Full-field digital mammography

被引:28
|
作者
Bick, U
机构
[1] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
[2] Free Univ Berlin, Klinikum Charite, Inst Radiol, Berlin, Germany
关键词
digital mammography; breast cancer; screening; PACS; computer-assisted diagnosis;
D O I
10.1055/s-2000-9210
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Due to the extremely high image quality requirements in mammography, there has for a long time been no adequate digital alternative to conventional film-screen mammography. The longest experience so far exists with digital mammography on the basis of storage phosphor (CR) systems. However, at normal dose this technique has a relatively poor signal-to-noise ratio and has not found general acceptance. Recently three novel systems for digital mammography by the companies Fischer (slot-scan detector), Trex (CCD-array), and GE (amorphous silicon detector) have been introduced and are currently under clinical investigation. The main advantage of digital mammography is the linear relationship between dose and detector signal with the possibility of a tailored optimization of image contrast. Other advantages include digital image storage, telemammography, and computer-assisted diagnosis.
引用
收藏
页码:957 / 964
页数:8
相关论文
共 50 条
  • [1] Full-field digital mammography
    U Bick
    Breast Cancer Research, 2 (Suppl 2)
  • [2] Digital Mammography Versus Full-Field Digital Mammography
    Hall, Ferris M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (01) : 240 - 240
  • [3] Comparison of full-field digital mammography with CR mammography
    Uchiyama, N
    Kobayashi, H
    Tajima, H
    Machida, M
    Kumazaki, T
    Moriyama, N
    RADIOLOGY, 2002, 225 : 119 - 119
  • [4] Comparison of Radiologist Performance with Photon-Counting Full-Field Digital Mammography to Conventional Full-Field Digital Mammography
    Cole, Elodia B.
    Toledano, Alicia Y.
    Lundqvist, Mats
    Pisano, Etta D.
    ACADEMIC RADIOLOGY, 2012, 19 (08) : 916 - 922
  • [5] Advantages of gridless full-field digital mammography
    Nykanen, KM
    Siltanen, S
    RADIOLOGY, 2002, 225 : 120 - 121
  • [6] Mammographic Artifacts on Full-Field Digital Mammography
    Choi, Jae Jeong
    Kim, Sung Hun
    Kang, Bong Joo
    Choi, Byung Gil
    Song, ByungJoo
    Jung, Haijo
    JOURNAL OF DIGITAL IMAGING, 2014, 27 (02) : 231 - 236
  • [7] Current status of full-field digital mammography
    Pisano, ED
    RADIOLOGY, 2000, 214 (01) : 26 - 28
  • [8] Mammographic Artifacts on Full-Field Digital Mammography
    Jae Jeong Choi
    Sung Hun Kim
    Bong Joo Kang
    Byung Gil Choi
    ByungJoo Song
    Haijo Jung
    Journal of Digital Imaging, 2014, 27 : 231 - 236
  • [9] Advantages of gridless full-field digital mammography
    Nykänen, K
    Siltanen, S
    MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 137 - 146
  • [10] Current status of full-field digital mammography
    Pisano, ED
    Yaffe, MJ
    Hemminger, BM
    Hendrick, RE
    Niklason, LT
    Maidment, ADA
    Kimme-Smith, CM
    Feig, SA
    Sickles, EA
    Braeuning, MP
    ACADEMIC RADIOLOGY, 2000, 7 (04) : 266 - 280