Iodide-selective polymeric membrane electrode based on copper(II) bis(N-2-bromophenylsalicyldenaminato) complex

被引:8
|
作者
Benvidi, Ali [1 ]
Ghanbarzadeh, M. T. [1 ]
Mazloum-Ardakani, Mohammad [1 ]
Vafazadeh, R. [1 ]
机构
[1] Yazd Univ, Dept Chem, Yazd, Iran
关键词
Iodide-selective electrode; Polymeric membrane; Potentimetry; CARRIER;
D O I
10.1016/j.cclet.2011.03.008
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A PVC membrane electrode based on copper(II) bis(N-2-bromophenylsalicyldenaminato) as ionophor was prepared. The ion selective electrode was tested by inorganic anions and showed a good selectivity for iodide ion. This sensor exhibited Nemstian behavior with a slope of -57.8 mV per decade at 25 degrees C. The proposed electrode showed a linear range from 1.0 x 10(-5) to 1.0 x 10(-1) mol/L with a detection limit of 5.0 x 10(-6) mol/L. The electrode response was independent of pH in the range of 3.0-10.0. The proposed sensor was applied to determine the iodide in water and antiseptic samples. (C) 2011 Ali Benvidi. Published by Elsevier B.V. on behalf of Chinese Chemical Society. All rights reserved.
引用
收藏
页码:1087 / 1090
页数:4
相关论文
共 50 条
  • [21] Theoretical and practical investigations of copper ion selective electrode with polymeric membrane based on N,N′-(2,2-dimethylpropane-1,3-diyl)-bis(dihydroxyacetophenone)
    Ghanei-Motlagh, Masoud
    Taher, Mohammad Ali
    Saheb, Vahid
    Fayazi, Maryam
    Sheikhshoaie, Iran
    ELECTROCHIMICA ACTA, 2011, 56 (15) : 5376 - 5385
  • [23] Copper Ion Selective Membrane Electrode Based on Bis(salphenH2) Derivatives
    Lee, Chaegyung
    Kim, Dong Wan
    Kim, Junghwan
    Yang, Mi-Hyi
    Choi, Myong Yong
    Kim, Jae Sang
    SENSOR LETTERS, 2010, 8 (02) : 297 - 302
  • [24] Highly selective thiocyanate electrode based on bis-[N-(2-hydroxyethyl)salicylaldimino]copper(II) complex as a neutral carrier
    Huang, XQ
    Chai, YQ
    Yuan, R
    Wang, XL
    Li, QF
    ANALYTICAL SCIENCES, 2004, 20 (08) : 1185 - 1188
  • [25] Highly Selective Thiocyanate Electrode Based on Bis-[N-(2-hydroxyethyl)salicylaldimino]copper(II) Complex as a Neutral Carrier
    Xiaoqing Huang
    Yaqin Chai
    Ruo Yuan
    Xiuling Wang
    Qunfang Li
    Analytical Sciences, 2004, 20 : 1185 - 1188
  • [26] Iodide-selective electrodes based on the silver(I) complex of a novel N-thiocarbamoylimine-dithioether derivative
    ElAamrani, FZ
    Sastre, A
    Aguilar, M
    Beyer, L
    Florido, A
    ANALYTICA CHIMICA ACTA, 1996, 329 (03) : 247 - 252
  • [27] Highly thiocyanate-selective membrane electrode based on the bis(benzoylacetone) propylenedimine copper(h) complex
    Rezaei, Behzad
    Meghdadi, Soraya
    Nafisi, Vajihe
    Bagherpour, Saeid
    ANNALI DI CHIMICA, 2007, 97 (11-12) : 1191 - 1205
  • [28] HIGHLY SENSITIVE MEMBRANE ELECTRODE BASED ON A COPPER(II)-BIS(N-4-METHYLPHENYL-SALICYLDENAMINATO) COMPLEX FOR THE DETERMINATION OF CHROMATE
    Benvidi, Ali
    Elahizadeh, Mehdi
    Zare, Hamid R.
    Vafazadeh, Rasoul
    ANALYTICAL LETTERS, 2011, 44 (04) : 595 - 606
  • [29] Iodide-selective electrodes based on bis[N(2-methyl-phenyl) 4-nitro-thiobenzamidato]mercury(II) and bis[N-phenyl 3,5-dinitro-thiobenzamidato]mercury(II) carriers
    Ghaedi, M
    Shojaie, AF
    Montazerozohori, M
    Karami, B
    Gharaghani, S
    ELECTROANALYSIS, 2005, 17 (19) : 1746 - 1754
  • [30] Highly selective iodide poly(vinyl chloride) membrane electrode based on a nickel(II) tetraazaannulene macrocyclic complex
    Ying, M
    Yuan, R
    Zhang, XM
    Song, YQ
    Li, ZQ
    Shen, GL
    Yu, RQ
    ANALYST, 1997, 122 (10) : 1143 - 1146