Comparison of neointimal coverage between ultrathin biodegradable polymer-coated sirolimus-eluting stents and durable polymer-coated everolimus-eluting stents: 6 months optical coherence tomography follow-up from the TAXCO study

被引:11
|
作者
Abhyankar, Atul [1 ]
Abizaid, Alexandre [2 ]
Chamie, Daniel [3 ]
Rathod, Mihir [1 ]
机构
[1] Shree BD Mehta Mahavir Heart Inst, Dept Cardiol, Surat, Gujarat, India
[2] Univ Sao Paulo, Intervent Cardiol Dept, Sao Paulo, Brazil
[3] Dante Pazzanese Inst Cardiol, Invas Cardiol Dept, Sao Paulo, Brazil
关键词
coronary artery disease; drug-eluting stent; everolimus; percutaneous coronary intervention; sirolimus; PERCUTANEOUS CORONARY INTERVENTION; VASCULAR-RESPONSE; STRUT THICKNESS; THROMBOSIS; ANGIOGRAPHY; MECHANISMS; PATHOLOGY; IMPACT; RISK;
D O I
10.1002/ccd.28833
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim The TAXCO study was designed to compare the degree of neointimal coverage and the prevalence of malapposition at 6 months subsequent to implantation of ultrathin biodegradable polymer-coated sirolimus-eluting stents (SES) and durable polymer-coated everolimus-eluting stents (EES) of thin strut thickness using optical coherence tomography (OCT). Methods The TAXCO study included a total of 42 patients who gave consent and underwent OCT examination between August 2017 and September 2017. Of 42, five patients' OCT examinations were of insufficient quality for quantitative analysis. Thus, the OCT analysis group consisted of 37 patients. Among them, 16 patients were treated with Xience (Abbott Vascular) and 21 with Tetriflex (Sahajanand Medical Technologies Pvt. Ltd., Surat, India), 6 (+/- 1) months earlier at our institution. The OCT was performed using a C7 Dragonfly (TM) imaging catheter (St. Jude Medical Inc.). All OCT images were analyzed at an independent core laboratory (Cardiovascular Research Center, Sao Paulo, Brazil) by analysts who were blinded to patient and procedural information. Results A total of 763 crosssections (6,882 struts) were analyzed in Xience group, and 1,127 crosssections (9,968 struts) in Tetriflex group. At 6 months, on per-lesion basis, no significant differences were observed between Xience group and Tetriflex group in mean percentage of uncovered struts (1.87 +/- 3.86 vs. 2.42 +/- 3.46, p = .137) and malapposed struts (0.05 +/- 0.2 vs. 0.21 +/- 0.69, p = .302). Strut-level neointimal thickness also did not differ between Xience group and Tetriflex group (0.18 +/- 0.12 vs. 0.14 +/- 0.08 mm, p = .286). Conclusion This OCT study found no significant difference in strut coverage and neointimal thickness at 6 months after implantation of biodegradable polymer-coated Tetriflex, when compared with durable polymer-coated Xience.
引用
收藏
页码:423 / 430
页数:8
相关论文
共 50 条
  • [41] Five-year outcomes in patients with diabetes mellitus treated with biodegradable polymer sirolimus-eluting stents versus durable polymer everolimus-eluting stents
    Iglesias, J. F.
    Heg, D.
    Roffi, M.
    Tueller, D.
    Lanz, J.
    Rigamonti, F.
    Muller, O.
    Moarof, I.
    Cook, S.
    Weilenmann, D.
    Kaiser, C.
    Valgimigli, M.
    Jueni, P.
    Windecker, S.
    Pilgrim, T.
    EUROPEAN HEART JOURNAL, 2019, 40 : 1257 - 1257
  • [42] Efficacy and Safety of the Ultrathin Bioresorbable Polymer Sirolimus-Eluting Stents versus Thin Durable Polymer Everolimus-Eluting Stents for Treatment of Patients With Diabetes Mellitus
    Waksman, Ron
    Windecker, Stephan
    Koolen, Jacques J.
    Kandzari, David
    Saito, Shigeru
    Kolm, Paul
    Torguson, Rebecca
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (13) : B315 - B315
  • [43] Five-Year Outcomes in Patients With Diabetes Mellitus Treated With Biodegradable Polymer Sirolimus-Eluting Stents Versus Durable Polymer Everolimus-Eluting Stents
    Iglesias, Juan F.
    Heg, Dik
    Roffi, Marco
    Tuller, David
    Lanz, Jonas
    Rigamonti, Fabio
    Mueller, Olivier
    Moarof, Igal
    Cook, Stephane
    Weilenmann, Daniel
    Kaiser, Christoph
    Cuculi, Florim
    Valgimigli, Marco
    Juni, Peter
    Windecker, Stephan
    Pilgrim, Thomas
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2019, 8 (22):
  • [44] Long-term Vascular Response to Biodegradable Polymer Biolimus-Eluting Stents in Comparison With Durable Polymer Sirolimus-Eluting Stents and Bare-Metal Stents: Five-year Follow-up Optical Coherence Tomography Study
    Kuramitsu, Shoichi
    Sonoda, Shinjo
    Domei, Takenori
    Shirai, Shinichi
    Ando, Kenji
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (11) : B112 - B112
  • [45] Serial Changes of Neointimal Coverage Conditions and Characteristics are different between Sirolimus-Eluting Stents and Paclitaxel-Eluting Stents Implantation: Follow-Up Optical Coherence Tomography Study
    Nakamura, Daisuke
    Nishino, Masami
    Lee, Yasuharu
    Yoshimura, Takahiro
    Taniike, Masayuki
    Makino, Nobuhiko
    Kato, Hiroyasu
    Egami, Yasuyuki
    Shutta, Ryu
    Tanouchi, Jun
    Yamada, Yoshio
    CIRCULATION, 2011, 124 (21)
  • [46] Serial Changes of Neointimal Coverage Condition and Characteristic are Different between Sirolimus-Eluting Stents, Paclitaxel-Eluting Stents and Zotalolimus-Eluting Stents Implantation: Follow-Up Optical Coherence Tomography Study
    Nakamura, Daisuke
    Nishino, Masami
    Lee, Yasuharu
    Yoshimura, Takahiro
    Taniike, Masayuki
    Makino, Nobuhiko
    Kato, Hiroyasu
    Egami, Yasuyuki
    Shutta, Ryu
    Tanouchi, Jun
    Yamada, Yoshio
    CIRCULATION, 2011, 124 (21)
  • [47] A randomised comparison of biodegradable polymer- and permanent polymer-coated platinum-chromium everolimus-eluting coronary stents in China: the EVOLVE China study
    Han, Yaling
    Liu, Haiwei
    Yang, Yuejin
    Zhang, Jian
    Xu, Kai
    Fu, Guosheng
    Su, Xi
    Jiang, Tiemin
    Pang, Wenyue
    Chen, Jiyan
    Yuan, Zuyi
    Li, Hui
    Wang, Haichang
    Hong, Tao
    Liu, Huiliang
    Sun, Fucheng
    Allocco, Dominic J.
    Zhang, Mingdong
    Dawkins, Keith D.
    EUROINTERVENTION, 2017, 13 (10) : 1210 - 1217
  • [48] Ultrathin Strut Biodegradable Polymer-Coated Sirolimus-Eluting Coronary Stents: Patient-Level Pooled Analysis From Two Indian Registries
    Pothineni, Ramesh Babu
    Ajmera, Prakash
    Chawla, Kamal Kumar
    Mantravadi, Sai Sudhakar
    Pathak, Abhijit
    Inamdar, Manohar K.
    V. Jariwala, Pankaj
    Vijan, Vikrant
    Vijan, Vinod
    Potdar, Anil
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (07)
  • [49] Randomized comparison of biolimus-eluting stents with biodegradable polymer versus everolimus-eluting stents with permanent polymer coatings assessed by optical coherence tomography
    Tomohisa Tada
    Adnan Kastrati
    Robert A. Byrne
    Tibor Schuster
    Rezarta Cuni
    Lamin A. King
    Salvatore Cassese
    Michael Joner
    Jürgen Pache
    Steffen Massberg
    Albert Schömig
    Julinda Mehilli
    The International Journal of Cardiovascular Imaging, 2014, 30 : 495 - 504
  • [50] Randomized comparison of biolimus-eluting stents with biodegradable polymer versus everolimus-eluting stents with permanent polymer coatings assessed by optical coherence tomography
    Tada, Tomohisa
    Kastrati, Adnan
    Byrne, Robert A.
    Schuster, Tibor
    Cuni, Rezarta
    King, Lamin A.
    Cassese, Salvatore
    Joner, Michael
    Pache, Jurgen
    Massberg, Steffen
    Schoemig, Albert
    Mehilli, Julinda
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 (03): : 495 - 504