Iodide-selective polymeric membrane electrode based on copper(II) bis(N-2-bromophenylsalicyldenaminato) complex

被引:8
|
作者
Benvidi, Ali [1 ]
Ghanbarzadeh, M. T. [1 ]
Mazloum-Ardakani, Mohammad [1 ]
Vafazadeh, R. [1 ]
机构
[1] Yazd Univ, Dept Chem, Yazd, Iran
关键词
Iodide-selective electrode; Polymeric membrane; Potentimetry; CARRIER;
D O I
10.1016/j.cclet.2011.03.008
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A PVC membrane electrode based on copper(II) bis(N-2-bromophenylsalicyldenaminato) as ionophor was prepared. The ion selective electrode was tested by inorganic anions and showed a good selectivity for iodide ion. This sensor exhibited Nemstian behavior with a slope of -57.8 mV per decade at 25 degrees C. The proposed electrode showed a linear range from 1.0 x 10(-5) to 1.0 x 10(-1) mol/L with a detection limit of 5.0 x 10(-6) mol/L. The electrode response was independent of pH in the range of 3.0-10.0. The proposed sensor was applied to determine the iodide in water and antiseptic samples. (C) 2011 Ali Benvidi. Published by Elsevier B.V. on behalf of Chinese Chemical Society. All rights reserved.
引用
收藏
页码:1087 / 1090
页数:4
相关论文
共 50 条
  • [31] XYLENE BIS(DIETHYLDITHIOCARBAMATE) AS A NEUTRAL CARRIER FOR COPPER(II)-SELECTIVE MEMBRANE-ELECTRODE
    KAMATA, S
    OGAWA, F
    FUKUMOTO, M
    CHEMISTRY LETTERS, 1987, (03) : 533 - 534
  • [32] Copper(II) ion selective PVC membrane electrode based on S,S′-bis(2-aminophenyl)ethanebis(thioate)
    Buzuk, Marijo
    Brinic, Slobodan
    Generalic, Eni
    Bralic, Marija
    CROATICA CHEMICA ACTA, 2009, 82 (04) : 801 - 806
  • [33] Highly thiocyanate-selective membrane electrodes based on the N,N′-bis-(benzaldehyde)-glycine copper(II) complex as a neutral carrier
    Chai, YQ
    Dai, JY
    Yuan, R
    Zhong, X
    Liu, Y
    Tang, DP
    DESALINATION, 2005, 180 (1-3) : 207 - 215
  • [34] Thiocyanate-selective electrode based on N-salicylidene-benzylamineato copper(II) complex
    Wang, F. C.
    Chai, Y. Q.
    Yuan, R.
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2008, 44 (03) : 272 - 277
  • [35] Thiocyanate-selective electrode based on N-salicylidene-benzylamineato copper(II) complex
    F. C. Wang
    Y. Q. Chai
    R. Yuan
    Russian Journal of Electrochemistry, 2008, 44 : 272 - 277
  • [36] Nitrate Selective Polymeric Membrane Electrode Based on Bis-Thiourea Ligand as Carrier
    Rawat, Aruna
    Chandra, Sulekh
    Sarkar, Anjana
    SENSOR LETTERS, 2009, 7 (06) : 1100 - 1105
  • [37] ANION-SELECTIVE MEMBRANE-ELECTRODE BASED ON BIS(DIPHENYLPHOSPHINO)ALKANE-COPPER(II) COMPLEXES
    KAMATA, S
    NOMURA, S
    OHASHI, K
    BUNSEKI KAGAKU, 1990, 39 (11) : 677 - 681
  • [38] Thiocyanate-selective PVC membrane electrode based on tricoordinate Schiff base copper(II) complex
    Dai, JY
    Chai, YQ
    Yuan, R
    Zhang, YS
    Liu, Y
    Zhong, X
    Tang, DP
    CHEMISTRY LETTERS, 2005, 34 (01) : 62 - 63
  • [39] Iodide-selective PVC membrane electrodes based on five transitional metal chelates of bis-furfural-semi-o-tolidine
    Li, ZQ
    Yuan, R
    Ying, M
    Song, YQ
    Shen, GL
    Yu, RQ
    ANALYTICAL LETTERS, 1997, 30 (08) : 1455 - 1464
  • [40] Iodide ion-selective PVC membrane electrode based on a recently synthesized salen-Mn(II) complex
    Shamsipur, M
    Sadeghi, S
    Naeimi, H
    Sharghi, H
    POLISH JOURNAL OF CHEMISTRY, 2000, 74 (02) : 231 - 238