TIME TO EQUILIBRATION OF OXYGEN-SATURATION USING PULSE OXIMETRY

被引:16
|
作者
GRUBER, P
KWIATKOWSKI, T
SILVERMAN, R
FLASTER, E
AUERBACH, C
机构
[1] ALBERT EINSTEIN COLL MED,DEPT EMERGENCY MED,NEW HYDE PK,NY
[2] ALBERT EINSTEIN COLL MED,DEPT SOCIAL SERV,NEW HYDE PK,NY
[3] WINTHROP UNIV HOSP,MINEOLA,NY 11501
关键词
OXYGEN SATURATION; PULSE OXIMETRY; OXYGEN ADMINISTRATION; EQUILIBRATION;
D O I
10.1111/j.1553-2712.1995.tb03276.x
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To determine the time it takes for O-2 saturation measured by pulse oximetry to equilibrate after a change is made in supplemental O-2 administered by nasal cannula in patients with cardiac and pulmonary disease. Methods: A prospective, observational study of a convenience sample of 51 patients treated in a university-affiliated ED with nasal cannula O-2. Patients were placed on and/or subsequently taken off O-2 via nasal cannula set at 2 or 4 L/min based on clinical indications. Oxygen saturation was measured at 1-minute intervals over a 30-minute period using finger-probe pulse oximetry. Of the 51 patients in the study, 43 were monitored while O-2 treatment was initiated and 18 were monitored when it was discontinued. Results: Most (95%) of the patients placed on O-2 attained equilibration of O-2 saturation within 3.5 minutes. Most (95%) of the patients taken off supplemental O-2 attained equilibration of O-2 saturation within 4.5 minutes. Conclusion: The interval to equilibration of O-2 saturation in patients receiving O-2 by nasal cannula is considerably shorter than the 20-30 minutes generally suggested. Adequacy of O-2 supplementation should be assessable much sooner than was previously taught.
引用
收藏
页码:810 / 815
页数:6
相关论文
共 50 条
  • [1] PREDICTING CHANGES IN OXYGEN-SATURATION USING PULSE OXIMETRY
    SAPSFORD, DJ
    JONES, JG
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1988, 61 (04) : P497 - P497
  • [2] MONITORING OF ARTERIAL OXYGEN-SATURATION BY PULSE OXIMETRY
    STRIEBEL, HW
    STEINHOFF, U
    KRETZ, FJ
    [J]. ANASTHESIOLOGIE & INTENSIVMEDIZIN, 1988, 29 (01): : 8 - 16
  • [3] NASAL PULSE OXIMETRY OVERESTIMATES OXYGEN-SATURATION
    ROSENBERG, J
    PEDERSEN, MH
    [J]. ANAESTHESIA, 1990, 45 (12) : 1070 - 1071
  • [4] EXPLANATION FOR THE OVERESTIMATION OF OXYGEN-SATURATION SEEN USING NASAL PULSE OXIMETRY
    BROOME, IJ
    REILLY, CS
    [J]. ANAESTHESIA, 1991, 46 (05) : 424 - 424
  • [5] VALIDATION OF ARTERIAL OXYGEN-SATURATION MEASUREMENTS INUTERO USING PULSE OXIMETRY
    HARRIS, AP
    SENDAK, MJ
    CHUNG, DC
    RICHARDSON, CA
    [J]. AMERICAN JOURNAL OF PERINATOLOGY, 1993, 10 (03) : 250 - 254
  • [6] FETAL OXYGEN-SATURATION MEASUREMENT BY TRANSMISSION PULSE OXIMETRY
    BUSCHMANN, J
    RALL, G
    KNITZA, R
    [J]. LANCET, 1992, 339 (8793): : 615 - 615
  • [7] CONTINUOUS MONITORING OF FETAL OXYGEN-SATURATION BY PULSE OXIMETRY
    LUTTKUS, A
    FENGLER, TW
    FRIEDMANN, W
    DUDENHAUSEN, JW
    [J]. OBSTETRICS AND GYNECOLOGY, 1995, 85 (02): : 183 - 186
  • [8] MONITORING OF ARTERIAL OXYGEN-SATURATION BY PULSE OXIMETRY - COMMENT
    SALEM, CJ
    JANDA, A
    BERGER, M
    BRANDSTETTER, A
    [J]. ANASTHESIOLOGIE & INTENSIVMEDIZIN, 1988, 29 (10): : 293 - 293
  • [10] PULSE OXIMETRY IN METHEMOGLOBINEMIA - FAILURE TO DETECT LOW OXYGEN-SATURATION
    RIEDER, HU
    FREI, FJ
    ZBINDEN, AM
    THOMSON, DA