In vivo average glandular dose evaluation: one-to-one comparison between digital breast tomosynthesis and full-field digital mammography

被引:15
|
作者
Cavagnetto, Francesca [1 ]
Taccini, Gianni [1 ]
Rosasco, Raffaella [2 ]
Bampi, Rossana [1 ]
Calabrese, Massimo [1 ]
Tagliafico, Alberto [3 ]
机构
[1] AOU IRCCS San Martino IST, SC Fis Med & Sanit, Dept Med Phys & Radiol, I-16132 Genoa, Italy
[2] Univ Genoa, DIST, I-16132 Genoa, Italy
[3] Univ Genoa, DIMES, I-16132 Genoa, Italy
关键词
SYSTEM;
D O I
10.1093/rpd/nct120
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
We analysed 300 patients X rayed with digital breast tomosynthesis (DBT), full-field digital mammography (FFDM) and COMBO (single view both in FFDM and DBT in a single breast compression)uHologic Selenia DimensionuW/RhAgAl: three different anode-filter combinationsuautomatic exposure control modalities. Examination parameter data collection (EPDC) and in vivo dosimetry using metal oxide semiconductor field effect transistor (MOSFET) were utilised to determine and compare entrance skin air kerma (ESAK) and average glandular dose (AGD) from a radioprotection viewpoint in the DBT and COMBO modalities. MOSFET has been tested to be introduced in clinical routine. EPDC of DBT underlines increase in ESAK and AGD compared with FFDM (p 0.05). The mean percentage increase was 34 (17 ) in ESAK and 46 (16 ) in AGD. In the COMBO modality, the mean percentage increase in ESAK was 162 (41 ) and in AGD was 202 (61 ). Differences between MOSFET measurement and calculated values were 8 for breasts thicker than 30 mm; otherwise, the errors are 15 . DBT increases ESAK and AGD, due to the 3D acquisition modality. MOSFET may be considered in DBT as a routine check.
引用
收藏
页码:53 / 61
页数:9
相关论文
共 50 条
  • [1] Comparison of Mean Glandular Dose between Full-Field Digital Mammography and Digital Breast Tomosynthesis
    Teoh, Kar Choon
    Manan, Hanani Abdul
    Norsuddin, Norhashimah Mohd
    Rizuana, Iqbal Hussain
    [J]. HEALTHCARE, 2021, 9 (12)
  • [2] Average Glandular Dose in Digital Mammography and Breast Tomosynthesis
    Olgar, T.
    Kahn, T.
    Gosch, D.
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2012, 184 (10): : 911 - 918
  • [3] A comparison between digital breast tomosynthesis and full-field digital mammography for the detection of breast cancers
    Woo Jung Choi
    Hak Hee Kim
    Sun Young Lee
    Eun Young Chae
    Hee Jung Shin
    Joo Hee Cha
    Byung Ho Son
    Sei Hyun Ahn
    Young-Wook Choi
    [J]. Breast Cancer, 2016, 23 : 886 - 892
  • [4] A comparison between digital breast tomosynthesis and full-field digital mammography for the detection of breast cancers
    Choi, Woo Jung
    Kim, Hak Hee
    Lee, Sun Young
    Chae, Eun Young
    Shin, Hee Jung
    Cha, Joo Hee
    Son, Byung Ho
    Ahn, Sei Hyun
    Choi, Young-Wook
    [J]. BREAST CANCER, 2016, 23 (06) : 886 - 892
  • [5] Average glandular dose with full-field digital mammography - Clinical results
    Hermann, KP
    Kehbel, S
    Obenauer, S
    Fischer, U
    Grabbe, E
    [J]. DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2003, : 502 - 504
  • [6] A comparison of reading times in full-field digital mammography and digital breast tomosynthesis
    Connor, S. J.
    Lim, Y. Y.
    Tate, C.
    Entwistle, H.
    Morris, J.
    Whiteside, S.
    Sergeant, J.
    Wilson, M.
    Beetles, U.
    Boggis, C.
    Gilbert, F.
    Astley, S.
    [J]. BREAST CANCER RESEARCH, 2012, 14
  • [7] A comparison of reading times in full-field digital mammography and digital breast tomosynthesis
    SJ Connor
    YY Lim
    C Tate
    H Entwistle
    J Morris
    S Whiteside
    J Sergeant
    M Wilson
    U Beetles
    C Boggis
    F Gilbert
    S Astley
    [J]. Breast Cancer Research, 14
  • [8] Assessment of extent of breast cancer: Comparison between digital breast tomosynthesis and full-field digital mammography
    Mun, H. S.
    Kim, H. H.
    Shin, H. J.
    Cha, J. H.
    Ruppel, P. L.
    Oh, H. Y.
    Chae, E. Y.
    [J]. CLINICAL RADIOLOGY, 2013, 68 (12) : 1254 - 1259
  • [9] DIGITAL BREAST TOMOSYNTHESIS IN ONE OR TWO VIEWS AS A REPLACEMENT OR ADJUNCT TECHNIQUE TO FULL-FIELD DIGITAL MAMMOGRAPHY
    Svahn, T. M.
    Houssami, N.
    [J]. RADIATION PROTECTION DOSIMETRY, 2015, 165 (1-4) : 314 - 320
  • [10] Average glandular dose in digital mammography and digital breast tomosynthesis: comparison of phantom and patient data
    Bouwman, R. W.
    van Engen, R. E.
    Young, K. C.
    den Heeten, G. J.
    Broeders, M. J. M.
    Schopphoven, S.
    Jeukens, C. R. L. P. N.
    Veldkamp, W. J. H.
    Dance, D. R.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (20): : 7893 - 7907