共 50 条
Perchlorate-selective polymeric membrane electrode based on bis(dibenzoylmethanato)cobalt(II) complex as a neutral carrier
被引:27
|作者:
Rezaei, Behzad
[1
]
Meghdadi, Soraia
[1
]
Bagherpour, Saeid
[1
]
机构:
[1] Isfahan Univ Technol, Dept Chem, Esfahan 8415683111, Iran
关键词:
Ion-selective electrode;
Bis(dibenzoylmethanato)cobalt(II);
Perchlorate;
Poly(vinyl chloride);
ION CHROMATOGRAPHY;
DRINKING-WATER;
ANION;
LEVEL;
EXTRACTION;
ADDITIVES;
NITRATE;
D O I:
10.1016/j.jhazmat.2008.04.005
中图分类号:
X [环境科学、安全科学];
学科分类号:
08 ;
0830 ;
摘要:
A synthesized bis(dibenzoylmethanato)Co(II) complex (Co(DBM)(2)), has been used as a ionophore for the preparation of a new perchlorate ion-selective electrode. The electrode exhibits a Nernstian response over the perchlorate concentration range of 8.0 x 10(-7) -1.0 x 10(-1) M with a slope of 60.3 +/- 0.5 mV per decade of concentration. The limit of detection as determined from the intersection of the extrapolated linear segments of the calibration plot is 5.6 x 10(-7) M. The electrode shows good selectivity towards perchlorate with respect to many common anions. The response time of the sensor is very fast (<= 5 5), and can be used for at least 2 months in the pH range of 2.0-9.0. The electrode was used to determine perchlorate in water and human urine. The interaction of the ionophore with perchlorate ions was demonstrated by UV-vis spectroscopy. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:641 / 648
页数:8
相关论文