Iodide-selective polymeric membrane electrode based on copper(II) bis(N-2-bromophenylsalicyldenaminato) complex

被引:8
|
作者
Benvidi, Ali [1 ]
Ghanbarzadeh, M. T. [1 ]
Mazloum-Ardakani, Mohammad [1 ]
Vafazadeh, R. [1 ]
机构
[1] Yazd Univ, Dept Chem, Yazd, Iran
关键词
Iodide-selective electrode; Polymeric membrane; Potentimetry; CARRIER;
D O I
10.1016/j.cclet.2011.03.008
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A PVC membrane electrode based on copper(II) bis(N-2-bromophenylsalicyldenaminato) as ionophor was prepared. The ion selective electrode was tested by inorganic anions and showed a good selectivity for iodide ion. This sensor exhibited Nemstian behavior with a slope of -57.8 mV per decade at 25 degrees C. The proposed electrode showed a linear range from 1.0 x 10(-5) to 1.0 x 10(-1) mol/L with a detection limit of 5.0 x 10(-6) mol/L. The electrode response was independent of pH in the range of 3.0-10.0. The proposed sensor was applied to determine the iodide in water and antiseptic samples. (C) 2011 Ali Benvidi. Published by Elsevier B.V. on behalf of Chinese Chemical Society. All rights reserved.
引用
收藏
页码:1087 / 1090
页数:4
相关论文
共 50 条
  • [1] Iodide-selective polymeric membrane electrode based on copper(Ⅱ) bis(N-2-bromophenylsalicyldenaminato) complex
    Ali Benvidi
    M.T.Ghanbarzadeh
    M.Mazloum-Ardakani
    R.Vafazadeh
    Chinese Chemical Letters, 2011, 22 (09) : 1087 - 1090
  • [2] Iodide-Selective PVC Membrane Electrode Based on Copper Complex of 2-Acetylthiophene Semicarbazone as Carrier
    Suman, Shankar
    Singh, Ram
    ANALYTICAL CHEMISTRY LETTERS, 2020, 10 (03) : 357 - 365
  • [3] Iodide-selective electrode based on copper phthalocyanine
    Shahrokhian, S
    Taghani, A
    Moattar, F
    ELECTROANALYSIS, 2002, 14 (23) : 1621 - 1628
  • [4] Iodide-selective membrane electrode based on salophen complex of cobalt (III)
    Zare, HR
    Memarzadeh, F
    Gorji, A
    Mazloum-Ardakani, M
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2005, 16 (3B) : 571 - 577
  • [5] Copper(I)-bathocuproine complex as carrier in iodide-selective electrode
    Pouretedal, HR
    Keshavarz, MH
    TALANTA, 2004, 62 (01) : 223 - 227
  • [6] Design of Schiff base complexes of Co(II) for the preparation of iodide-selective polymeric membrane electrodes
    Yuan, R
    Song, YQ
    Chai, YQ
    Xia, SX
    Zhong, QY
    Yi, B
    Ying, M
    Shen, GL
    Yu, RQ
    TALANTA, 1999, 48 (03) : 649 - 657
  • [7] Highly selective iodide electrode based on the copper(II)-N,N′-bis(salicylidene)-1,2-bis(p-aminophenoxy)ethane tetradentate complex
    Xu, Wen-Ju
    Chai, Ya-Qin
    Yuan, Ruo
    Xu, Lan
    Liu, Su-Li
    ANALYTICAL SCIENCES, 2006, 22 (10) : 1345 - 1349
  • [8] Highly Selective Iodide Electrode Based on the Copper(II)-N,N′-bis(salicylidene)-1,2-bis(p-aminophenoxy)ethane Tetradentate Complex
    Wen-Ju Xu
    Ya-Qin Chai
    Ruo Yuan
    Lan Xu
    Su-Li Liu
    Analytical Sciences, 2006, 22 : 1345 - 1349
  • [9] A selective membrane electrode for salicylate ion based on a bis-salicylaldoxime complex of copper(II) as ionophore
    Wang Fuchang
    Chai Yaqin
    Yuan Ruo
    Gui Guofeng
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 34 (05) : 725 - 728
  • [10] Perchlorate-selective polymeric membrane electrode based on bis(dibenzoylmethanato)cobalt(II) complex as a neutral carrier
    Rezaei, Behzad
    Meghdadi, Soraia
    Bagherpour, Saeid
    JOURNAL OF HAZARDOUS MATERIALS, 2009, 161 (2-3) : 641 - 648