Assessment of fetal scalp oxygen saturation determination in the sheep by transmission pulse oximetry

被引:10
|
作者
Nijland, MJM
Shankar, U
Iyer, V
Ross, MG
机构
[1] Cornell Univ, Coll Vet Med, Dept Biomed Sci, Lab Pregnancy & Newborn Res, Ithaca, NY 14853 USA
[2] Respiron Inc, Marietta, GA USA
[3] Univ Calif Los Angeles, Sch Med, Dept Obstet & Gynecol, Perinatal Res Labs, Los Angeles, CA 90024 USA
关键词
fetal scalp transmission pulse oximetry; oxygen saturation; sheep;
D O I
10.1067/mob.2000.107736
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
OBJECTIVE: Electronic fetal heart rate monitoring has an unacceptable false-positive nonreassuring rate, which results in an excess of operative interventions. As a more objective measure of fetal oxygenation, fetal ;scalp pulse oximetry has been used to assess fetal blood oxygen saturation (SO2). The current devices use reflectance oximetry, which has inherent limitations. These include varying depths of signal penetration, variation with position, and potential for optical interference. In this study we evaluated a newly developed transmission pulse oximetry device consisting of transmitter and receiver diodes mounted within the coil of a standard scalp electrode (Spiral O(2)CTG; Respironics Inc, Marietta, Ga). STUDY DESIGN: Six pregnant ewes at 127 to 135 days' gestation (term, 145 days' gestation) were anesthetized, intubated, and prepared with a femoral artery catheter. Fetuses were prepared with brachial artery and jugular vein catheters. Maternal inspired oxygen fraction was titrated from 21% to 3%. Oximetry O(2)CTG devices were positioned on the fetal scalp, and recordings were compared with directly determined fetal arterial pH, Pop, and So, values. RESULTS: Maternal Sao(2) and Pao(2) ranged from 102% to 16% and 110 to 18 mm Hg, respectively. Fetal Sao(2) and Pao(2) ranged from 76% to 12% and 28 to 8 mm Hg, respectively. There was excellent correlation between direct fetal Sao(2) and scalp So(2) (r(2) = 0.90; scalp So(2) = 0.79 Sao(2) + 6.89). With an Sao(2) of <30% as the cutoff point for assessment of fetal compromise, scalp So, measurements had a 94% +/- 10% specificity and a 94% +/- 10% positive predictive value. CONCLUSION: (1) Preliminary studies of the Spiral O(2)CTG sensor demonstrated high correlation of scalp So(2) with fetal Sao(2). (2) Although potential inaccuracies remain, transmission oximetry may offer potential advantages in consistency, ease of application, and technology with respect to the current reflection oximeter devices.
引用
收藏
页码:1549 / 1553
页数:5
相关论文
共 50 条
  • [31] FETAL OXYGEN-SATURATION IN CASES WITH SUSPECTED HYPOXIA AND NORMAL CARDIOTOCOGRAM - A PROSPECTIVE INVESTIGATION ABOUT FETAL PULSE OXIMETRY
    LUTTKUS, A
    FENGLER, TW
    FRIEDMANN, W
    NIMPSCH, R
    DUDENHAUSEN, JW
    ZEITSCHRIFT FUR GEBURTSHILFE UND PERINATOLOGIE, 1994, 198 (02): : 62 - 66
  • [32] Transmission pulse oximetry in the fetal lamb: Is there a universal calibration?
    Nijland, R
    Jongsma, HW
    Crevels, J
    Menssen, JJM
    Nijhuis, JG
    Oeseburg, B
    PEDIATRIC RESEARCH, 1996, 39 (03) : 464 - 469
  • [33] Fetal pulse oximetry during labor: oxygen saturation values in fetuses with and without umbilical cord complications
    De Morais, EN
    Gallarreta, FMP
    Spara, P
    Gressler, JT
    4TH WORLD CONGRESS OF PERINATAL MEDICINE, 1999, : 135 - 138
  • [34] PREDICTING CHANGES IN OXYGEN-SATURATION USING PULSE OXIMETRY
    SAPSFORD, DJ
    JONES, JG
    BRITISH JOURNAL OF ANAESTHESIA, 1988, 61 (04) : P497 - P497
  • [35] Blood haemoglobin and pulse oximetry oxygen saturation measurement error
    Crooks, C.
    West, J.
    Morling, J.
    Simmonds, M.
    Juurlink, I.
    Briggs, S.
    Cruickshank, S.
    Hammond-Pears, S.
    Shaw, D.
    Card, T.
    Fogarty, A.
    EUROPEAN RESPIRATORY JOURNAL, 2022, 60
  • [36] TIME TO EQUILIBRATION OF OXYGEN-SATURATION USING PULSE OXIMETRY
    GRUBER, P
    KWIATKOWSKI, T
    SILVERMAN, R
    FLASTER, E
    AUERBACH, C
    ACADEMIC EMERGENCY MEDICINE, 1995, 2 (09) : 810 - 815
  • [37] BIOLOGICAL QUALITY CONTROL FOR PULSE OXIMETRY OXYGEN SATURATION MEASUREMENT
    Back, Geraldine M.
    Dooney, Natalie A.
    Robiony-Rogers, David
    RESPIROLOGY, 2012, 17 : 7 - 7
  • [38] MONITORING OF ARTERIAL OXYGEN-SATURATION BY PULSE OXIMETRY - COMMENT
    SALEM, CJ
    JANDA, A
    BERGER, M
    BRANDSTETTER, A
    ANASTHESIOLOGIE & INTENSIVMEDIZIN, 1988, 29 (10): : 293 - 293
  • [39] Fetal oxygen saturation measured by pulse oximetry during labour with clear or meconium-stained amniotic fluid
    Carbonne, B
    Cudeville, C
    Sivan, H
    Cabrol, D
    Papiernik, E
    EUROPEAN JOURNAL OF OBSTETRICS GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 1997, 72 : S51 - S55
  • [40] Assessment of hemoglobin saturation by pulse oximetry in healthy newborn calves
    Uystepruyst, C
    Coghe, J
    Bureau, F
    Van de Weerdt, ML
    Art, T
    Lekeux, P
    PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1998, 435 (06): : R249 - R249