Fibrinogen measurement by a novel point-of-care device with whole blood: comparison of values against Clauss method

被引:6
|
作者
Okahara, Shoko [1 ]
Handoh, Tetsuya [2 ]
Wakita, Mitsuru [2 ]
Yamamoto, Takamasa [2 ]
Misawa, Shigeki [2 ]
Miida, Takashi [2 ]
Sumikura, Hiroyuki [1 ]
机构
[1] Juntendo Univ Hosp, Dept Anesthesiol, Bunkyo Ku, 3-1-3 Hongo, Tokyo 1138431, Japan
[2] Juntendo Univ Hosp, Dept Clin Lab, Bunkyo Ku, 3-1-3 Hongo, Tokyo 1138431, Japan
关键词
Clauss method; FibCare; Fibrinogen; Hemorrhage; Point-of-care testing; TRAUMA; PLASMA;
D O I
10.1007/s00540-021-02987-9
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Timely fibrinogen replacement is key to treating critical hemorrhage. Measuring fibrinogen concentration by conventional laboratory tests requires centrifugation of blood samples and is often time-consuming. A point-of-care testing device (A&T, Yokohama, Japan), CG02N, has been available in Japan since 2011 to measure fibrinogen concentration without centrifugation. However, it has not been widely used as it requires dilution of blood samples using manual micropipetting. To further speed up and simplify the fibrinogen measurement, an improved device called FibCare (Atom Medical, Tokyo, Japan) was developed to avoid diluting blood samples. The purpose of this study is to verify the reliability of FibCare against laboratory measurement using the Clauss method. Fibrinogen concentrations with 60 sodium citrated whole blood samples were measured by both FibCare and Clauss methods in the laboratory. Measured values with the Clauss method were distributed in the 88-300 mg/dL range. By comparing these results, a significant positive correlation was observed between the FibCare and Clauss method (Y = 12.402 + 0.982 X; R = 0.891; P < 0.01). The study indicated that FibCare allows accurate measurement of fibrinogen concentration and shows a possibility to contribute to optimal fibrinogen replacement therapy during critical hemorrhage.
引用
收藏
页码:757 / 760
页数:4
相关论文
共 50 条
  • [21] A novel point of care diagnostic device:: Impedimetric detection of a biomarker in whole blood
    McMurray, Amanda A.
    Ali, Zulfiqur
    Kyselovik, Jan
    Mills, Christopher A.
    Renault, Nicole Jaffrezic
    Santha, Hunor
    Strohhoefer, Christof
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 115 - +
  • [22] Comparison of point-of-care device DiaSpect against the HemoCue and laboratory analyser in an ICU population
    Salmond, B.
    Rodseth, R. N.
    Farina, Z.
    von Randen, R. P.
    SOUTHERN AFRICAN JOURNAL OF ANAESTHESIA AND ANALGESIA, 2021, 27 (02) : 99 - 103
  • [23] BLOOD GLUCOSE MEASUREMENT IN PATIENTS WITH SUSPECTED DIABETIC KETOACIDOSIS: A COMPARISON OF ABBOTT MEDISENSE PCX POINT-OF-CARE METER VALUES TO REFERENCE LABORATORY VALUES
    Blank, Fidela S. J.
    Miller, Moses
    Nichols, James
    Smithline, Howard
    Crabb, Gillian
    Pekow, Penelope
    JOURNAL OF EMERGENCY NURSING, 2009, 35 (02) : 93 - 96
  • [24] Assessment of the reliability and validity of a novel point-of-care fibrinogen (F-Point) device against an industry standard at fibrinogen levels &gt;2 g/L in non-haemorrhage scenarios
    Katz, R.
    Efremov, V
    Mooney, C.
    El-Khuffash, A.
    Heaphy, L.
    Cosgrave, D.
    Loughrey, J.
    Thornton, P.
    INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 2020, 43 : 91 - 96
  • [25] Comparison of a novel point-of-care coagulation testing device (Quantra™) with thromboelastography and laboratory testing
    Zghaibe, W.
    Klein, A.
    Besser, M.
    Munting, K.
    Blaudszun, G.
    ANAESTHESIA, 2018, 73 : 16 - 16
  • [26] Evaluation of a whole blood point-of-care coagulation analyzer in dogs
    Conroy, Elizabeth M.
    Lyons, Bridget M.
    Koenig, Amie
    JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2024,
  • [27] Microfluidic device and system for point-of-care blood coagulation measurement based on electrical impedance sensing
    Ramaswamy, Bharath
    Yeh, Yin-Ting Tim
    Zheng, Si-Yang
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 180 : 21 - 27
  • [28] Clinical evaluation of the first medical whole blood, point-of-care testing device for detection of myocardial infarction
    Apple, FS
    Anderson, FP
    Collinson, P
    Jesse, RL
    Kontos, MC
    Levitt, MA
    Miller, EA
    Murakami, MM
    CLINICAL CHEMISTRY, 2000, 46 (10) : 1604 - 1609
  • [29] A Gel-Based Separation-Free Point-of-Care Device for Whole Blood Glucose Detection
    Dai, Jing
    Zhang, Han
    Huang, Can
    Chen, Zheyuan
    Han, Arum
    ANALYTICAL CHEMISTRY, 2020, 92 (24) : 16122 - 16129
  • [30] Innotrac Aio! a point-of-care or a routine analyzer? Analytical performance and plasma/whole blood comparison
    Altinier, Sara
    Zaninotto, Martina
    Mion, Monica Maria
    Plebani, Mario
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2006, 44 (10) : 1278 - 1282