CONTINUOUS MONITORING OF FETAL OXYGEN-SATURATION BY PULSE OXIMETRY

被引:48
|
作者
LUTTKUS, A
FENGLER, TW
FRIEDMANN, W
DUDENHAUSEN, JW
机构
[1] Department of Obstetrics, University Hospital Rudolf Virchow, Berlin
来源
OBSTETRICS AND GYNECOLOGY | 1995年 / 85卷 / 02期
关键词
D O I
10.1016/0029-7844(94)00353-F
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: To compare spectrophotometric saturation values of fetal blood sampling to the saturation readings by pulse oximetry. Methods: During a clinical trial, fetal oxygen saturation was monitored during labor by a fetal oxisensor and a fetal pulse oximeter. Fifty-one fetal scalp blood samples were assessed because of abnormal fetal heart rate (FHR) patterns. The pulse oximeter displayed only signal quality readings. The investigator had to perform adjustments if signal quality fell below 50%. After delivery, the saturation at the moment of fetal blood analysis could be read from a printout and compared to the saturation values of scalp blood sampling. Results: The share of usable signal time was 51% overall, but only 40% in the 20-minute period during fetal blood sampling. Comparison with the reference method resulted in a median deviation of 6% (tenth percentile -10%; 90th percentile 18%) for pulse oximetry. The correlation coefficient between saturation values by pulse oximetry and fetal scalp blood sampling was 0.67. The correlation coefficient with the partial pressure of oxygen and oxygen saturation by pulse oximetry was 0.61, whereas it was 0.88 between partial pressure and saturation from the spectrophotometric analysis of the scalp sample. Conclusions: Fetal pulse oximetry corresponds satisfactorily to results from fetal blood analysis. Low invasiveness and continuous monitoring are the advantages of this method. At present, the available sensor generates only a limited amount of signal time. However, in combination with FHR monitoring, pulse oximetry promises greatly improved detection of fetal hypoxia.
引用
收藏
页码:183 / 186
页数:4
相关论文
共 50 条
  • [1] MONITORING OF ARTERIAL OXYGEN-SATURATION BY PULSE OXIMETRY
    STRIEBEL, HW
    STEINHOFF, U
    KRETZ, FJ
    [J]. ANASTHESIOLOGIE & INTENSIVMEDIZIN, 1988, 29 (01): : 8 - 16
  • [2] FETAL OXYGEN-SATURATION MEASUREMENT BY TRANSMISSION PULSE OXIMETRY
    BUSCHMANN, J
    RALL, G
    KNITZA, R
    [J]. LANCET, 1992, 339 (8793): : 615 - 615
  • [3] MONITORING OF ARTERIAL OXYGEN-SATURATION BY PULSE OXIMETRY - COMMENT
    SALEM, CJ
    JANDA, A
    BERGER, M
    BRANDSTETTER, A
    [J]. ANASTHESIOLOGIE & INTENSIVMEDIZIN, 1988, 29 (10): : 293 - 293
  • [4] CONTINUOUS MONITORING OF ARTERIAL OXYGEN-SATURATION WITH PULSE OXIMETRY DURING TRANSFER TO THE RECOVERY ROOM
    TYLER, IL
    TANTISIRA, B
    WINTER, PM
    MOTOYAMA, EK
    [J]. ANESTHESIA AND ANALGESIA, 1985, 64 (11): : 1108 - 1112
  • [5] CONTINUOUS INTRAPARTUM MONITORING OF FETAL OXYGEN-SATURATION
    GARDOSI, J
    CARTER, M
    BECKET, T
    [J]. LANCET, 1989, 2 (8664): : 692 - 693
  • [6] THE CURRENT STATUS OF PULSE OXIMETRY - CLINICAL-VALUE OF CONTINUOUS NONINVASIVE OXYGEN-SATURATION MONITORING
    TAYLOR, MB
    WHITWAM, JG
    [J]. ANAESTHESIA, 1986, 41 (09) : 943 - 949
  • [7] INTRAPARTUM FETAL PULSE OXIMETRY - THE EFFECTS OF MATERNAL HYPEROXIA ON FETAL ARTERIAL OXYGEN-SATURATION
    DILDY, GA
    CLARK, SL
    LOUCKS, CA
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1994, 171 (04) : 1120 - 1124
  • [8] CLINICAL-RESULTS OF FETAL PULSE OXIMETRY MEASURING THE FETAL ARTERIAL OXYGEN-SATURATION
    BUTTERWEGGE, M
    LAMPE, S
    [J]. GEBURTSHILFE UND FRAUENHEILKUNDE, 1995, 55 (11) : 634 - 641
  • [9] EVALUATION OF OXYGEN-SATURATION MONITORING BY PULSE OXIMETRY IN NEONATES IN THE DELIVERY SYSTEM
    DIMICH, I
    SINGH, PP
    ADELL, A
    HENDLER, M
    SONNENKLAR, N
    JHAVERI, M
    [J]. CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1991, 38 (08): : 985 - 988
  • [10] NASAL PULSE OXIMETRY OVERESTIMATES OXYGEN-SATURATION
    ROSENBERG, J
    PEDERSEN, MH
    [J]. ANAESTHESIA, 1990, 45 (12) : 1070 - 1071