Comparison of neointimal coverage between ultrathin biodegradable polymer-coated sirolimus-eluting stents and durable polymer-coated everolimus-eluting stents: 6 months optical coherence tomography follow-up from the TAXCO study

被引:11
|
作者
Abhyankar, Atul [1 ]
Abizaid, Alexandre [2 ]
Chamie, Daniel [3 ]
Rathod, Mihir [1 ]
机构
[1] Shree BD Mehta Mahavir Heart Inst, Dept Cardiol, Surat, Gujarat, India
[2] Univ Sao Paulo, Intervent Cardiol Dept, Sao Paulo, Brazil
[3] Dante Pazzanese Inst Cardiol, Invas Cardiol Dept, Sao Paulo, Brazil
关键词
coronary artery disease; drug-eluting stent; everolimus; percutaneous coronary intervention; sirolimus; PERCUTANEOUS CORONARY INTERVENTION; VASCULAR-RESPONSE; STRUT THICKNESS; THROMBOSIS; ANGIOGRAPHY; MECHANISMS; PATHOLOGY; IMPACT; RISK;
D O I
10.1002/ccd.28833
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim The TAXCO study was designed to compare the degree of neointimal coverage and the prevalence of malapposition at 6 months subsequent to implantation of ultrathin biodegradable polymer-coated sirolimus-eluting stents (SES) and durable polymer-coated everolimus-eluting stents (EES) of thin strut thickness using optical coherence tomography (OCT). Methods The TAXCO study included a total of 42 patients who gave consent and underwent OCT examination between August 2017 and September 2017. Of 42, five patients' OCT examinations were of insufficient quality for quantitative analysis. Thus, the OCT analysis group consisted of 37 patients. Among them, 16 patients were treated with Xience (Abbott Vascular) and 21 with Tetriflex (Sahajanand Medical Technologies Pvt. Ltd., Surat, India), 6 (+/- 1) months earlier at our institution. The OCT was performed using a C7 Dragonfly (TM) imaging catheter (St. Jude Medical Inc.). All OCT images were analyzed at an independent core laboratory (Cardiovascular Research Center, Sao Paulo, Brazil) by analysts who were blinded to patient and procedural information. Results A total of 763 crosssections (6,882 struts) were analyzed in Xience group, and 1,127 crosssections (9,968 struts) in Tetriflex group. At 6 months, on per-lesion basis, no significant differences were observed between Xience group and Tetriflex group in mean percentage of uncovered struts (1.87 +/- 3.86 vs. 2.42 +/- 3.46, p = .137) and malapposed struts (0.05 +/- 0.2 vs. 0.21 +/- 0.69, p = .302). Strut-level neointimal thickness also did not differ between Xience group and Tetriflex group (0.18 +/- 0.12 vs. 0.14 +/- 0.08 mm, p = .286). Conclusion This OCT study found no significant difference in strut coverage and neointimal thickness at 6 months after implantation of biodegradable polymer-coated Tetriflex, when compared with durable polymer-coated Xience.
引用
收藏
页码:423 / 430
页数:8
相关论文
共 50 条
  • [1] Biodegradable polymer-coated thin strut sirolimus-eluting stent versus durable polymer-coated everolimus-eluting stent in the diabetic population
    Gasior, Pawel
    Gierlotka, Marek
    Szczurek-Katanski, Krzysztof
    Osuch, Marcin
    Roleder, Magda
    Hawranek, Michal
    Wojakowski, Wojciech
    Polonski, Lech
    CARDIOLOGY JOURNAL, 2021, 28 (02) : 235 - 243
  • [2] An optical coherence tomography study of neointimal morphology and strut coverage at different time intervals from implantation of biodegradable polymer-coated sirolimus-eluting stents
    Legutko, Jacek
    Gil, Robert J.
    Buszman, Pawel E.
    Kaluza, Grzegorz L.
    Mintz, Gary S.
    Roleder, Tomasz
    Krol, Marek
    Wojdyla, Roman
    Pawlowski, Tomasz
    Brzezinski, Michal
    Kondys, Marek
    Skwarna, Bartosz
    Jakala, Jacek
    Zasada, Wojciech
    Partyka, Lukasz
    Dudek, Dariusz
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2018, 92 (02) : 302 - 309
  • [3] Ultrathin Bioresorbable Polymer Sirolimus-Eluting Stents Versus Durable Polymer Everolimus-Eluting Stents
    Kandzari, David E.
    Koolen, Jacques J.
    Doros, Gheorghe
    Garcia-Garcia, Hector M.
    Bennett, Johan
    Roguin, Ariel
    Gharib, Elie G.
    Cutlip, Donald E.
    Waksman, Ron
    JACC-CARDIOVASCULAR INTERVENTIONS, 2022, 15 (18) : 1852 - 1860
  • [4] Final five-year outcomes after implantation of biodegradable polymer-coated biolimus-eluting stents versus durable polymer-coated sirolimus-eluting stents
    Jakobsen, Lars
    Christiansen, Evald H.
    Maeng, Michael
    Hansen, Knud N.
    Kristensen, Steen D.
    Botker, Hans E.
    Terkelsen, Christian J.
    Jensen, Svend E.
    Raungaard, Bent
    Madsen, Morten
    Lassen, Jens F.
    Jensen, Lisette O.
    EUROINTERVENTION, 2017, 13 (11) : 1337 - 1345
  • [5] Comparison of Neointimal Coverage of Everolimus-Eluting Stents and Sirolimus-Eluting Stents: Optical Coherence Tomography Subanalysis from the RESET Trial
    Akasaka, Takashi
    Kubo, Takashi
    Nakagawa, Yoshihisa
    Igarashi, Keiichi
    Tanabe, Kengo
    Morino, Yoshihiro
    Iwabuchi, Masashi
    Kimura, Kazuo
    Kozuma, Ken
    Kimura, Takeshi
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (17) : B70 - B70
  • [6] Ultrathin Bioresorbable Polymer Sirolimus-Eluting Stents Versus Thin Durable Polymer Everolimus-Eluting Stents
    Kandzari, David E.
    Koolen, Jacques J.
    Doros, Gheorghe
    Massaro, Joseph J.
    Garcia-Garcia, Hector M.
    Bennett, Johan
    Roguin, Ariel
    Gharib, Elie G.
    Cutlip, Donald E.
    Waksman, Ron
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (25) : 3287 - 3297
  • [7] Twelve-month comparative analysis of clinical outcomes using biodegradable polymer-coated everolimus-eluting stents versus durable polymer-coated everolimus-eluting stents in all-comer patients
    Abhyankar, Atul
    Sandhu, Manjinder Singh
    Polavarapu, Raghava Sarma
    INDIAN HEART JOURNAL, 2019, 71 (02) : 149 - 154
  • [8] Comparison of neointimal coverage between everolimus-eluting stents and sirolimus-eluting stents: an optical coherence tomography substudy of the RESET (Randomized Evaluation of Sirolimus-eluting versus Everolimus-eluting stent Trial)
    Kubo, Takashi
    Akasaka, Takashi
    Kozuma, Ken
    Kimura, Kazuo
    Kawamura, Masaki
    Sumiyoshi, Tetsuya
    Ino, Yasushi
    Morino, Yoshihiro
    Tanabe, Kengo
    Kadota, Kazushige
    Kimura, Takeshi
    EUROINTERVENTION, 2015, 11 (05) : 564 - 571
  • [9] A Randomized Comparison of Novel Biodegradable Polymer- and Durable Polymer-Coated Cobalt-Chromium Sirolimus-Eluting Stents
    Han, Yaling
    Xu, Bo
    Jing, Quanmin
    Lu, Shuzheng
    Yang, Lixia
    Xu, Kai
    Li, Yi
    Li, Jing
    Guan, Changdong
    Kirtane, Ajay J.
    Yang, Yuejin
    JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (12) : 1352 - 1360
  • [10] Ex Vivo Shunt Thrombogenicity: A Comparison of XIENCE Everolimus-Eluting Stents to Contemporary Biodegradable Polymer-Coated Drug-Eluting Stents
    Otsuka, Fumiyuki
    Cheng, Qi
    Sheehy, Alexander
    Sakakura, Kenichi
    Yahagi, Kazuyuki
    Kutys, Robert
    Perkins, Laura E.
    Ladich, Elena
    Joner, Michael
    Kolodgie, Frank D.
    Virmani, Renu
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (11) : B127 - B128