADIATION PROTECTION DOSIMETRY, 2015, 164 (1-2) : 79 - 83
  • [6] Dose estimation of eye lens for interventional procedures in diagnosis
    Liu, Yu-Rong
    Huang, Chia-Yu
    Hsu, Ching-Han
    Hsu, Fang-Yuh
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2017, 140 : 247 - 251
  • [7] A correlation study of eye lens dose and personal dose equivalent for interventional cardiologists
    Farah, J.
    Struelens, L.
    Dabin, J.
    Koukorava, C.
    Donadille, L.
    Jacob, S.
    Schnelzer, M.
    Auvinen, A.
    Vanhavere, F.
    Clairand, I.
    [J]. RADIATION PROTECTION DOSIMETRY, 2013, 157 (04) : 561 - 569
  • [8] Assessment of the occupational eye lens dose for clinical staff in interventional radiology, cardiology and neuroradiology
    Omar, Artur
    Kadesjo, Nils
    Palmgren, Charlotta
    Marteinsdottir, Maria
    Segerdahl, Tony
    Fransson, Annette
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2017, 37 (01) : 145 - 159
  • [9] Eye lens dosimetry for interventional procedures - Relation between the absorbed dose to the lens and dose at measurement positions
    Geber, Therese
    Gunnarsson, Mikael
    Mattsson, Soren
    [J]. RADIATION MEASUREMENTS, 2011, 46 (11) : 1248 - 1251
  • [10] HAND AND EYE LENS DOSES TO CARDIOLOGIST IN INTERVENTIONAL RADIOLOGY
    Repse, Kristina
    Gedvilas, Marius
    [J]. MEDICAL PHYSICS IN THE BALTIC STATES, 2013, : 137 - 139