Assessment of effective dose and dose to the lens of the eye for the interventional cardiologist

被引:57
|
作者
Lie, Oydis Ostbye [1 ]
Paulsen, Gudrun Uthaug [1 ]
Wohni, Tor [1 ]
机构
[1] Norwegian Radiat Protect Author, N-1332 Osteras, Norway
关键词
D O I
10.1093/rpd/ncn296
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study investigates the relationship between personal dosemeter (PD) reading, effective dose and dose to the lens of the eye for interventional cardiologists in Norway. Doses were recorded with thermoluminescence dosemeters (TLD-100) for 14 cardiologists, and the effective doses were estimated using the Niklason algorithm. The procedures performed were coronary angiography and percutaneous coronary intervention, and all the hospitals (eight) in Norway, which are performing these procedures, were included in the study. Effective dose per unit dose-area product varied by a factor of 5, and effective dose relative to PD reading varied between 4 and 39%. Eye lens doses ranged from 39 to 138% of the dosemeter reading. On the basis of an estimated annual workload of 900 procedures, the annual effective doses ranged from 1 to 11 mSv. The estimated annual doses to the unprotected eye ranged from 9 to 210 mSv. According to the ICRP dose limits, the results indicate that the eye could be the limiting organ.
引用
收藏
页码:313 / 318
页数:6
相关论文
共 50 条
  • [41] Occupational eye dose in interventional cardiology procedures
    Haga, Yoshihiro
    Chida, Koichi
    Kaga, Yuji
    Sota, Masahiro
    Meguro, Taiichiro
    Zuguchi, Masayuki
    [J]. SCIENTIFIC REPORTS, 2017, 7
  • [42] Occupational eye dose in interventional cardiology procedures
    Yoshihiro Haga
    Koichi Chida
    Yuji Kaga
    Masahiro Sota
    Taiichiro Meguro
    Masayuki Zuguchi
    [J]. Scientific Reports, 7
  • [43] EYE LENS EXPOSURE TO MEDICAL STAFF PERFORMING ELECTROPHYSIOLOGY PROCEDURES: DOSE ASSESSMENT AND CORRELATION TO PATIENT DOSE
    Ciraj-Bjelac, Olivera
    Antic, Vojislav
    Selakovic, Jovana
    Bozovic, Predrag
    Arandjic, Danijela
    Pavlovic, Sinisa
    [J]. RADIATION PROTECTION DOSIMETRY, 2016, 172 (04) : 475 - 482
  • [44] Evaluation of the dose dependence on the eye lens from the position of the dosimeter for the operators exposed in interventional radiology
    Liverani, A.
    Loffredo, F.
    Fiore, F.
    Correra, M.
    La Verde, G.
    Pugliese, M.
    [J]. NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2018, 41 (06):
  • [45] A method to reduce patient's eye lens dose in neuro-interventional radiology procedures
    Safari, M. J.
    Wong, J. H. D.
    Kadir, K. A. A.
    Sani, F. M.
    Ng, K. H.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2016, 125 : 75 - 81
  • [46] Assessment of the Annual Eye Lens Dose for Cardiologists During Interventional Procedures Using Anthropomorphic Phantoms and mEyeDose_X Tool
    Saeed, Mohammed Khalil
    [J]. CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2020, 21 (04) : 527 - 531
  • [47] Skin dose assessment in interventional radiology
    Greffier, Joel
    Dabli, Djamel
    Frandon, Julien
    Beregi, Jean Paul
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 81 : 170 - 172
  • [48] Effective Dose Assessment for Patients Undergoing Contemporary Fluoroscopically Guided Interventional Procedures
    Li, Xinhua
    Hirsch, Joshua A.
    Rehani, Madan M.
    Yang, Kai
    Liu, Bob
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 214 (01) : 158 - 170
  • [49] The use of effective dose in retrospective dose assessment
    Baverstock, K
    Thorne, MC
    [J]. HEALTH PHYSICS, 2003, 85 (01): : 110 - 111
  • [50] Effective radiation dose and eye lens dose in dental cone beam CT: effect of field of view and angle of rotation
    Pauwels, R.
    Zhang, G.
    Theodorakou, C.
    Walker, A.
    Bosmans, H.
    Jacobs, R.
    Bogaerts, R.
    Horner, K.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2014, 87 (1042):