Iodide-selective polymeric membrane electrode based on copper(II) bis(N-2-bromophenylsalicyldenaminato) complex

被引:8
|
作者
Benvidi, Ali [1 ]
Ghanbarzadeh, M. T. [1 ]
Mazloum-Ardakani, Mohammad [1 ]
Vafazadeh, R. [1 ]
机构
[1] Yazd Univ, Dept Chem, Yazd, Iran
关键词
Iodide-selective electrode; Polymeric membrane; Potentimetry; CARRIER;
D O I
10.1016/j.cclet.2011.03.008
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A PVC membrane electrode based on copper(II) bis(N-2-bromophenylsalicyldenaminato) as ionophor was prepared. The ion selective electrode was tested by inorganic anions and showed a good selectivity for iodide ion. This sensor exhibited Nemstian behavior with a slope of -57.8 mV per decade at 25 degrees C. The proposed electrode showed a linear range from 1.0 x 10(-5) to 1.0 x 10(-1) mol/L with a detection limit of 5.0 x 10(-6) mol/L. The electrode response was independent of pH in the range of 3.0-10.0. The proposed sensor was applied to determine the iodide in water and antiseptic samples. (C) 2011 Ali Benvidi. Published by Elsevier B.V. on behalf of Chinese Chemical Society. All rights reserved.
引用
收藏
页码:1087 / 1090
页数:4
相关论文
共 50 条
  • [41] Polymeric lead(II)-selective electrode based on N,N′-bis-thiophen-2-ylmethylene-pyridine-2,6-diamine as an ion carrier
    Kim, Heecheol
    Lee, Hyo Kyoung
    Choi, A. Young
    Jeon, Seungwon
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2007, 28 (04) : 538 - 542
  • [42] Research and Application of Thiocyanate-Selective Polyviny Chloride Membrane Electrode Based on Copper(II) Complex with 2-Amino-Thiourea-Bis(Salicylaldehyde) Base as Carrier
    Liu Huo-An
    Xu Gang
    Ren Ling-Yan
    Dong Wen-Li
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (12) : 1801 - 1804
  • [43] A fast response hafnium selective polymeric membrane electrode based on N,N′-bis(α-methyl-salicylidene)-dipropylenetriamine as a neutral carrier
    Rezaei, B.
    Meghdadi, S.
    Zarandi, R. Fazel
    JOURNAL OF HAZARDOUS MATERIALS, 2008, 157 (01) : 18 - 24
  • [44] Cd (II) Ion-Selective Electrode Based On 2-Acetylthiophene Semicarbazone In Polymeric Membrane
    Mohan, C.
    Sharma, K.
    Chandra, S.
    CHEMICAL SENSORS 12: CHEMICAL AND BIOLOGICAL SENSORS AND ANALYTICAL SYSTEMS, 2016, 75 (16): : 319 - 327
  • [45] Zinc(II) Selective Electrode based on Polymeric Membrane of 2,6-Diacetylpyridinebis(benzenesulfonylhydrazide) Ligand
    Isa, Illyas Md
    Noor, Safura Mohd
    Juahir, Yusnita
    Hashim, Norhayati
    Ahmad, Mustaffa
    Kamari, Azlan
    Mohamed, Azmi
    Ab Ghani, Sazelli
    Wardani, Nur Indah
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (08): : 4512 - 4522
  • [46] Thiocyanate ion selective electrode based on bis(N-3-methylphenyl salicylidenaminato)copper(II) ionophore
    Benvidi, A.
    Ghanbarzadeh, M. T.
    Dehghan, M.
    Mazloum-Ardakani, M.
    Vafazadeh, R.
    CHINESE CHEMICAL LETTERS, 2014, 25 (12) : 1639 - 1642
  • [47] A lead (II)-selective PVC membrane based on a Schiff base complex of N,N'-bis(salicylidene)-2,6-pyridinediamine
    Jeong, T
    Lee, HK
    Jeong, DC
    Jeon, S
    TALANTA, 2005, 65 (02) : 543 - 548
  • [48] Highly copper(II)-selective PVC membrane based on a Schiff base complex of N,N′-bis-pyridin-2-ylmethylene-naphthalene-1,8-diamine as an ionophore
    Jeong, Dae-Cheol
    Lee, Hyo Kyoung
    Jeon, Seungwon
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2006, 27 (10) : 1593 - 1596
  • [49] Copper(II)-selective membrane electrode based on a recently synthesized macrocyclic diamide
    Shamsipur, M
    Rouhani, S
    Ganjali, MR
    Eshghi, H
    Sharghi, H
    MICROCHEMICAL JOURNAL, 1999, 63 (02) : 202 - 210
  • [50] Highly selective thiocyanate electrode based on bis-bebzoin-semitriethylenetetraamine binuclear copper(II) complex as neutral carrier
    Yuan, R
    Wang, XL
    Xu, L
    Chai, YQ
    Sun, ZY
    Huang, XQ
    Li, QF
    Zhao, Q
    Zhou, L
    ELECTROCHEMISTRY COMMUNICATIONS, 2003, 5 (08) : 717 - 721