Safety and efficacy of biodegradable polymer-coated thin strut sirolimus-eluting stent vs. durable polymer-coated everolimus-eluting stent in patients with acute myocardial infarction

被引:7
|
作者
Gasior, Pawel [1 ]
Gierlotka, Marek [2 ,3 ]
Szczurek-Katanski, Krzysztof [4 ]
Osuch, Marcin [4 ]
Roleder, Magda [1 ]
Hawranek, Michal [5 ,6 ]
Gasior, Mariusz [5 ,6 ]
Wojakowski, Wojciech [1 ]
Polonski, Lech [5 ,6 ]
机构
[1] Med Univ Silesia, Dept Cardiol & Struct Heart Dis, 45-47 Ziolowa St, PL-40635 Katowice, Poland
[2] Silesian Ctr Heart Dis, Dept Cardiol 3, Zabrze, Poland
[3] Univ Opole, Univ Hosp, Fac Nat Sci & Technol, Dept Cardiol, Opole, Poland
[4] Scanmed, Krakow, Poland
[5] Med Univ Silesia, Sch Med, Dept Cardiol 3, Div Dent Zabrze, Katowice, Poland
[6] Silesian Ctr Heart Dis, Zabrze, Poland
来源
POSTEPY W KARDIOLOGII INTERWENCYJNEJ | 2018年 / 14卷 / 04期
关键词
acute myocardial infarction; bioabsorbable polymer; drug-eluting stents; PERCUTANEOUS CORONARY INTERVENTION; BARE-METAL STENTS; RANDOMIZED CONTROLLED-TRIALS; DUAL ANTIPLATELET THERAPY; NETWORK METAANALYSIS; ARTERY-DISEASE; CLINICAL-OUTCOMES; POOLED ANALYSIS; THROMBOSIS; EVENTS;
D O I
10.5114/aic.2018.79194
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: The biodegradable polymer drug-eluting stents were developed to improve vascular healing. However, further data are needed to confirm the safety and efficacy of these stents in patients with acute myocardial infarction (AMI). Aim: We sought to determine the 1-year clinical follow-up in patients with AMI treated with a thin strut biodegradable polymer-coated sirolimus-eluting stent (BP-SES) versus a durable coating everolimus-eluting stent (DP-EES). Material and methods: We analyzed patients with AMI (STEMI and NSTEMI) treated with either a BP-SES (ALEX, Balton, Poland, n = 886) or DP-EES (XIENCE, Abbott, USA, n = 1054) with available 1-year clinical follow-up using propensity score matching. Outcomes included target vessel revascularization (TVR) as the efficacy outcome and all-cause death, myocardial infarction, and definite/probable stent thrombosis as safety outcomes. Results: After propensity score matching 672 patients treated with BP-SES and 672 patients treated with DP-EES were selected. Procedural and clinical characteristics were similar between the groups. In-hospital mortality was similar in both tested groups. One-year follow-up demonstrated comparable efficacy outcome TVR (BP-SES 7.1% vs. DP-EES 5.2%, p = 0.14), as well as similar safety outcomes of all-cause death, myocardial infarction, and definite/probable stent thrombosis. Conclusions: The thin-strut biodegradable polymer coated sirolimus-eluting stent demonstrated comparable clinical outcomes at 1 year after implantation to the DP-EES. These data support the relative safety and efficacy of BP-SES in AMI patients undergoing percutaneous coronary intervention.
引用
下载
收藏
页码:347 / 355
页数:9
相关论文
共 50 条
  • [41] Individual Patient Data Analysis of the BIOFLOW Study Program Comparing Safety and Efficacy of a Bioresorbable Polymer Sirolimus-Eluting Stent to a Durable Polymer Everolimus-Eluting Stent
    Richardt, Gert
    Lefevre, Thierry
    Saito, Shigeru
    Kandzari, David
    Koolen, J. J.
    Toelg, Ralph
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 74 (13) : B275 - B275
  • [42] Thin, Very Thin, or Ultrathin Strut Biodegradable or Durable Polymer-Coated Drug-Eluting Stents
    Buiten, Rosaly A.
    Ploumen, Eline H.
    Zocca, Paolo
    Doggen, Carine J. M.
    Danse, Peter W.
    Schotborgh, Carl E.
    Scholte, Martijn
    van Houwelingen, K. Gert
    Stoel, Martin G.
    Hartmann, Marc
    Gin, R. Melvyn Tjon Joe
    Somi, Samer
    Linssen, Gerard C. M.
    Kok, Marlies M.
    von Birgelen, Clemens
    JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (17) : 1650 - 1660
  • [43] Clinical outcomes of complex lesions treated with an abluminal groove-filled biodegradable polymer sirolimus-eluting stent and durable polymer everolimus-eluting stent
    Saito, Yuichi
    Baumbach, Andreas
    Wijns, William
    Xu, Bo
    Kelbaek, Henning
    Zheng, Ming
    Morel, Marie-angele
    Anderson, Richard
    Schaechinger, Volker
    Lansky, Alexandra
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2020, 96 (05) : 1023 - 1028
  • [44] Randomised study of a bioabsorbable polymer-coated sirolimus-eluting stent: results of the DESSOLVE II trial
    Wijns, William
    Vrolix, Mathias
    Verheye, Stefan
    Schoors, Danny
    Slagboom, Ton
    Gosselink, Marcel
    Benit, Edouard
    Donohoe, Dennis
    Knape, Charlene
    Attizzani, Guilherme F.
    Lansky, Alexandra J.
    Ormiston, John
    EUROINTERVENTION, 2015, 10 (12) : 1383 - 1390
  • [45] Comparison of neointimal coverage between ultrathin biodegradable polymer-coated sirolimus-eluting stents and durable polymer-coated everolimus-eluting stents: 6 months optical coherence tomography follow-up from the TAXCO study
    Abhyankar, Atul
    Abizaid, Alexandre
    Chamie, Daniel
    Rathod, Mihir
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2021, 97 (03) : 423 - 430
  • [46] Long-Term Safety and Efficacy of a Biodegradable Polymer-Coated Sirolimus-Eluting Stent: 30-Month Clinical Outcome of the CREATE Registry
    Han, Yaling
    Jing, Quanming
    Li, Yi
    Yan, Gaoliang
    Wang, Shouli
    Ma, Yingyan
    Luan, Bo
    Wang, Geng
    CIRCULATION, 2010, 122 (02) : E53 - E53
  • [47] Outcomes of a novel abluminal bioabsorbable versus durable polymer-coated everolimus-eluting stent in complex patients and coronary artery disease
    Pllaha, E.
    Mennuni, M.
    Stefanini, G.
    Pagnotta, P.
    Araco, M.
    Reimers, B.
    Sardella, G.
    Presbitero, P.
    EUROPEAN HEART JOURNAL, 2016, 37 : 808 - 808
  • [48] Ultrathin Strut Biodegradable Polymer Sirolimus-Eluting Stent Versus Durable-Polymer Everolimus-Eluting Stent for Percutaneous Coronary Revascularization: 2-Year Results of the BIOSCIENCE Trial
    Zbinden, Rainer
    Piccolo, Raffaele
    Heg, Dik
    Roffi, Marco
    Kurz, David J.
    Muller, Olivier
    Vuilliomenet, Andre
    Cook, Stephane
    Weilenmann, Daniel
    Kaiser, Christoph
    Jamshidi, Peiman
    Franzone, Anna
    Eberli, Franz
    Juni, Peter
    Windecker, Stephan
    Pilgrim, Thomas
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2016, 5 (03):
  • [49] Comparison of biodegradable polymer biolimus-eluting stent versus durable polymer everolimus-eluting stent in terms of clinical outcome in patient with acute myocardial infarction
    Rhew, J. Y.
    Kim, W.
    Cho, J. H.
    Woo, J. S.
    Kim, H. S.
    EUROPEAN HEART JOURNAL, 2015, 36 : 823 - 823
  • [50] Real-World Experience With a Tapered Biodegradable Polymer-Coated Sirolimus-Eluting Stent in Patients With Long Coronary Artery Stenoses
    Lupi, Alessandro
    Ugo, Fabrizio
    De Martino, Leonardo
    Infantino, Vincenzo
    Iannaccone, Mario
    Iorio, Sergio
    Di Leo, Angelo
    Colangelo, Salvatore
    Zanera, Marco
    Schaffer, Alon
    Persampieri, Simone
    Garbo, Roberto
    Senatore, Gaetano
    CARDIOLOGY RESEARCH, 2020, 11 (04) : 219 - 225