Fabrication of copper-selective PVC membrane electrode based on newly synthesized copper complex of Schiff base as carrier

被引:6
|
作者
Chandra, Sulekh [1 ]
Tomar, Praveen Kumar [1 ]
Kumar, Avdhesh [1 ]
Malik, Amrita [1 ]
Singh, Arendra [1 ]
机构
[1] Univ Delhi, Dept Chem, Zakir Husain Delhi Coll, JL Nehru Marg, New Delhi 110002, India
关键词
Poly(vinyl chloride); Nernstian slope; Copper(II)-selective electrode; Schiff base complex; Potentiometry; LIQUID-CHROMATOGRAPHY; SENSORS; MERCURY; NICKEL; TRACE;
D O I
10.1016/j.jscs.2012.11.010
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The newly synthesized copper(II) complex of Schiff base p-hydroxyacetophenone semicarbazone was explored as neutral ionophore for the fabrication of poly(vinylchloride) (PVC) based membrane electrode selective to Cu(II) ions. The electrode shows a Nernstian slope of 29.8 +/- 0.3 mV/decade with improved linear range of 1.8 x 10(-7) to 1.0 x 10(-1) M, comparatively lower detection limit 5.7 x 10(-8) M between pH range of 2.0-8.0, giving a relatively fast response within 5s and can be used for at least 16 weeks without any divergence in potential. The selectivity coefficient was calculated using the fixed interference method (FIM). The electrode can also be used in partially non-aqueous media having up to 25% (v/v) methanol, ethanol or acetone content with no significant change in the value of slope or working concentration range. It was successfully applied for the direct determination of copper content in water and tea samples with satisfactory results. The electrode has been used in the potentiometric titration of Cu2+ with EDTA. (C) 2012 Production and hosting by Elsevier B.V. on behalf of King Saud University. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:S293 / S299
页数:7
相关论文
共 50 条
  • [31] A schiff base complex of Zn(II) as a neutral carrier for highly selective PVC membrane sensors for the sulfate ion
    Shamsipur, M
    Yousefi, M
    Hosseini, M
    Ganjali, MR
    Sharghi, H
    Naeimi, H
    ANALYTICAL CHEMISTRY, 2001, 73 (13) : 2869 - 2874
  • [32] A PVC MATRIX MEMBRANE COPPER ION-SELECTIVE ELECTRODE BASED ON A MACROCYCLIC POLYTHIAETHER
    KAMATA, S
    HIGO, M
    KAMIBEPPU, T
    TANAKA, I
    CHEMISTRY LETTERS, 1982, (03) : 287 - 288
  • [33] Aluminium(III)-selective electrode based on a newly synthesized glyoxal-bis-thiosemicarbazone Schiff base
    Y. Li
    Y. Chai
    R. Yuan
    W. Liang
    L. Zhang
    G. Ye
    Journal of Analytical Chemistry, 2008, 63
  • [34] Aluminium(III)-Selective Electrode Based on a Newly Synthesized Glyoxal-bis-Thiosemicarbazone Schiff Base
    Li, Y.
    Chai, Y.
    Yuan, R.
    Liang, W.
    Zhang, L.
    Ye, G.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2008, 63 (11) : 1090 - 1093
  • [35] Unsymmetrical tetradentate Schiff bases copper (II) complex as neutral carrier for thiocyanate-selective electrode
    Luo, E. -P.
    Chai, Y. -Q.
    Yuan, R.
    ANALYTICAL LETTERS, 2007, 40 (02) : 369 - 386
  • [36] Highly Selective Perchlorate Membrane Electrode Based on Cobalt(III) Schiff Base as a Neutral Carrier
    Shokrollahi, Ardeshir
    Ghaedi, Mehrorang
    Rajabi, Hamid Reza
    Kianfar, Ali Hossein
    CHINESE JOURNAL OF CHEMISTRY, 2009, 27 (02) : 258 - 266
  • [37] Thiocyanate-selective membrane electrode based on cobalt(III) Schiff base as a charge carrier
    Shokrollahi, Ardeshir
    Ghaedi, Mehrorang
    Ghaedi, Hamed
    Kianfar, Ali Hossein
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2008, 88 (12) : 841 - 856
  • [38] New Pb(II)-selective membrane electrode based on a new Schiff base complex
    Yuan, Xiao-Ju
    Wang, Rui-Ying
    Mao, Chun-Bo
    Wu, Lian
    Chu, Cai-Qing
    Yao, Rui
    Gao, Zhi-Yang
    Wu, Ben-Lai
    Zhang, Hong-Yun
    INORGANIC CHEMISTRY COMMUNICATIONS, 2012, 15 : 29 - 32
  • [39] Iodide Selective Electrode Based on Cobalt (II) Complex with Unsymmetrical Schiff Base as Neutral Carrier
    Xu Gang
    Yuan Ruo
    Chai Ya-Qin
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2008, 36 (08) : 1101 - 1104
  • [40] Highly Selective and Sensitive Tin(II) Membrane Electrode Based on a New Synthesized Schiff's Base
    Hosseini, Morteza
    Sadeghi, Hayedeh Bagheri
    Rahimi, Mohammad
    Salavati-Niasari, Masoud
    Abkenar, Shiva Dehghan
    Alizadeh, Kamal
    Ganjali, Mohammad Reza
    ELECTROANALYSIS, 2009, 21 (07) : 859 - 866