Advantages of gridless full-field digital mammography

被引:0
|
作者
Nykänen, K [1 ]
Siltanen, S [1 ]
机构
[1] Instrumentarium Corp, Imaging Div, FIN-04301 Tuusula, Finland
关键词
amorphous selenium; X-ray scattering; scatter fraction; scatter-to-primary ratio; full-field digital mammography; point spread function; edge spread function; grid; convolution;
D O I
10.1117/12.479944
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of the study was to find out whether the image quality in full-field digital mammography can be improved while lowering the patient dose by removing the anti-scatter grid. Moreover, a fast approximate computational algorithm was developed for determining the scattered field in a real mammogram. The method is non-iterative, robust against noise, and works without modification for any scatter-to-primary ratio. Furthermore, it is computationally effective since it is based on fast Fourier transform (FFT). It was found out that the wide dynamic range of digital detectors leads to decrease in patient dose from 10.9% up to 46.6.% at breast thickness of 2cm and from 0.8% up to 40.8% at breast thickness of 4cm depending on the efficiency of the removed grid. At constant patient dose the increase in contrast-to-noise ratio is 5.8% - 36.9% and 0.4%-30.0% accordingly at those two breast thickness. The convolution-based X-ray scatter model was considered. The developed scatter removal method was demonstrated with simulated mammograms and applied to clinical full-field digital mammograms acquired with a high-end digital flat panel detector based on amorphous selenium. Errors in reconstructed scattered fields were 0.3% in case of an ideal simulated mammogram and 7.4% in case of a real simulated mammogram (3cm breast). Applications where the scattered field needs to be determined include 3-D mammography and dual-energy breast imaging. In screening mammography gray-scale optimization eliminates the effect of scattering.
引用
收藏
页码:137 / 146
页数:10
相关论文
共 50 条
  • [1] Advantages of gridless full-field digital mammography
    Nykanen, KM
    Siltanen, S
    [J]. RADIOLOGY, 2002, 225 : 120 - 121
  • [2] Dose reduction through gridless technique in digital full-field mammography
    Diekmann, F
    Diekmann, S
    Berzeg, S
    Bick, U
    Fischer, T
    Hamm, B
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2003, 175 (06): : 769 - 774
  • [3] Full-field digital mammography
    Bick, U
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (12): : 957 - 964
  • [4] Full-field digital mammography
    U Bick
    [J]. Breast Cancer Research, 2 (Suppl 2)
  • [5] Digital Mammography Versus Full-Field Digital Mammography
    Hall, Ferris M.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (01) : 240 - 240
  • [6] Comparison of full-field digital mammography with CR mammography
    Uchiyama, N
    Kobayashi, H
    Tajima, H
    Machida, M
    Kumazaki, T
    Moriyama, N
    [J]. RADIOLOGY, 2002, 225 : 119 - 119
  • [7] Comparison of Radiologist Performance with Photon-Counting Full-Field Digital Mammography to Conventional Full-Field Digital Mammography
    Cole, Elodia B.
    Toledano, Alicia Y.
    Lundqvist, Mats
    Pisano, Etta D.
    [J]. ACADEMIC RADIOLOGY, 2012, 19 (08) : 916 - 922
  • [8] Mammographic Artifacts on Full-Field Digital Mammography
    Choi, Jae Jeong
    Kim, Sung Hun
    Kang, Bong Joo
    Choi, Byung Gil
    Song, ByungJoo
    Jung, Haijo
    [J]. JOURNAL OF DIGITAL IMAGING, 2014, 27 (02) : 231 - 236
  • [9] Current status of full-field digital mammography
    Pisano, ED
    [J]. RADIOLOGY, 2000, 214 (01) : 26 - 28
  • [10] Mammographic Artifacts on Full-Field Digital Mammography
    Jae Jeong Choi
    Sung Hun Kim
    Bong Joo Kang
    Byung Gil Choi
    ByungJoo Song
    Haijo Jung
    [J]. Journal of Digital Imaging, 2014, 27 : 231 - 236