Safety and efficacy of biodegradable polymer-coated thin strut sirolimus-eluting stent vs. durable polymer-coated everolimus-eluting stent in patients with acute myocardial infarction

被引:7
|
作者
Gasior, Pawel [1 ]
Gierlotka, Marek [2 ,3 ]
Szczurek-Katanski, Krzysztof [4 ]
Osuch, Marcin [4 ]
Roleder, Magda [1 ]
Hawranek, Michal [5 ,6 ]
Gasior, Mariusz [5 ,6 ]
Wojakowski, Wojciech [1 ]
Polonski, Lech [5 ,6 ]
机构
[1] Med Univ Silesia, Dept Cardiol & Struct Heart Dis, 45-47 Ziolowa St, PL-40635 Katowice, Poland
[2] Silesian Ctr Heart Dis, Dept Cardiol 3, Zabrze, Poland
[3] Univ Opole, Univ Hosp, Fac Nat Sci & Technol, Dept Cardiol, Opole, Poland
[4] Scanmed, Krakow, Poland
[5] Med Univ Silesia, Sch Med, Dept Cardiol 3, Div Dent Zabrze, Katowice, Poland
[6] Silesian Ctr Heart Dis, Zabrze, Poland
来源
POSTEPY W KARDIOLOGII INTERWENCYJNEJ | 2018年 / 14卷 / 04期
关键词
acute myocardial infarction; bioabsorbable polymer; drug-eluting stents; PERCUTANEOUS CORONARY INTERVENTION; BARE-METAL STENTS; RANDOMIZED CONTROLLED-TRIALS; DUAL ANTIPLATELET THERAPY; NETWORK METAANALYSIS; ARTERY-DISEASE; CLINICAL-OUTCOMES; POOLED ANALYSIS; THROMBOSIS; EVENTS;
D O I
10.5114/aic.2018.79194
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: The biodegradable polymer drug-eluting stents were developed to improve vascular healing. However, further data are needed to confirm the safety and efficacy of these stents in patients with acute myocardial infarction (AMI). Aim: We sought to determine the 1-year clinical follow-up in patients with AMI treated with a thin strut biodegradable polymer-coated sirolimus-eluting stent (BP-SES) versus a durable coating everolimus-eluting stent (DP-EES). Material and methods: We analyzed patients with AMI (STEMI and NSTEMI) treated with either a BP-SES (ALEX, Balton, Poland, n = 886) or DP-EES (XIENCE, Abbott, USA, n = 1054) with available 1-year clinical follow-up using propensity score matching. Outcomes included target vessel revascularization (TVR) as the efficacy outcome and all-cause death, myocardial infarction, and definite/probable stent thrombosis as safety outcomes. Results: After propensity score matching 672 patients treated with BP-SES and 672 patients treated with DP-EES were selected. Procedural and clinical characteristics were similar between the groups. In-hospital mortality was similar in both tested groups. One-year follow-up demonstrated comparable efficacy outcome TVR (BP-SES 7.1% vs. DP-EES 5.2%, p = 0.14), as well as similar safety outcomes of all-cause death, myocardial infarction, and definite/probable stent thrombosis. Conclusions: The thin-strut biodegradable polymer coated sirolimus-eluting stent demonstrated comparable clinical outcomes at 1 year after implantation to the DP-EES. These data support the relative safety and efficacy of BP-SES in AMI patients undergoing percutaneous coronary intervention.
引用
下载
收藏
页码:347 / 355
页数:9
相关论文
共 50 条
  • [21] Long-Term Outcomes of Biodegradable Polymer-Coated Sirolimus-Eluting Stent Implantation for Female Patients
    Han, Yaling
    Qiao, Bing
    Jing, Quanmin
    Wang, Shouli
    Wang, Xiaozeng
    Li, Yi
    CIRCULATION, 2010, 122 (02) : E62 - E63
  • [22] Biolimus-eluting biodegradable polymer-coated stent versus durable polymer-coated sirolimus-eluting stent in unselected patients receiving percutaneous coronary intervention (SORT OUT V): a randomised non-inferiority trial
    Christiansen, Evald Hoj
    Jensen, Lisette Okkels
    Thayssen, Per
    Tilsted, Hans-Henrik
    Krusell, Lars Romer
    Hansen, Knud Norregaard
    Kaltoft, Anne
    Maeng, Michael
    Kristensen, Steen Dalby
    Botker, Hans Erik
    Terkelsen, Christian Juhl
    Villadsen, Anton Boel
    Ravkilde, Jan
    Aaroe, Jens
    Madsen, Morten
    Thuesen, Leif
    Lassen, Jens Flensted
    LANCET, 2013, 381 (9867): : 661 - 669
  • [23] Safety and efficacy of a bioabsorbable polymer-coated, everolimus-eluting coronary stent in patients with diabetes: the EVOLVE II diabetes substudy
    Kereiakes, Dean J.
    Meredith, Ian T.
    Masotti, Monica
    Carrie, Didier
    Moreno, Raul
    Erglis, Andrejs
    Mehta, Shamir R.
    Elhadad, Simon
    Berland, Jacques
    Stein, Bernardo
    Airaksinen, Juhani
    Jobe, R. Lee
    Reitman, Arthur
    Janssens, Luc
    Christen, Thomas
    Dawkins, Keith D.
    Windeeker, Stephan
    EUROINTERVENTION, 2017, 12 (16) : 1987 - 1994
  • [24] Safety and efficacy of Everolimus-Eluting bioabsorbable Polymer-Coated stent in patients with long coronary lesions: The EVOLVE 48 study
    Karmpaliotis, Dimitrios
    Stoler, Robert
    Walsh, Simon
    EI-Jack, Seif
    Potluri, Srinivasa
    Moses, Jeffrey
    Oldroyd, Keith
    Banning, Adrian
    Webster, Mark
    Zaman, Azfar
    Wu, Willis
    Ahmed, Mudassar
    Underwood, Paul
    Allocco, Dominic
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2022, 99 (02) : 373 - 380
  • [25] Efficacy and Safety of a Novel Bioabsorbable Polymer-Coated, Everolimus-Eluting Coronary Stent The EVOLVE II Randomized Trial
    Kereiakes, Dean J.
    Meredith, Ian T.
    Windecker, Stephan
    Jobe, R. Lee
    Mehta, Shamir R.
    Sarembock, Ian J.
    Feldman, Robert L.
    Stein, Bernardo
    Dubois, Christophe
    Grady, Timothy
    Saito, Shigeru
    Kimura, Takeshi
    Christen, Thomas
    Allocco, Dominic J.
    Dawkins, Keith D.
    Circulation-Cardiovascular Interventions, 2015, 8 (04)
  • [26] Comparison of a Novel Biodegradable Polymer Sirolimus-Eluting Stent With a Durable Polymer Everolimus-Eluting Stent: A Systematic Review and Meta-Analysis
    Khalid, Yaser
    Dasu, Neethi
    Dasu, Kirti
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 76 (17) : B115 - B116
  • [27] A novel biodegradable polymer-coated sirolimus-eluting stent: 1-year results of the HELIOS registry
    Zheng Bo
    Liu Yi
    Zhang Ruining
    Yang Wangwei
    Su Fangju
    Wang Rutao
    Chen Dapeng
    Shen Guidong
    Qiu Yumin
    Wang Lianmin
    Chen Chang
    Wu Zhongwei
    Li Fei
    Li Jiayi
    Li Chengxiang
    Gao Chao
    Tao Ling
    for the HELIOS Investigators
    中华医学杂志英文版, 2023, 136 (15)
  • [28] A Promising Approach for Improving the Coating Stability and In Vivo Performance of Biodegradable Polymer-Coated Sirolimus-Eluting Stent
    Bedair, Tarek M.
    Kang, Sung Nam
    Joung, Yoon Ki
    Han, Dong Keun
    JOURNAL OF BIOMEDICAL NANOTECHNOLOGY, 2016, 12 (11) : 2015 - 2028
  • [29] A novel biodegradable polymer-coated sirolimus-eluting stent: 1-year results of the HELIOS registry
    Zheng, Bo
    Liu, Yi
    Zhang, Ruining
    Yang, Wangwei
    Su, Fangju
    Wang, Rutao
    Chen, Dapeng
    Shen, Guidong
    Qiu, Yumin
    Wang, Lianmin
    Chen, Chang
    Wu, Zhongwei
    Li, Fei
    Li, Jiayi
    Li, Chengxiang
    Gao, Chao
    Tao, Ling
    CHINESE MEDICAL JOURNAL, 2023, 136 (15) : 1848 - 1854
  • [30] Sirolimus-eluting, bioerodable polymer-coated constant stent (Cura) in acute ST-elevation myocardial infarction - a safety and feasibility study.
    Lee, CH
    Tan, HC
    Lim, J
    Low, A
    Zhang, XL
    Lim, YT
    AMERICAN JOURNAL OF CARDIOLOGY, 2006, 97 (8B): : 42D - 43D