Lens of the eye dose calculation for neuro-interventional procedures and CBCT scans of the head

被引:7
|
作者
Xiong, Zhenyu [1 ]
Vijayan, Sarath [1 ]
Rana, Vijay [1 ]
Jain, Amit [1 ]
Rudin, Stephen [1 ]
Bednarek, Daniel R. [1 ]
机构
[1] Univ Buffalo, Toshiba Stroke & Vasc Res Ctr, Buffalo, NY USA
关键词
lens dose; Monte Carlo; EGSnrc; DTS; CBCT; neuro-interventional procedure; RADIATION;
D O I
10.1117/12.2216504
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The aim of this work is to develop a method to calculate lens dose for fluoroscopically-guided neuro-interventional procedures and for CBCT scans of the head. EGSnrc Monte Carlo software is used to determine the dose to the lens of the eye for the projection geometry and exposure parameters used in these procedures. This information is provided by a digital CAN bus on the Toshiba Infinix C-Arm system which is saved in a log file by the real-time skin-dose tracking system (DTS) we previously developed. The x-ray beam spectra on this machine were simulated using BEAMnrc. These spectra were compared to those determined by SpekCalc and validated through measured percent-depth-dose (PDD) curves and half-value-layer (HVL) measurements. We simulated CBCT procedures in DOSXYZnrc for a CTDI head phantom and compared the surface dose distribution with that measured with Gafchromic film, and also for an SK150 head phantom and compared the lens dose with that measured with an ionization chamber. Both methods demonstrated good agreement. Organ dose calculated for a simulated neuro-interventional-procedure using DOSXYZnrc with the Zubal CT voxel phantom agreed within 10% with that calculated by PCXMC code for most organs. To calculate the lens dose in a neuro-interventional procedure, we developed a library of normalized lens dose values for different projection angles and kVp's. The total lens dose is then calculated by summing the values over all beam projections and can be included on the DTS report at the end of the procedure.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Influence of exposure and geometric parameters on absorbed doses associated with common neuro-interventional procedures
    Safari, Mohammad Javad
    Wong, Jeannie Hsiu Ding
    Jong, Wei Loong
    Thorpe, Nathan
    Cutajar, Dean
    Rosenfeld, Anatoly
    Ng, Kwan Hoong
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 35 : 66 - 72
  • [22] EYE LENS DOSE IN INTERVENTIONAL CARDIOLOGY
    Principi, S.
    Delgado Soler, C.
    Ginjaume, M.
    Beltran Vilagrasa, M.
    Rovira Escutia, J. J.
    Duch, M. A.
    RADIATION PROTECTION DOSIMETRY, 2015, 165 (1-4) : 289 - 293
  • [23] Practical guidelines for personal monitoring and estimation of effective dose and dose to the lens of the eye in interventional procedures
    Askounis, Panagiotis
    Gonzalez, Anna Torras
    Ginjaume, Merce
    Carinou, Eleftheria
    JOURNAL OF RADIOLOGICAL PROTECTION, 2022, 42 (03)
  • [24] Evaluation of geometric and exposure parameters used in fluoroscopically-guided neuro-interventional procedures
    Collins, J.
    Troville, J.
    Guo, C.
    Rudin, S.
    Bednarek, D. R.
    MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312
  • [25] Endovascular Thrombectomy for Radial Artery Occlusion in Neuro-Interventional Procedures: A Report of Two Cases
    Atchley, Travis
    Schmalz, Philip
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (01)
  • [26] Occupational Exposure of the Eye Lens in Interventional Procedures: How to Assess and Manage Radiation Dose
    Ciraj-Bjelac, Olivera
    Carinou, Eleftheria
    Ferrari, Paolo
    Gingaume, Merce
    Merce, Marta Sans
    O'Connor, Una
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2016, 13 (11) : 1347 - 1353
  • [27] Eye lens dose of medical personnel involved in fluoroscopy and interventional procedures at a Malaysian Hospital
    Wong, Jeannie Hsiu Ding
    Anem, Lydia Esther Andrew
    Tan, Suzet
    Tan, Sock Keow
    Ng, Kwan Hoong
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 68 : 47 - 51
  • [28] Influence of standing positions and beam projections on effective dose and eye lens dose of anaesthetists in interventional procedures
    Kong, Y.
    Struelens, L.
    Vanhavere, F.
    Vargas, C. S.
    Schoonjans, W.
    Zhuo, W. H.
    RADIATION PROTECTION DOSIMETRY, 2015, 163 (02) : 181 - 187
  • [29] CBCT DOSE CALCULATION ACCURACY IN HEAD AND NECK
    Emmens, D.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S576 - S576
  • [30] Dependence On Calibration Phantom and Field Area of the Conversion Factor Used to Calculate Skin Dose During Neuro-Interventional Fluoroscopic Procedures
    Rana, V. K.
    Vijayan, S.
    Rudin, S. R.
    Bednarek, D. R.
    MEDICAL PHYSICS, 2014, 41 (06) : 134 - 135