Safety and efficacy of biodegradable polymer-coated thin strut sirolimus-eluting stent vs. durable polymer-coated everolimus-eluting stent in patients with acute myocardial infarction

被引:7
|
作者
Gasior, Pawel [1 ]
Gierlotka, Marek [2 ,3 ]
Szczurek-Katanski, Krzysztof [4 ]
Osuch, Marcin [4 ]
Roleder, Magda [1 ]
Hawranek, Michal [5 ,6 ]
Gasior, Mariusz [5 ,6 ]
Wojakowski, Wojciech [1 ]
Polonski, Lech [5 ,6 ]
机构
[1] Med Univ Silesia, Dept Cardiol & Struct Heart Dis, 45-47 Ziolowa St, PL-40635 Katowice, Poland
[2] Silesian Ctr Heart Dis, Dept Cardiol 3, Zabrze, Poland
[3] Univ Opole, Univ Hosp, Fac Nat Sci & Technol, Dept Cardiol, Opole, Poland
[4] Scanmed, Krakow, Poland
[5] Med Univ Silesia, Sch Med, Dept Cardiol 3, Div Dent Zabrze, Katowice, Poland
[6] Silesian Ctr Heart Dis, Zabrze, Poland
来源
POSTEPY W KARDIOLOGII INTERWENCYJNEJ | 2018年 / 14卷 / 04期
关键词
acute myocardial infarction; bioabsorbable polymer; drug-eluting stents; PERCUTANEOUS CORONARY INTERVENTION; BARE-METAL STENTS; RANDOMIZED CONTROLLED-TRIALS; DUAL ANTIPLATELET THERAPY; NETWORK METAANALYSIS; ARTERY-DISEASE; CLINICAL-OUTCOMES; POOLED ANALYSIS; THROMBOSIS; EVENTS;
D O I
10.5114/aic.2018.79194
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: The biodegradable polymer drug-eluting stents were developed to improve vascular healing. However, further data are needed to confirm the safety and efficacy of these stents in patients with acute myocardial infarction (AMI). Aim: We sought to determine the 1-year clinical follow-up in patients with AMI treated with a thin strut biodegradable polymer-coated sirolimus-eluting stent (BP-SES) versus a durable coating everolimus-eluting stent (DP-EES). Material and methods: We analyzed patients with AMI (STEMI and NSTEMI) treated with either a BP-SES (ALEX, Balton, Poland, n = 886) or DP-EES (XIENCE, Abbott, USA, n = 1054) with available 1-year clinical follow-up using propensity score matching. Outcomes included target vessel revascularization (TVR) as the efficacy outcome and all-cause death, myocardial infarction, and definite/probable stent thrombosis as safety outcomes. Results: After propensity score matching 672 patients treated with BP-SES and 672 patients treated with DP-EES were selected. Procedural and clinical characteristics were similar between the groups. In-hospital mortality was similar in both tested groups. One-year follow-up demonstrated comparable efficacy outcome TVR (BP-SES 7.1% vs. DP-EES 5.2%, p = 0.14), as well as similar safety outcomes of all-cause death, myocardial infarction, and definite/probable stent thrombosis. Conclusions: The thin-strut biodegradable polymer coated sirolimus-eluting stent demonstrated comparable clinical outcomes at 1 year after implantation to the DP-EES. These data support the relative safety and efficacy of BP-SES in AMI patients undergoing percutaneous coronary intervention.
引用
下载
收藏
页码:347 / 355
页数:9
相关论文
共 50 条
  • [31] Twelve-month comparative analysis of clinical outcomes using biodegradable polymer-coated everolimus-eluting stents versus durable polymer-coated everolimus-eluting stents in all-comer patients
    Abhyankar, Atul
    Sandhu, Manjinder Singh
    Polavarapu, Raghava Sarma
    INDIAN HEART JOURNAL, 2019, 71 (02) : 149 - 154
  • [32] HEALTH ECONOMIC EVALUATION OF AN ULTRATHIN, BIORESORBABLE POLYMER SIROLIMUS-ELUTING CORONARY STENT COMPARED TO A THIN, DURABLE POLYMER EVEROLIMUS-ELUTING STENT
    Mattke, S.
    Hanson, M.
    Dallmann, A.
    Bentele, M.
    VALUE IN HEALTH, 2018, 21 : S245 - S245
  • [33] Comparison of a Novel Biodegradable Polymer Sirolimus-Eluting Stent With a Durable Polymer Everolimus-Eluting Stent Results of the Randomized BIOFLOW-II Trial
    Windecker, Stephan
    Haude, Michael
    Neumann, Franz-Josef
    Stangl, Karl
    Witzenbichler, Bernhard
    Slagboom, Ton
    Sabate, Manel
    Goicolea, Javier
    Barragan, Paul
    Cook, Stephane
    Piot, Christophe
    Richardt, Gert
    Merkely, Bela
    Schneider, Henrik
    Bilger, Johannes
    Erne, Paul
    Waksman, Ron
    Zaugg, Serge
    Jueni, Peter
    Lefevre, Thierry
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (02)
  • [34] Healing and early stent coverage after ultrathin strut biodegradable polymer-coated sirolimus-eluting stent implantation: SiBi optical coherence tomography study
    Abhyankar, Atul
    Abizaid, Alexandre
    Chamie, Daniel
    Patel, Gaurang
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2021, 98 (07) : 1335 - 1342
  • [35] Acute Thrombogenicity and Inflammation in Response to a Durable Fluoropolymer Everolimus-Eluting Stent Relative to a Contemporary Sirolimus-Eluting Stent with an Abluminal Biodegradable Polymer Coating
    Torii, Sho
    Cheng, Qi
    Kolodgie, Frank
    Acampado, Eduardo
    Yahagi, Kazuyuki
    Mori, Hiroyoshi
    Romero, Maria
    Perkins, Laura
    Hossainy, Syed
    Pacetti, Stephen
    Finn, Aloke
    Virmani, Renu
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (18) : B188 - B188
  • [36] Final five-year outcomes after implantation of biodegradable polymer-coated biolimus-eluting stents versus durable polymer-coated sirolimus-eluting stents
    Jakobsen, Lars
    Christiansen, Evald H.
    Maeng, Michael
    Hansen, Knud N.
    Kristensen, Steen D.
    Botker, Hans E.
    Terkelsen, Christian J.
    Jensen, Svend E.
    Raungaard, Bent
    Madsen, Morten
    Lassen, Jens F.
    Jensen, Lisette O.
    EUROINTERVENTION, 2017, 13 (11) : 1337 - 1345
  • [37] Comparison of Sirolimus-eluting, Everolimus-eluting, Biodegradable Polymer stent, and Endothelial Progenitor Cell Capture stent in Patients with ST-elevation Myocardial Infarction
    Park, Hyun Woo
    Park, Heesoon
    Kang, Se Hun
    Cheon, Sang Soo
    Kim, Min Su
    Bae, Byeong Joo
    Roh, Jae Hyung
    Chang, Mineok
    Yoon, Sung-Han
    Ahn, Jung-Min
    Lee, Jong-Young
    Kang, Soo-Jin
    Park, Duk-Woo
    Lee, Seung-Whan
    Kim, Young-Hak
    Lee, Cheol Whan
    Park, Seong-Wook
    Park, Seung-Jung
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (11) : B11 - B12
  • [38] Sirolimus-eluting, bioabsorbable polymer-coated constant stent (CuraTM) in acute ST-elevation myocardial infarction -: a clinical and angiographic study
    Lee, Chi-Hang
    Lim, Jimmy
    Low, Adrian
    Zhang, Xiao-Ling
    Kyaing, Than-Than
    Chan, Mark Y.
    Wong, Hwee-Bee
    Lim, Yean-Teng
    Tan, Huay-Cheem
    AMERICAN JOURNAL OF CARDIOLOGY, 2006, 98 (8A): : 17M - 17M
  • [39] Sirolimus-eluting stent vs. everolimus-eluting stent to percutaneous coronary intervention in dialysis patients
    Ishii, H.
    Kumada, Y.
    Toriyama, T.
    Aoyama, T.
    Takahashi, H.
    Yoshikawa, D.
    Amano, T.
    Tanaka, M.
    Kamoi, D.
    Murohara, T.
    EUROPEAN HEART JOURNAL, 2011, 32 : 1040 - 1040
  • [40] Sirolimus-Eluting Stent vs. Everolimus-Eluting Stent for Coronary Intervention in Patients on Chronic Hemodialysis
    Sakakibara, Takashi
    Ishii, Hideki
    Toriyama, Takanobu
    Aoyama, Toru
    Takahashi, Hiroshi
    Kamoi, Daisuke
    Kawamura, Yoshihiro
    Kawashima, Kazuhiro
    Yoneda, Kohei
    Amano, Tetsuya
    Tanaka, Miho
    Yoshikawa, Daiji
    Hayashi, Mutsuharu
    Matsubara, Tatsuaki
    Murohara, Toyoaki
    CIRCULATION JOURNAL, 2012, 76 (02) : 351 - 355