A Promising Approach for Improving the Coating Stability and In Vivo Performance of Biodegradable Polymer-Coated Sirolimus-Eluting Stent

被引:15
|
作者
Bedair, Tarek M. [1 ,2 ,3 ]
Kang, Sung Nam [1 ,2 ]
Joung, Yoon Ki [1 ,2 ]
Han, Dong Keun [1 ,2 ]
机构
[1] Korea Inst Sci & Technol, Biomed Res Inst, Ctr Biomat, Hwarangno 14 Gil 5, Seoul 02792, South Korea
[2] Korea Univ Sci & Technol, Dept Biomed Engn, 113 Gwahangno, Daejeon 34113, South Korea
[3] Minia Univ, Fac Sci, Dept Chem, El Minia 61519, Egypt
基金
新加坡国家研究基金会;
关键词
Drug-Eluting Stent; Polymer Brush; Drug-In-Polymer Coating; Durability; In-Stent Restenosis; SELF-ASSEMBLED MONOLAYERS; CORONARY STENTS; RELEASE KINETICS; DRUG-RELEASE; SURFACE; PROLIFERATION; DURABILITY; RESTENOSIS; COPOLYMERS; MECHANISM;
D O I
10.1166/jbn.2016.2305
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Several developments are in progress for improving the performance of drug-eluting stents (DESs) including use of biodegradable polymers, polymer-free DES, fully bioabsorbable stents, and so on. The commercially available DESs still suffer from polymer defects that could affect the performance of a DES through a series of adverse events such as coating delamination and/ or peeling-off that lead to non-uniform local drug distribution, restenosis, and thrombosis. The goal of this work was to enhance the stability of drug-in-polymer matrix coating on a stent metal surface through surface modification. The cobalt-chromium (Co-Cr) surface was chemically modified using poly(dopamine) (PDA) nano-coating and poly(L-lactide) (PLLA) nano-brush in order to be applied to a biodegradable polymer-coated DES. The biodegradable polymer loaded with sirolimus was coated using an ultrasonic spray coating instrument. The coating morphology on all samples showed a very smooth and uniform coating. The stability of the coating was evaluated for 2 months under the circulation system in which the drug-in-polymer coating on the PLLA brush-modified stent presented the most stable coating behavior as compared to other samples. The in vitro sirolimus release study from both unmodified and modified stents was studied in phosphate-buffered saline (PBS), and the modified stents showed slower sirolimus release profile as compared to unmodified stents. In vivo study was performed in a porcine coronary artery injury model for 28 days. The percentage of in-stent restenosis area (ISR) for PLLA brush-modified sirolimus-eluting stent (SES) decreased significantly as compared to unmodified SES and bare metal stent (BMS). This study demonstrated that the modification of stent surface using PLLA brushes affects in vitro and in vivo performance effectively to be applied for biodegradable polymercoated DES.
引用
收藏
页码:2015 / 2028
页数:14
相关论文
共 50 条
  • [1] Biodegradable Polymer-Coated Sirolimus-Eluting Stent Implantation in Acute Myocardial Infarction
    Yang Shengli
    Liu Huiliang
    Han Yalin
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (20) : B6 - B7
  • [2] Biodegradable polymer-coated thin strut sirolimus-eluting stent versus durable polymer-coated everolimus-eluting stent in the diabetic population
    Gasior, Pawel
    Gierlotka, Marek
    Szczurek-Katanski, Krzysztof
    Osuch, Marcin
    Roleder, Magda
    Hawranek, Michal
    Wojakowski, Wojciech
    Polonski, Lech
    CARDIOLOGY JOURNAL, 2021, 28 (02) : 235 - 243
  • [3] Angioscopic Findings of Biodegradable Polymer-Coated Biolimus A9-Eluting Stent Implantation: Comparison With Sirolimus-Eluting Stent
    Awata, Masaki
    Uematsu, Masaaki
    Sera, Fusako
    Ishihara, Takayuki
    Watanabe, Tetsuya
    Fujita, Masashi
    Onishi, Toshinari
    Iida, Osamu
    Ishida, Yoshio
    Nanto, Shinsuke
    Nagata, Seiki
    AMERICAN JOURNAL OF CARDIOLOGY, 2011, 107 (8A): : 75A - 75A
  • [4] Angioscopic Comparison of Arterial Repair Between Biodegradable Polymer-Coated Biolimus A9-Eluting Stent and Durable Polymer-Coated Sirolimus-Eluting Stent in Patients
    Awata, Masaki
    Sera, Fusako
    Ishihara, Takayuki
    Watanabe, Tetsuya
    Fujita, Masashi
    Iida, Osamu
    Shin, Okamoto
    Tanaka, Nobuaki
    Dohi, Tomoharu
    Mishima, Tsuyoshi
    Mizugami, Yukika
    Nanto, Kiyonori
    Ishida, Yoshio
    Nanto, Shinsuke
    Uematsu, Masaaki
    Nagata, Seiki
    CIRCULATION, 2010, 122 (21)
  • [5] Angioscopic Assessment of Arterial Repair Following Biodegradable Polymer-Coated Biolimus A9-Eluting Stent Implantation - Comparison With Durable Polymer-Coated Sirolimus-Eluting Stent
    Awata, Masaki
    Uematsu, Masaaki
    Sera, Fusako
    Ishihara, Takayuki
    Watanabe, Tetsuya
    Fujita, Masashi
    Onishi, Toshinari
    Iida, Osamu
    Ishida, Yoshio
    Nanto, Shinsuke
    Nagata, Seiki
    CIRCULATION JOURNAL, 2011, 75 (05) : 1113 - 1119
  • [6] Late restenosis in patients receiving a polymer-coated sirolimus-eluting stent
    Wessely, R
    Kastrati, A
    Schömig, A
    ANNALS OF INTERNAL MEDICINE, 2005, 143 (05) : 392 - 394
  • [7] Preclinical evaluation of the functionality of a polymer-coated sirolimus-eluting stent in pigs
    Perini, Silvio Cesar
    Jesus, Jeanne Louise Fernandes
    Soares, Alessandro Batista
    Ligabue, Rosane Angelica
    Bodanese, Luiz Carlos
    ACTA CIRURGICA BRASILEIRA, 2024, 39
  • [8] A novel biodegradable polymer-coated sirolimus-eluting stent: 1-year results of the HELIOS registry
    Zheng, Bo
    Liu, Yi
    Zhang, Ruining
    Yang, Wangwei
    Su, Fangju
    Wang, Rutao
    Chen, Dapeng
    Shen, Guidong
    Qiu, Yumin
    Wang, Lianmin
    Chen, Chang
    Wu, Zhongwei
    Li, Fei
    Li, Jiayi
    Li, Chengxiang
    Gao, Chao
    Tao, Ling
    CHINESE MEDICAL JOURNAL, 2023, 136 (15) : 1848 - 1854
  • [9] Long-Term Outcomes of Biodegradable Polymer-Coated Sirolimus-Eluting Stent Implantation for Female Patients
    Han, Yaling
    Qiao, Bing
    Jing, Quanmin
    Wang, Shouli
    Wang, Xiaozeng
    Li, Yi
    CIRCULATION, 2010, 122 (02) : E62 - E63
  • [10] A novel biodegradable polymer-coated sirolimus-eluting stent: 1-year results of the HELIOS registry
    Zheng Bo
    Liu Yi
    Zhang Ruining
    Yang Wangwei
    Su Fangju
    Wang Rutao
    Chen Dapeng
    Shen Guidong
    Qiu Yumin
    Wang Lianmin
    Chen Chang
    Wu Zhongwei
    Li Fei
    Li Jiayi
    Li Chengxiang
    Gao Chao
    Tao Ling
    for the HELIOS Investigators
    中华医学杂志英文版, 2023, 136 (15)