A Promising Approach for Improving the Coating Stability and In Vivo Performance of Biodegradable Polymer-Coated Sirolimus-Eluting Stent

被引:15
|
作者
Bedair, Tarek M. [1 ,2 ,3 ]
Kang, Sung Nam [1 ,2 ]
Joung, Yoon Ki [1 ,2 ]
Han, Dong Keun [1 ,2 ]
机构
[1] Korea Inst Sci & Technol, Biomed Res Inst, Ctr Biomat, Hwarangno 14 Gil 5, Seoul 02792, South Korea
[2] Korea Univ Sci & Technol, Dept Biomed Engn, 113 Gwahangno, Daejeon 34113, South Korea
[3] Minia Univ, Fac Sci, Dept Chem, El Minia 61519, Egypt
基金
新加坡国家研究基金会;
关键词
Drug-Eluting Stent; Polymer Brush; Drug-In-Polymer Coating; Durability; In-Stent Restenosis; SELF-ASSEMBLED MONOLAYERS; CORONARY STENTS; RELEASE KINETICS; DRUG-RELEASE; SURFACE; PROLIFERATION; DURABILITY; RESTENOSIS; COPOLYMERS; MECHANISM;
D O I
10.1166/jbn.2016.2305
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Several developments are in progress for improving the performance of drug-eluting stents (DESs) including use of biodegradable polymers, polymer-free DES, fully bioabsorbable stents, and so on. The commercially available DESs still suffer from polymer defects that could affect the performance of a DES through a series of adverse events such as coating delamination and/ or peeling-off that lead to non-uniform local drug distribution, restenosis, and thrombosis. The goal of this work was to enhance the stability of drug-in-polymer matrix coating on a stent metal surface through surface modification. The cobalt-chromium (Co-Cr) surface was chemically modified using poly(dopamine) (PDA) nano-coating and poly(L-lactide) (PLLA) nano-brush in order to be applied to a biodegradable polymer-coated DES. The biodegradable polymer loaded with sirolimus was coated using an ultrasonic spray coating instrument. The coating morphology on all samples showed a very smooth and uniform coating. The stability of the coating was evaluated for 2 months under the circulation system in which the drug-in-polymer coating on the PLLA brush-modified stent presented the most stable coating behavior as compared to other samples. The in vitro sirolimus release study from both unmodified and modified stents was studied in phosphate-buffered saline (PBS), and the modified stents showed slower sirolimus release profile as compared to unmodified stents. In vivo study was performed in a porcine coronary artery injury model for 28 days. The percentage of in-stent restenosis area (ISR) for PLLA brush-modified sirolimus-eluting stent (SES) decreased significantly as compared to unmodified SES and bare metal stent (BMS). This study demonstrated that the modification of stent surface using PLLA brushes affects in vitro and in vivo performance effectively to be applied for biodegradable polymercoated DES.
引用
收藏
页码:2015 / 2028
页数:14
相关论文
共 50 条
  • [31] Biodegradable polymer-coated versus durable polymer-coated sirolimus-eluting stents: the final 5-year outcomes of the I-LOVE-IT 2 trial
    Xu, Kai
    Xu, Bo
    Guan, Changdong
    Jing, Quanmin
    Zheng, Qiangsun
    Li, Xueqi
    Zhao, Xianxian
    Wang, Haichang
    Zhao, Xuezhong
    Li, Yi
    Li, Jing
    Yang, Yuejin
    Han, Yaling
    EUROINTERVENTION, 2021, 16 (18) : E1518 - +
  • [32] Prospective evaluation of an ultrathin strut biodegradable polymer-coated sirolimus-eluting stent: 12 months' results from the S-FLEX UK registry
    Choudhury, Anirban
    Garg, Scot
    Smith, Jamie
    Sharp, Andrew
    de Araujo, Sergio Nabais
    Chauhan, Anoop
    Patel, Nikhil
    Wrigley, Benjamin
    Chattopadhyay, Sudipta
    Zaman, Azfar G.
    BMJ OPEN, 2019, 9 (10):
  • [33] Ultrathin, Biodegradable-Polymer Sirolimus-Eluting Stent vs Thin, Durable-Polymer Everolimus-Eluting Stent
    Nakamura, Masato
    Kadota, Kazushige
    Nakagawa, Yoshihisa
    Tanabe, Kengo
    Ito, Yoshiaki
    Amano, Tetsuya
    Maekawa, Yuichiro
    Takahashi, Akihiko
    Shiode, Nobuo
    Otsuka, Yoritaka
    Kawasaki, Tomohiro
    Hikichi, Yutaka
    Shite, Junya
    Kozuma, Ken
    Iijima, Raisuke
    Murakami, Yoshitaka
    JACC-CARDIOVASCULAR INTERVENTIONS, 2022, 15 (13) : 1324 - 1334
  • [34] Biodegradable polymer coated emodin eluting stent in vitro and in vivo
    Zhao, Yan-Chao
    Gong, Fei-Rong
    Ge, Jun-Bo
    Cheng, Shu-Jun
    Chen, Jian-Ding
    Huadong Ligong Daxue Xuebao /Journal of East China University of Science and Technology, 2008, 34 (02): : 242 - 246
  • [35] ENDOTHELIAL MATURATION AND FUNCTION FOLLOWING IMPLANTATION OF ABLUMINAL COATING BIODEGRADABLE POLYMER BASED SIROLIMUS-ELUTING METALLIC STENT VERSUS CONFORMAL COATING DURABLE POLYMER BASED EVEROLIMUS ELUTING STENT
    Mori, Hiroyoshi
    Cheng, Qi
    Lutter, Christoph
    Acampado, Eduardo
    Guo, Liang
    Kutyna, Matthew
    Torii, Sho
    Harari, Emanuel
    Virmani, Renu
    Finn, Aloke
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (11) : 1066 - 1066
  • [36] Acute Thrombogenicity and Inflammation in Response to a Durable Fluoropolymer Everolimus-Eluting Stent Relative to a Contemporary Sirolimus-Eluting Stent with an Abluminal Biodegradable Polymer Coating
    Torii, Sho
    Cheng, Qi
    Kolodgie, Frank
    Acampado, Eduardo
    Yahagi, Kazuyuki
    Mori, Hiroyoshi
    Romero, Maria
    Perkins, Laura
    Hossainy, Syed
    Pacetti, Stephen
    Finn, Aloke
    Virmani, Renu
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (18) : B188 - B188
  • [37] NOYA I: a prospective randomized trial of noya sirolimus-eluting stent with biodegradable coating compared to FIREBIRD 2 sirolimus-eluting stent with durable coating in patients with coronary artery disease
    Dou, Kefei
    Xu, Bo
    Yang, Yuejin
    Lu, Shuzheng
    Wang, Lefeng
    Wang, Haichang
    Li, Zhanquan
    Wang, Lei
    Zhu, Guoying
    Li, Wei
    Gao, Run-Lin
    CARDIOLOGY, 2011, 120 : 75 - 75
  • [38] NOYA I: A Prospective Randomized Trial or NOYA Sirolimus-Eluting Stent with Biodegradable Coating Compared to FIREBIRD 2 Sirolimus-Eluting Stent with Durable Coating in Patients with Coronary Artery Disease
    Dou, Kefei
    Xu, Bo
    Yang, Yuejin
    Lu, Shuzheng
    Wang, Lefeng
    Wang, Haichang
    Li, Zhanquan
    Wang, Lei
    Zhu, Guoying
    Li, Wei
    Gao, Run-Lin
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (20) : B65 - B65
  • [39] Clinical outcomes for sirolimus-eluting stents and polymer-coated paclitaxel-eluting stents in daily practise
    Saia, Francesco
    Piovaccari, Giancarlo
    Manari, Antonio
    Santarelli, Andrea
    Benassi, Alberto
    Aurier, Enrico
    Sangiorgio, Pietro
    Tarantino, Fabio
    Geraci, Giuseppe
    Vecchi, Giuseppe
    Guastaroba, Paolo
    Grilli, Roberto
    Marzocchi, Antonio
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (07) : 1312 - 1318
  • [40] In-vitro mechanical behavior and in-vivo healing response of a new generation biodegradable polymer-coated thin-strut sirolimus-eluting stents
    Gasior, Pawel
    Pyka, Lukasz
    Hawranek, Michal
    Garbacz, Michal
    Chagnon, Madeline
    Beaudry, Diane
    Fluder, Joanna
    Gasior, Mariusz
    Wojakowski, Wojciech
    Lekston, Andrzej
    KARDIOLOGIA POLSKA, 2022, 80 (01) : 72 - 75