Full-field digital mammography

被引:28
|
作者
Bick, U
机构
[1] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
[2] Free Univ Berlin, Klinikum Charite, Inst Radiol, Berlin, Germany
关键词
digital mammography; breast cancer; screening; PACS; computer-assisted diagnosis;
D O I
10.1055/s-2000-9210
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Due to the extremely high image quality requirements in mammography, there has for a long time been no adequate digital alternative to conventional film-screen mammography. The longest experience so far exists with digital mammography on the basis of storage phosphor (CR) systems. However, at normal dose this technique has a relatively poor signal-to-noise ratio and has not found general acceptance. Recently three novel systems for digital mammography by the companies Fischer (slot-scan detector), Trex (CCD-array), and GE (amorphous silicon detector) have been introduced and are currently under clinical investigation. The main advantage of digital mammography is the linear relationship between dose and detector signal with the possibility of a tailored optimization of image contrast. Other advantages include digital image storage, telemammography, and computer-assisted diagnosis.
引用
收藏
页码:957 / 964
页数:8
相关论文
共 50 条
  • [21] CCD-based detector for full-field digital mammography
    Stanton, M
    Phillips, W
    Stewart, A
    Smilowitz, L
    Williams, MB
    Simoni, P
    Ingersoll, C
    McCauley, T
    Qian, H
    MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 : 740 - 748
  • [22] Digital luminescence mammography (CR) versus full-field digital mammography (DR): A phantom study
    Schulz-Wendtland, RW
    Aichinger, UG
    Lell, MM
    Kuchar, I
    Tartsch, M
    Bautz, WA
    RADIOLOGY, 2002, 225 : 416 - 417
  • [23] Baseline Screening Mammography: Performance of Full-Field Digital Mammography Versus Digital Breast Tomosynthesis
    McDonald, Elizabeth S.
    McCarthy, Anne Marie
    Akhtar, Amana L.
    Synnestvedt, Marie B.
    Schnall, Mitchell
    Conant, Emily F.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (05) : 1143 - 1148
  • [24] Enhancement of microcalcifications in full-field digital mammography by energy subtraction
    Diekmann, F
    Diekmann, S
    Bick, U
    Hamm, B
    DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2003, : 577 - 580
  • [25] Full-field digital mammography on LCD versus CRT monitors
    Zuley, Margarita L.
    Willison, Kathleen M.
    Bonaccio, Ermelinda
    Miller, David P.
    Leong, David L.
    Seifert, Posy J.
    Somerville, Patricia
    Destounis, Stamatia
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 187 (06) : 1492 - 1498
  • [26] Diagnostic value of full-field digital mammography for breast tumors
    Ji, T.
    Huang, T.
    Wang, Y.
    Zhu, G.
    Zhou, B.
    Shao, Q.
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2019, 125 : 42 - 42
  • [27] Development of a quality control system for full-field digital mammography
    Yaffe, MJ
    Williams, MB
    Niklason, LT
    Mawdsley, GE
    Maidment, AD
    RADIOLOGY, 1998, 209P : 160 - 160
  • [28] Full-field digital mammography - System development and technical performance
    Yaffe, MJ
    Plewes, DB
    Mawdsley, GE
    Critten, J
    Feig, SA
    Maidment, ADA
    Picarro, M
    Tesic, M
    DIGITAL MAMMOGRAPHY '96, 1996, 1119 : 125 - 131
  • [29] X-ray scattering in full-field digital mammography
    Nykänen, K
    Siltanen, S
    MEDICAL PHYSICS, 2003, 30 (07) : 1864 - 1873
  • [30] Clinical evaluation of full-field digital mammography in a screening population
    Lewin, JM
    Hendrick, RE
    D'Orsi, CJ
    Moss, LJ
    Isaacs, P
    RADIOLOGY, 2000, 217 : 199 - 199