Assessment of fetal scalp oxygen saturation determination in the sheep by transmission pulse oximetry

被引:10
|
作者
Nijland, MJM
Shankar, U
Iyer, V
Ross, MG
机构
[1] Cornell Univ, Coll Vet Med, Dept Biomed Sci, Lab Pregnancy & Newborn Res, Ithaca, NY 14853 USA
[2] Respiron Inc, Marietta, GA USA
[3] Univ Calif Los Angeles, Sch Med, Dept Obstet & Gynecol, Perinatal Res Labs, Los Angeles, CA 90024 USA
关键词
fetal scalp transmission pulse oximetry; oxygen saturation; sheep;
D O I
10.1067/mob.2000.107736
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
OBJECTIVE: Electronic fetal heart rate monitoring has an unacceptable false-positive nonreassuring rate, which results in an excess of operative interventions. As a more objective measure of fetal oxygenation, fetal ;scalp pulse oximetry has been used to assess fetal blood oxygen saturation (SO2). The current devices use reflectance oximetry, which has inherent limitations. These include varying depths of signal penetration, variation with position, and potential for optical interference. In this study we evaluated a newly developed transmission pulse oximetry device consisting of transmitter and receiver diodes mounted within the coil of a standard scalp electrode (Spiral O(2)CTG; Respironics Inc, Marietta, Ga). STUDY DESIGN: Six pregnant ewes at 127 to 135 days' gestation (term, 145 days' gestation) were anesthetized, intubated, and prepared with a femoral artery catheter. Fetuses were prepared with brachial artery and jugular vein catheters. Maternal inspired oxygen fraction was titrated from 21% to 3%. Oximetry O(2)CTG devices were positioned on the fetal scalp, and recordings were compared with directly determined fetal arterial pH, Pop, and So, values. RESULTS: Maternal Sao(2) and Pao(2) ranged from 102% to 16% and 110 to 18 mm Hg, respectively. Fetal Sao(2) and Pao(2) ranged from 76% to 12% and 28 to 8 mm Hg, respectively. There was excellent correlation between direct fetal Sao(2) and scalp So(2) (r(2) = 0.90; scalp So(2) = 0.79 Sao(2) + 6.89). With an Sao(2) of <30% as the cutoff point for assessment of fetal compromise, scalp So, measurements had a 94% +/- 10% specificity and a 94% +/- 10% positive predictive value. CONCLUSION: (1) Preliminary studies of the Spiral O(2)CTG sensor demonstrated high correlation of scalp So(2) with fetal Sao(2). (2) Although potential inaccuracies remain, transmission oximetry may offer potential advantages in consistency, ease of application, and technology with respect to the current reflection oximeter devices.
引用
收藏
页码:1549 / 1553
页数:5
相关论文
共 50 条
  • [1] FETAL OXYGEN-SATURATION MEASUREMENT BY TRANSMISSION PULSE OXIMETRY
    BUSCHMANN, J
    RALL, G
    KNITZA, R
    LANCET, 1992, 339 (8793): : 615 - 615
  • [2] CONTINUOUS MONITORING OF FETAL OXYGEN-SATURATION BY PULSE OXIMETRY
    LUTTKUS, A
    FENGLER, TW
    FRIEDMANN, W
    DUDENHAUSEN, JW
    OBSTETRICS AND GYNECOLOGY, 1995, 85 (02): : 183 - 186
  • [3] Fetal transmission pulse oximetry
    Masin, DI
    Paulsen, AW
    Brouillard, RG
    Iyer, VK
    PROCEEDINGS OF THE 19TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 19, PTS 1-6: MAGNIFICENT MILESTONES AND EMERGING OPPORTUNITIES IN MEDICAL ENGINEERING, 1997, 19 : 2326 - 2329
  • [4] The fetal oxygen saturation in premature labor measured by means of intrapartum fetal pulse oximetry
    Roztocil, A
    Kucera, M
    Kachlík, P
    Ventruba, P
    WOMAN AND CHILD BEFORE, DURING AND AFTER PREGNANCY, 2001, : 349 - 354
  • [5] COMPARING FETAL PULSE OXIMETRY WITH SCALP PH
    JOHNSON, N
    MCNAMARA, H
    MONTAGUE, I
    AUMEERALLY, Z
    LILFORD, RJ
    JOURNAL OF REPRODUCTIVE MEDICINE, 1995, 40 (10) : 717 - 720
  • [6] CLINICAL-RESULTS OF FETAL PULSE OXIMETRY MEASURING THE FETAL ARTERIAL OXYGEN-SATURATION
    BUTTERWEGGE, M
    LAMPE, S
    GEBURTSHILFE UND FRAUENHEILKUNDE, 1995, 55 (11) : 634 - 641
  • [7] INTRAPARTUM FETAL PULSE OXIMETRY - THE EFFECTS OF MATERNAL HYPEROXIA ON FETAL ARTERIAL OXYGEN-SATURATION
    DILDY, GA
    CLARK, SL
    LOUCKS, CA
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1994, 171 (04) : 1120 - 1124
  • [8] The reliability of fetal pulse oximetry: The effect of fetal oxygen saturation below 30% on perinatal outcome
    Csitari, Istvan Kis
    Pasztuhov, Agoston
    Laszlo, Adam
    EUROPEAN JOURNAL OF OBSTETRICS GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2008, 136 (02): : 160 - 164
  • [9] Fetal transmission pulse oximetry: Is it accurate?
    Nijland, R
    van den Berg, PP
    Jongsma, HW
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2001, 185 (03) : 776 - 776
  • [10] Effects of maternal oxygen administration on fetal pulse oximetry measured by fetal pulse oximetry
    Haydon, Michael L.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2007, 196 (04)