Comparison of Mean Glandular Dose between Full-Field Digital Mammography and Digital Breast Tomosynthesis

被引:20
|
作者
Teoh, Kar Choon [1 ]
Manan, Hanani Abdul [2 ]
Norsuddin, Norhashimah Mohd [3 ]
Rizuana, Iqbal Hussain [1 ]
机构
[1] Univ Kebangsaan Malaysia, Dept Radiol, Med Ctr, Jalan Yaacob Latif, Bandar Tun Razak 56000, Cheras, Malaysia
[2] Univ Kebangsaan Malaysia, Funct Image Proc Lab, Dept Radiol, Med Ctr, Jalan Yaacob Latif, Bandar Tun Razak 56000, Cheras, Malaysia
[3] Univ Kebangsaan Malaysia, Diagnost Imaging & Radiotherapy Program, Kuala Lumpur 50586, Malaysia
关键词
mean glandular dose; mammography; breast cancer and digital breast tomography; SCREEN-FILM;
D O I
10.3390/healthcare9121758
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Early detection of breast cancer is diagnosed using mammography, the gold standard in breast screening. However, its increased use also provokes radiation-induced breast malignancy. Thus, monitoring and regulating the mean glandular dose (MGD) is essential. The purpose of this study was to determine MGD for full-field digital mammography (FFDM) and digital breast tomosynthesis (DBT) in the radiology department of a single centre. We also analysed the exposure factors as a function of breast thickness. A total of 436 patients underwent both FFDM and DBT. MGD was auto calculated by the mammographic machine for each projection. Patients' data included compressed breast thickness (CBT), peak kilovoltage (kVp), milliampere-seconds (mAs) and MGD (mGy). Result analysis showed that there is a significant difference in MGD between the two systems, namely FFDM and DBT. However, the MGD values in our centre were comparable to other centres, as well as the European guideline (<2.5 mGy) for a standard breast. Although DBT improves the clinical outcome and quality of diagnosis, the risk of radiation-induced carcinogenesis should not be neglected. Regular quality control testing on mammography equipment must be performed for dose monitoring in women following a screening mammography in the future.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] In vivo average glandular dose evaluation: one-to-one comparison between digital breast tomosynthesis and full-field digital mammography
    Cavagnetto, Francesca
    Taccini, Gianni
    Rosasco, Raffaella
    Bampi, Rossana
    Calabrese, Massimo
    Tagliafico, Alberto
    [J]. RADIATION PROTECTION DOSIMETRY, 2013, 157 (01) : 53 - 61
  • [2] A comparison between digital breast tomosynthesis and full-field digital mammography for the detection of breast cancers
    Woo Jung Choi
    Hak Hee Kim
    Sun Young Lee
    Eun Young Chae
    Hee Jung Shin
    Joo Hee Cha
    Byung Ho Son
    Sei Hyun Ahn
    Young-Wook Choi
    [J]. Breast Cancer, 2016, 23 : 886 - 892
  • [3] A comparison between digital breast tomosynthesis and full-field digital mammography for the detection of breast cancers
    Choi, Woo Jung
    Kim, Hak Hee
    Lee, Sun Young
    Chae, Eun Young
    Shin, Hee Jung
    Cha, Joo Hee
    Son, Byung Ho
    Ahn, Sei Hyun
    Choi, Young-Wook
    [J]. BREAST CANCER, 2016, 23 (06) : 886 - 892
  • [4] A comparison of reading times in full-field digital mammography and digital breast tomosynthesis
    Connor, S. J.
    Lim, Y. Y.
    Tate, C.
    Entwistle, H.
    Morris, J.
    Whiteside, S.
    Sergeant, J.
    Wilson, M.
    Beetles, U.
    Boggis, C.
    Gilbert, F.
    Astley, S.
    [J]. BREAST CANCER RESEARCH, 2012, 14
  • [5] A comparison of reading times in full-field digital mammography and digital breast tomosynthesis
    SJ Connor
    YY Lim
    C Tate
    H Entwistle
    J Morris
    S Whiteside
    J Sergeant
    M Wilson
    U Beetles
    C Boggis
    F Gilbert
    S Astley
    [J]. Breast Cancer Research, 14
  • [6] Assessment of extent of breast cancer: Comparison between digital breast tomosynthesis and full-field digital mammography
    Mun, H. S.
    Kim, H. H.
    Shin, H. J.
    Cha, J. H.
    Ruppel, P. L.
    Oh, H. Y.
    Chae, E. Y.
    [J]. CLINICAL RADIOLOGY, 2013, 68 (12) : 1254 - 1259
  • [7] Comparison of screening full-field digital mammography and digital breast tomosynthesis technical recalls
    Salkowski, Lonie R.
    Elezaby, Mai
    Fowler, Amy M.
    Burnside, Elizabeth
    Woods, Ryan W.
    Strigel, Roberta M.
    [J]. JOURNAL OF MEDICAL IMAGING, 2019, 6 (03)
  • [8] Comparison of screening full-field digital mammography and digital breast tomosynthesis technical recalls
    Salkowski, Lonie R.
    Elezaby, Mai
    Fowler, Amy M.
    Burnside, Elizabeth
    Woods, Ryan W.
    Strigel, Roberta M.
    [J]. 14TH INTERNATIONAL WORKSHOP ON BREAST IMAGING (IWBI 2018), 2018, 10718
  • [9] A comparison of the accuracy of film-screen mammography, full-field digital mammography, and digital breast tomosynthesis
    Michell, M. J.
    Iqbal, A.
    Wasan, R. K.
    Evans, D. R.
    Peacock, C.
    Lawinski, C. P.
    Douiri, A.
    Wilson, R.
    Whelehan, P.
    [J]. CLINICAL RADIOLOGY, 2012, 67 (10) : 976 - 981
  • [10] Comparison of full-field digital mammography and digital breast tomosynthesis in ultrasonography-detected breast cancers
    Nam, Kyung Jin
    Han, Boo-Kyung
    Ko, Eun Sook
    Choi, Ji Soo
    Ko, Eun Young
    Jeong, Dong Wook
    Choo, Ki Seok