Perchlorate-selective polymeric membrane electrode based on bis(dibenzoylmethanato)cobalt(II) complex as a neutral carrier

被引:27
|
作者
Rezaei, Behzad [1 ]
Meghdadi, Soraia [1 ]
Bagherpour, Saeid [1 ]
机构
[1] Isfahan Univ Technol, Dept Chem, Esfahan 8415683111, Iran
关键词
Ion-selective electrode; Bis(dibenzoylmethanato)cobalt(II); Perchlorate; Poly(vinyl chloride); ION CHROMATOGRAPHY; DRINKING-WATER; ANION; LEVEL; EXTRACTION; ADDITIVES; NITRATE;
D O I
10.1016/j.jhazmat.2008.04.005
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A synthesized bis(dibenzoylmethanato)Co(II) complex (Co(DBM)(2)), has been used as a ionophore for the preparation of a new perchlorate ion-selective electrode. The electrode exhibits a Nernstian response over the perchlorate concentration range of 8.0 x 10(-7) -1.0 x 10(-1) M with a slope of 60.3 +/- 0.5 mV per decade of concentration. The limit of detection as determined from the intersection of the extrapolated linear segments of the calibration plot is 5.6 x 10(-7) M. The electrode shows good selectivity towards perchlorate with respect to many common anions. The response time of the sensor is very fast (<= 5 5), and can be used for at least 2 months in the pH range of 2.0-9.0. The electrode was used to determine perchlorate in water and human urine. The interaction of the ionophore with perchlorate ions was demonstrated by UV-vis spectroscopy. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:641 / 648
页数:8
相关论文
共 50 条
  • [1] Fast response and selective perchlorate polymeric membrane electrode based on bis(dibenzoylmethanato) nickel(II) complex as a neutral carrier
    Rezaei, B.
    Meghdadi, S.
    Nafisi, V.
    SENSORS AND ACTUATORS B-CHEMICAL, 2007, 121 (02) : 600 - 605
  • [2] Perchlorate-selective polymeric membrane electrode based on a cobaloxime as a suitable carrier
    Zanjanchi, MA
    Arvand, M
    Akbari, M
    Tabatabaeian, K
    Zaraei, G
    SENSORS AND ACTUATORS B-CHEMICAL, 2006, 113 (01): : 304 - 309
  • [3] Perchlorate-selective membrane electrode based on a new complex of uranil
    M. Mazloum Ardakani
    M. Jalayer
    H. Naeimi
    H. R. Zare
    L. Moradi
    Analytical and Bioanalytical Chemistry, 2005, 381 : 1186 - 1192
  • [4] Perchlorate-selective membrane electrode based on a new complex of uranil
    Mazloum-Ardakani, M
    Jalayer, M
    Naeimi, H
    Zare, HR
    Moradi, L
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 381 (06) : 1186 - 1192
  • [5] Perchlorate-selective polymeric membrane electrode based on a gold(I) complex:: application to water and urine analysis
    Sánchez-Pedreño, C
    Ortuño, JA
    Hernández, J
    ANALYTICA CHIMICA ACTA, 2000, 415 (1-2) : 159 - 164
  • [6] Complex of Co(III) as Receptor Molecule for Development of a New Perchlorate-Selective Polymeric Membrane Electrode
    Zarei, Goldasthe
    Zonouzi, Foroozan
    ASIAN JOURNAL OF CHEMISTRY, 2009, 21 (09) : 6819 - 6826
  • [7] Highly Selective Perchlorate Membrane Electrode Based on Cobalt(III) Schiff Base as a Neutral Carrier
    Shokrollahi, Ardeshir
    Ghaedi, Mehrorang
    Rajabi, Hamid Reza
    Kianfar, Ali Hossein
    CHINESE JOURNAL OF CHEMISTRY, 2009, 27 (02) : 258 - 266
  • [8] LIQUID-MEMBRANE PERCHLORATE-SELECTIVE ELECTRODE
    JAIN, AK
    JAHAN, M
    TYAGI, V
    ANALYST, 1987, 112 (10) : 1355 - 1357
  • [9] Iodide Selective Electrode Based on Cobalt (II) Complex with Unsymmetrical Schiff Base as Neutral Carrier
    Xu Gang
    Yuan Ruo
    Chai Ya-Qin
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2008, 36 (08) : 1101 - 1104
  • [10] A highly selective polymeric membrane barium(II) electrode based on a macrocyclic tetrabasic ligand as neutral carrier
    Yu-Hua Ma
    Ruo Yuan
    Ya-Qin Chai
    Xin-Lu Liu
    Analytical and Bioanalytical Chemistry, 2009, 395 : 855 - 862