EVALUATION OF MEAN GLANDULAR DOSE IN A FULL-FIELD DIGITAL MAMMOGRAPHY UNIT IN TABRIZ, IRAN

被引:13
|
作者
Riabi, Hamed Alizadeh [1 ]
Mehnati, Parinaz [1 ]
Mesbahi, Asghar [1 ]
机构
[1] Tabriz Univ Med Sci, Dept Med Phys, Fac Med, Tabriz, Iran
关键词
MONTE-CARLO;
D O I
10.1093/rpd/ncq218
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study was aimed at evaluating the mean glandular dose (MGD) and affecting factors during mammography examinations by a full-field digital mammography unit. An extensive quality control program was performed to assure that the unit is properly working. Required information including compressed breast thickness (CBT), breast parenchymal pattern and technical factors used for imaging were recorded. An entrance skin exposure measurement was also performed using slabs of poly-methylmethacrylate with 2-8 cm thickness. On the basis of recorded information and measured data, the MGD was estimated for 1145 mammography examinations obtained from 298 patients. Mean CBTs of 4.9 and 5.8 cm and MGDs of 2 and 2.4 mGy were observed for craniocaudal and mediolateral oblique views, respectively. Significant correlation was seen between MGD and CBT, breast parenchymal pattern and applied kVp and mAs.
引用
收藏
页码:222 / 227
页数:6
相关论文
共 50 条
  • [1] Indices for the evaluation of glandular dose heterogeneity in full-field digital mammography
    Shinohara, Sae
    Araki, Fujio
    Maeda, Megumi
    Okamoto, Rumi
    Nakamura, Mai
    Higashida, Yoshiharu
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2020, 40 (04) : 1429 - 1443
  • [2] Comparison of Mean Glandular Dose between Full-Field Digital Mammography and Digital Breast Tomosynthesis
    Teoh, Kar Choon
    Manan, Hanani Abdul
    Norsuddin, Norhashimah Mohd
    Rizuana, Iqbal Hussain
    [J]. HEALTHCARE, 2021, 9 (12)
  • [3] Average glandular dose with full-field digital mammography - Clinical results
    Hermann, KP
    Kehbel, S
    Obenauer, S
    Fischer, U
    Grabbe, E
    [J]. DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2003, : 502 - 504
  • [4] Average glandular dose with amorphous silicon full-field digital mammography - Clinical results
    Hermann, KP
    Obenauer, S
    Marten, K
    Kehbel, S
    Fischer, U
    Grabbe, E
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (06): : 696 - 699
  • [5] Clinical image quality assessment and mean glandular dose for full field digital mammography
    Nassar, Joyce
    Rizk, Chadia
    Fares, Georges
    Tohme, Carla
    Braidy, Chady
    Farah, Jad
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2024, 44 (01)
  • [6] Evaluation of the exposure dose reduction in full-field digital mammography system
    Tanigoshi, M
    Kobayashi, H
    Uchiyama, N
    Suzuki, T
    Kumazaki, T
    [J]. DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2003, : 149 - 151
  • [7] Evaluation of the potential in radiation dose reduction for full-field digital mammography
    Kasch, Kay-Uwe
    Moftah, Belal A.
    [J]. POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2008, 14 (02) : 87 - 98
  • [8] In vivo average glandular dose evaluation: one-to-one comparison between digital breast tomosynthesis and full-field digital mammography
    Cavagnetto, Francesca
    Taccini, Gianni
    Rosasco, Raffaella
    Bampi, Rossana
    Calabrese, Massimo
    Tagliafico, Alberto
    [J]. RADIATION PROTECTION DOSIMETRY, 2013, 157 (01) : 53 - 61
  • [9] Full-field digital mammography
    Bick, U
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (12): : 957 - 964
  • [10] Full-field digital mammography
    U Bick
    [J]. Breast Cancer Research, 2 (Suppl 2)