Dose estimation of eye lens for interventional procedures in diagnosis

被引:3
|
作者
Liu, Yu-Rong [1 ]
Huang, Chia-Yu [3 ]
Hsu, Ching-Han [1 ]
Hsu, Fang-Yuh [1 ,2 ]
机构
[1] Natl Tsing Hua Univ, Dept Biomed Engn & Environm Sci, Hsinchu, Taiwan
[2] Natl Tsing Hua Univ, Nucl Sci & Technol Dev Ctr, Hsinchu, Taiwan
[3] Linkou Chang Gung Mem Hosp, Dept Med Imaging & Intervent, Taoyuan, Taiwan
关键词
Eye-lens dose; Interventional radiology; Occupational exposure; TLD; RADIOLOGY;
D O I
10.1016/j.radphyschem.2017.02.033
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The International Commission on Radiological Protection (ICRP) recommended that the equivalent dose limit for the lens of the eye be decreased from 150 mSv/y (ICRP, 2007) to 20 mSv/y averaged over five years (ICRP, 2011). How to accurately measure the eye-lens dose has, therefore, been an issue of interest recently. Interventional radiologists are at a higher risk of radiation-induced eye injury, such as cataracts, than all other occupational radiation workers. The main objective of this study is to investigate the relationship between the doses to the eye lenses of interventional radiologists measured by different commercial eye-lens dosimeters. This study measured a reference eye-lens dose, which involved placing thermoluminescent dosimeter (TLD) chips at the surface of the eye of the Rando Phantom, and the TLD chips were covered by a 3-mm-thick tissue equivalent bolus. Commercial eye-lens dosimeters, such as a headband dosimeter and standard personnel dose badges, were placed at the positions recommended by the manufacturers. The results show that the personnel dose badge is not an appropriate dosimeter for evaluating eye-lens dose. Dose deviations for different dosimeters are discussed and presented in this study.
引用
收藏
页码:247 / 251
页数:5
相关论文
共 50 条
  • [1] Practical guidelines for personal monitoring and estimation of effective dose and dose to the lens of the eye in interventional procedures
    Askounis, Panagiotis
    Gonzalez, Anna Torras
    Ginjaume, Merce
    Carinou, Eleftheria
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2022, 42 (03)
  • [2] Eye Lens Dose Reduction of Radiologists in Interventional Procedures with Lead Glasses
    Hu, P.
    Zhuo, W.
    Liu, H.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3719 - 3719
  • [3] A Method for Eye Lens Dose Estimation During Fluoroscopically-Guided Neuro-Interventional Procedures
    Xiong, Z.
    Kilian-Meneghin, J.
    Vijayan, S.
    Guo, C.
    Rudin, S.
    Bednarek, D.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 3198 - 3198
  • [4] Eye lens dosimetry for interventional procedures - Relation between the absorbed dose to the lens and dose at measurement positions
    Geber, Therese
    Gunnarsson, Mikael
    Mattsson, Soren
    [J]. RADIATION MEASUREMENTS, 2011, 46 (11) : 1248 - 1251
  • [5] Surgeon eye lens dose monitoring in interventional neuroradiology, cardiovascular and radiology procedures
    Busoni, S.
    Bruzzi, M.
    Giomi, S.
    Poggiali, C.
    Quattrocchi, M.
    Betti, M.
    D'Urso, D.
    Fedeli, L.
    Mazzoni, L. N.
    Paolucci, M.
    Rossi, F.
    Taddeucci, A.
    Bettarini, S.
    Tortoli, P.
    Belli, G.
    Bernardi, L.
    Gasperi, C.
    Campanella, F.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 104 : 123 - 128
  • [6] EYE LENS DOSE IN INTERVENTIONAL CARDIOLOGY
    Principi, S.
    Delgado Soler, C.
    Ginjaume, M.
    Beltran Vilagrasa, M.
    Rovira Escutia, J. J.
    Duch, M. A.
    [J]. RADIATION PROTECTION DOSIMETRY, 2015, 165 (1-4) : 289 - 293
  • [7] Occupational Exposure of the Eye Lens in Interventional Procedures: How to Assess and Manage Radiation Dose
    Ciraj-Bjelac, Olivera
    Carinou, Eleftheria
    Ferrari, Paolo
    Gingaume, Merce
    Merce, Marta Sans
    O'Connor, Una
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2016, 13 (11) : 1347 - 1353
  • [8] Eye lens dose of medical personnel involved in fluoroscopy and interventional procedures at a Malaysian Hospital
    Wong, Jeannie Hsiu Ding
    Anem, Lydia Esther Andrew
    Tan, Suzet
    Tan, Sock Keow
    Ng, Kwan Hoong
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 68 : 47 - 51
  • [9] Lens of the eye dose calculation for neuro-interventional procedures and CBCT scans of the head
    Xiong, Zhenyu
    Vijayan, Sarath
    Rana, Vijay
    Jain, Amit
    Rudin, Stephen
    Bednarek, Daniel R.
    [J]. MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [10] Influence of standing positions and beam projections on effective dose and eye lens dose of anaesthetists in interventional procedures
    Kong, Y.
    Struelens, L.
    Vanhavere, F.
    Vargas, C. S.
    Schoonjans, W.
    Zhuo, W. H.
    [J]. RADIATION PROTECTION DOSIMETRY, 2015, 163 (02) : 181 - 187