A novel biodegradable polymer-coated sirolimus-eluting stent: 1-year results of the HELIOS registry

被引:0
|
作者
Zheng, Bo [1 ]
Liu, Yi [1 ]
Zhang, Ruining [1 ]
Yang, Wangwei [1 ]
Su, Fangju [1 ]
Wang, Rutao [1 ,2 ,3 ]
Chen, Dapeng [4 ]
Shen, Guidong [5 ]
Qiu, Yumin [6 ]
Wang, Lianmin [7 ]
Chen, Chang [8 ]
Wu, Zhongwei [9 ]
Li, Fei [1 ]
Li, Jiayi [1 ]
Li, Chengxiang [1 ]
Gao, Chao [1 ,2 ,3 ]
Tao, Ling [1 ,10 ]
机构
[1] Air Force Med Univ, Xijing Hosp, Dept Cardiol, Xian 710032, Shaanxi, Peoples R China
[2] Radboud Univ Nijmegen, Dept Cardiol, Nijmegen, Netherlands
[3] Natl Univ Ireland, Dept Cardiol, Galway, Ireland
[4] Ningxia Med Univ, Gen Hosp, Internal Med Heart Ctr, Yinchuan 750003, Ningxia, Peoples R China
[5] Ankang City Cent Hosp, Dept Cardiol, Ankang 725099, Shaanxi, Peoples R China
[6] Ningxia Med Univ, Cardiocerebrovasc Hosp, Dept Cardiovasc, Yinchuan 750002, Ningxia, Peoples R China
[7] Mudanjiang Cardiovasc Hosp, Dept Cardiol, Harbin 157011, Peoples R China
[8] Shantou Univ, Affiliated Hosp 1, Dept Cardiol, Med Coll, Shantou 515041, Guangdong, Peoples R China
[9] Western Cent Hosp Hainan Prov, Dept Cardiol, Danzhou 571700, Hainan, Peoples R China
[10] Air Force Med Univ, Xijing Hosp, Xian 710032, Shaanxi, Peoples R China
关键词
Percutaneous coronary interventions; Titanium oxide film; Sirolimus-eluting stent; Target lesion failure; HELIOS; PERCUTANEOUS CORONARY INTERVENTION; DURABLE POLYMER; CLINICAL-OUTCOMES; ARTERY-DISEASE; UNSELECTED PATIENTS; SAFETY; MULTICENTER; LEADERS; THROMBOSIS; EFFICACY;
D O I
10.1097/CM9.0000000000002324
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background:The HELIOS stent is a sirolimus-eluting stent with a biodegradable polymer and titanium oxide film as the tie-layer. The study aimed to evaluate the safety and efficacy of HELIOS stent in a real-world setting.Methods:The HELIOS registry is a prospective, multicenter, cohort study conducted at 38 centers across China between November 2018 and December 2019. A total of 3060 consecutive patients were enrolled after application of minimal inclusion and exclusion criteria. The primary endpoint was target lesion failure (TLF), defined as a composite of cardiac death, non-fatal target vessel myocardial infarction (MI), and clinically indicated target lesion revascularization (TLR) at 1-year follow-up. Kaplan-Meier methods were used to estimate the cumulative incidence of clinical events and construct survival curves.Results:A total of 2998 (98.0%) patients completed the 1-year follow-up. The 1-year incidence of TLF was 3.10% (94/2998, 95% closed interval: 2.54-3.78%). The rates of cardiac death, non-fatal target vessel MI and clinically indicated TLR were 2.33% (70/2998), 0.20% (6/2998), and 0.70% (21/2998), respectively. The rate of stent thrombosis was 0.33% (10/2998). Age & GE;60 years, diabetes mellitus, family history of coronary artery disease, acute myocardial infarction at admission, and device success were independent predictors of TLF at 1 year.Conclusion:The 1-year incidence rates of TLF and stent thrombosis were 3.10% and 0.33%, respectively, in patients treated with HELIOS stents. Our results provide clinical evidence for interventional cardiologists and policymakers to evaluate HELIOS stent.
引用
收藏
页码:1848 / 1854
页数:7
相关论文
共 50 条
  • [1] A novel biodegradable polymer-coated sirolimus-eluting stent: 1-year results of the HELIOS registry
    Zheng Bo
    Liu Yi
    Zhang Ruining
    Yang Wangwei
    Su Fangju
    Wang Rutao
    Chen Dapeng
    Shen Guidong
    Qiu Yumin
    Wang Lianmin
    Chen Chang
    Wu Zhongwei
    Li Fei
    Li Jiayi
    Li Chengxiang
    Gao Chao
    Tao Ling
    for the HELIOS Investigators
    中华医学杂志英文版, 2023, 136 (15)
  • [2] Biodegradable Polymer-Coated Sirolimus-Eluting Stent Implantation in Acute Myocardial Infarction
    Yang Shengli
    Liu Huiliang
    Han Yalin
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (20) : B6 - B7
  • [3] Biodegradable polymer-coated thin strut sirolimus-eluting stent versus durable polymer-coated everolimus-eluting stent in the diabetic population
    Gasior, Pawel
    Gierlotka, Marek
    Szczurek-Katanski, Krzysztof
    Osuch, Marcin
    Roleder, Magda
    Hawranek, Michal
    Wojakowski, Wojciech
    Polonski, Lech
    CARDIOLOGY JOURNAL, 2021, 28 (02) : 235 - 243
  • [4] Evaluation of prolonged safety and efficacy of biodegradable polymer coated sirolimus-eluting coronary stent system: 1-year outcomes of the INDOLIMUS Registry
    Rajasekhar, Durgaprasad
    Vanajakshamma, Velam
    Vidyasagar, Akula
    Ranganayakulu, Kummaraganti Paramatma
    Babu, Mannuva Boochi
    Sivasankara, Chakali
    Kothari, Shivani
    Thakkar, Ashok
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2015, 5 (04) : 249 - 253
  • [5] Angioscopic Findings of Biodegradable Polymer-Coated Biolimus A9-Eluting Stent Implantation: Comparison With Sirolimus-Eluting Stent
    Awata, Masaki
    Uematsu, Masaaki
    Sera, Fusako
    Ishihara, Takayuki
    Watanabe, Tetsuya
    Fujita, Masashi
    Onishi, Toshinari
    Iida, Osamu
    Ishida, Yoshio
    Nanto, Shinsuke
    Nagata, Seiki
    AMERICAN JOURNAL OF CARDIOLOGY, 2011, 107 (8A): : 75A - 75A
  • [6] Angioscopic Comparison of Arterial Repair Between Biodegradable Polymer-Coated Biolimus A9-Eluting Stent and Durable Polymer-Coated Sirolimus-Eluting Stent in Patients
    Awata, Masaki
    Sera, Fusako
    Ishihara, Takayuki
    Watanabe, Tetsuya
    Fujita, Masashi
    Iida, Osamu
    Shin, Okamoto
    Tanaka, Nobuaki
    Dohi, Tomoharu
    Mishima, Tsuyoshi
    Mizugami, Yukika
    Nanto, Kiyonori
    Ishida, Yoshio
    Nanto, Shinsuke
    Uematsu, Masaaki
    Nagata, Seiki
    CIRCULATION, 2010, 122 (21)
  • [7] Evaluation of Ultrathin Strut Biodegradable Polymer-Coated Sirolimus-Eluting Stents in an All-Comers Patient Population: 1-Year Results of the S-FLEX Slovakia Registry
    Hudec, Martin
    Kupec, Andrej
    Gazdic, Pavol
    ANATOLIAN JOURNAL OF CARDIOLOGY, 2024, 28 (03): : 142 - 149
  • [8] Angioscopic Assessment of Arterial Repair Following Biodegradable Polymer-Coated Biolimus A9-Eluting Stent Implantation - Comparison With Durable Polymer-Coated Sirolimus-Eluting Stent
    Awata, Masaki
    Uematsu, Masaaki
    Sera, Fusako
    Ishihara, Takayuki
    Watanabe, Tetsuya
    Fujita, Masashi
    Onishi, Toshinari
    Iida, Osamu
    Ishida, Yoshio
    Nanto, Shinsuke
    Nagata, Seiki
    CIRCULATION JOURNAL, 2011, 75 (05) : 1113 - 1119
  • [9] Late restenosis in patients receiving a polymer-coated sirolimus-eluting stent
    Wessely, R
    Kastrati, A
    Schömig, A
    ANNALS OF INTERNAL MEDICINE, 2005, 143 (05) : 392 - 394
  • [10] Preclinical evaluation of the functionality of a polymer-coated sirolimus-eluting stent in pigs
    Perini, Silvio Cesar
    Jesus, Jeanne Louise Fernandes
    Soares, Alessandro Batista
    Ligabue, Rosane Angelica
    Bodanese, Luiz Carlos
    ACTA CIRURGICA BRASILEIRA, 2024, 39