Iodide-Selective PVC Membrane Electrode Based on Copper Complex of 2-Acetylthiophene Semicarbazone as Carrier

被引:3
|
作者
Suman, Shankar [1 ]
Singh, Ram [1 ]
机构
[1] Delhi Technol Univ, Dept Appl Chem, Delhi 10042, India
关键词
Iodide-selective electrode; potentiometric sensor; copper (II) complex; 2-acetyl thiophene semicarbazone; PVC; SENSOR; DIBENZO-24-CROWN-8;
D O I
10.1080/22297928.2020.1788989
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A highly selective poly(vinyl chloride) (PVC) membrane electrode based on copper (II) complex of 2-acetylthiophene semicarbazone as a new carrier for iodide-selective electrode is fabricated with the composition of PVC (30 %), plasticizer (64 %), ionophore (4 %) and lipophilic additive (2 %). The prepared electrode has been found to exhibit the best sensitivity over a wide concentration range of 1x10(-6) to 3.2x10(-2) M with a near Nernstian response of 57.2 mV per decade over a wide pH range of 2.5 - 10.5. The detection limit for the electrode was found to be 5.50x10(-7) M with the response time of 15 s and can be used for at least 3 months without any considerable divergence in its potential response.
引用
收藏
页码:357 / 365
页数:9
相关论文
共 50 条
  • [1] Cd (II) Ion-Selective Electrode Based On 2-Acetylthiophene Semicarbazone In Polymeric Membrane
    Mohan, C.
    Sharma, K.
    Chandra, S.
    CHEMICAL SENSORS 12: CHEMICAL AND BIOLOGICAL SENSORS AND ANALYTICAL SYSTEMS, 2016, 75 (16): : 319 - 327
  • [2] Copper(I)-bathocuproine complex as carrier in iodide-selective electrode
    Pouretedal, HR
    Keshavarz, MH
    TALANTA, 2004, 62 (01) : 223 - 227
  • [3] Iodide-selective polymeric membrane electrode based on copper(Ⅱ) bis(N-2-bromophenylsalicyldenaminato) complex
    Ali Benvidi
    M.T.Ghanbarzadeh
    M.Mazloum-Ardakani
    R.Vafazadeh
    Chinese Chemical Letters, 2011, 22 (09) : 1087 - 1090
  • [4] Iodide-selective electrode based on copper phthalocyanine
    Shahrokhian, S
    Taghani, A
    Moattar, F
    ELECTROANALYSIS, 2002, 14 (23) : 1621 - 1628
  • [5] Iodide-selective polymeric membrane electrode based on copper(II) bis(N-2-bromophenylsalicyldenaminato) complex
    Benvidi, Ali
    Ghanbarzadeh, M. T.
    Mazloum-Ardakani, Mohammad
    Vafazadeh, R.
    CHINESE CHEMICAL LETTERS, 2011, 22 (09) : 1087 - 1090
  • [6] Iodide-selective membrane electrode based on salophen complex of cobalt (III)
    Zare, HR
    Memarzadeh, F
    Gorji, A
    Mazloum-Ardakani, M
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2005, 16 (3B) : 571 - 577
  • [7] NEW MEMBRANE ELECTRODE SYSTEM WITH IODIDE-SELECTIVE PROPERTIES
    NOVKIRISHKA, M
    CHRISTOVA, R
    ANALYTICA CHIMICA ACTA, 1975, 78 (01) : 63 - 68
  • [8] Fabrication of copper-selective PVC membrane electrode based on newly synthesized copper complex of Schiff base as carrier
    Chandra, Sulekh
    Tomar, Praveen Kumar
    Kumar, Avdhesh
    Malik, Amrita
    Singh, Arendra
    JOURNAL OF SAUDI CHEMICAL SOCIETY, 2016, 20 : S293 - S299
  • [9] Lead(II) Selective PVC Membrane Electrode Based on Zinc Complex of Salicylaldehyde Semicarbazone as an Ionophore ZSSC
    Chandra, Sulekh
    Sharma, Kusum
    Kumar, Adarsh
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2010, 2 (03): : 125 - 138
  • [10] Triphenyllead chloride as a new ionophore for an iodide-selective membrane electrode
    Katsu, T