Fabrication of copper-selective PVC membrane electrode based on newly synthesized copper complex of Schiff base as carrier

被引:6
|
作者
Chandra, Sulekh [1 ]
Tomar, Praveen Kumar [1 ]
Kumar, Avdhesh [1 ]
Malik, Amrita [1 ]
Singh, Arendra [1 ]
机构
[1] Univ Delhi, Dept Chem, Zakir Husain Delhi Coll, JL Nehru Marg, New Delhi 110002, India
关键词
Poly(vinyl chloride); Nernstian slope; Copper(II)-selective electrode; Schiff base complex; Potentiometry; LIQUID-CHROMATOGRAPHY; SENSORS; MERCURY; NICKEL; TRACE;
D O I
10.1016/j.jscs.2012.11.010
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The newly synthesized copper(II) complex of Schiff base p-hydroxyacetophenone semicarbazone was explored as neutral ionophore for the fabrication of poly(vinylchloride) (PVC) based membrane electrode selective to Cu(II) ions. The electrode shows a Nernstian slope of 29.8 +/- 0.3 mV/decade with improved linear range of 1.8 x 10(-7) to 1.0 x 10(-1) M, comparatively lower detection limit 5.7 x 10(-8) M between pH range of 2.0-8.0, giving a relatively fast response within 5s and can be used for at least 16 weeks without any divergence in potential. The selectivity coefficient was calculated using the fixed interference method (FIM). The electrode can also be used in partially non-aqueous media having up to 25% (v/v) methanol, ethanol or acetone content with no significant change in the value of slope or working concentration range. It was successfully applied for the direct determination of copper content in water and tea samples with satisfactory results. The electrode has been used in the potentiometric titration of Cu2+ with EDTA. (C) 2012 Production and hosting by Elsevier B.V. on behalf of King Saud University. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:S293 / S299
页数:7
相关论文
共 50 条
  • [1] Fabrication of PVC Membrane Based Ion Selective Electrode by Using the Newly Synthesised Copper Schiff Base Complex
    Swami, Babu Lal
    Tyagi, Sonika
    Ahmed, Shakeel
    Ikram, Saiqa
    MATERIALS FOCUS, 2015, 4 (03) : 179 - 183
  • [2] Thiocyanate-selective PVC membrane electrode based on tricoordinate Schiff base copper(II) complex
    Dai, JY
    Chai, YQ
    Yuan, R
    Zhang, YS
    Liu, Y
    Zhong, X
    Tang, DP
    CHEMISTRY LETTERS, 2005, 34 (01) : 62 - 63
  • [3] Copper-Selective PVC Membrane Sensor
    Ganjali, Mohammad Reza
    Ghafarloo, Ali
    Faridbod, Farnoush
    Norouzi, Parviz
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (04): : 3706 - 3716
  • [4] Highly selective and sensitive copper membrane electrode based on a new synthesized Schiff base
    Gholivand, M. B.
    Rahimi-Nasrabadi, M.
    Ganjali, M. R.
    Salavati-Niasari, M.
    TALANTA, 2007, 73 (03) : 553 - 560
  • [5] Novel copper(II)-selective membrane electrode based on a new synthesized Schiff base
    Akhond, Morteza
    Najafi, Mohammad Bagher
    Sharghi, Hashem
    Tashkhourian, Javad
    Naiemi, Hossein
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2007, 54 (02) : 331 - 337
  • [6] Copper(II) ion selective electrode based on a newly synthesized Schiff-base chelate
    Jain, Ajay Kumar
    Singh, Raj Kumar
    Jain, Shalabh
    Raisoni, Jitendra
    TRANSITION METAL CHEMISTRY, 2008, 33 (02) : 243 - 249
  • [7] Copper(II) ion selective electrode based on a newly synthesized Schiff-base chelate
    Ajay Kumar Jain
    Raj Kumar Singh
    Shalabh Jain
    Jitendra Raisoni
    Transition Metal Chemistry, 2008, 33 : 243 - 249
  • [8] Copper (II) ion selective liquid membrane electrode based on new Schiff base carrier
    Sadeghi, S
    Vardini, MT
    Naeimi, H
    ANNALI DI CHIMICA, 2006, 96 (1-2) : 65 - 74
  • [9] Copper-selective PVC membrane electrodes based on salens as carriers
    Fakhari, AR
    Raji, TA
    Naeimi, H
    SENSORS AND ACTUATORS B-CHEMICAL, 2005, 104 (02) : 317 - 323
  • [10] Highly Selective Perchlorate Membrane Electrode Based on Synthesized Schiff Base Complex
    Mazloum-Ardakani, Mohammad
    Mazidi, Roya
    Mashhadizadeh, Mohammad Hossein
    Naeimi, Hossein
    Rabiei, Kobra
    IRANIAN JOURNAL OF CHEMISTRY & CHEMICAL ENGINEERING-INTERNATIONAL ENGLISH EDITION, 2010, 29 (03): : 123 - 132