CLINICAL-RESULTS OF FETAL PULSE OXIMETRY MEASURING THE FETAL ARTERIAL OXYGEN-SATURATION

被引:6
|
作者
BUTTERWEGGE, M [1 ]
LAMPE, S [1 ]
机构
[1] STADT KLINIKEN OSNABRUCK,FRAUENKLIN,OSNABRUCK,GERMANY
关键词
D O I
10.1055/s-2007-1023538
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
By means of reflexion pulse oximetry the arterial oxygen saturation (SpO(2)) of 100 fetuses intrapartum was measured in a high-risk group and compared with clinical parameters. There is a connection between the duration of SpO(2) measurements below 30%, the delivery mode and reduced pH-values in the umbilical artery measured post partum. SpO(2) values below 30% also occur temporarily with uneventful deliveries but they occur with increased frequency within the group of operatively delivered children with a duration of more than 20 minutes. On the other hand the group with SpO(2) values ranging between 40 and 60% showed less operative deliveries and a better condition of the newborn (Apgar, pH-metry). If prognostically unfavourable additional criteria with variable decelerations increase, a tendency towards decreasing fetal oxygen saturation values is recognisable. In the case of suspicious heart rate patterns or patterns difficult to assess the continuous registration of saturation values is both medically and forensically of inestimable value. There were no increases in fetal morbidity or signs of amnion infection syndrome. By means of a new sensor; a longer registration lime with a reliable signal quality is achieved, so that assessment of the oxygen saturation in relation to labour activity becomes possible.
引用
收藏
页码:634 / 641
页数:8
相关论文
共 50 条
  • [1] INTRAPARTUM FETAL PULSE OXIMETRY - THE EFFECTS OF MATERNAL HYPEROXIA ON FETAL ARTERIAL OXYGEN-SATURATION
    DILDY, GA
    CLARK, SL
    LOUCKS, CA
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1994, 171 (04) : 1120 - 1124
  • [2] FETAL OXYGEN-SATURATION MEASUREMENT BY TRANSMISSION PULSE OXIMETRY
    BUSCHMANN, J
    RALL, G
    KNITZA, R
    LANCET, 1992, 339 (8793): : 615 - 615
  • [3] CONTINUOUS MONITORING OF FETAL OXYGEN-SATURATION BY PULSE OXIMETRY
    LUTTKUS, A
    FENGLER, TW
    FRIEDMANN, W
    DUDENHAUSEN, JW
    OBSTETRICS AND GYNECOLOGY, 1995, 85 (02): : 183 - 186
  • [4] MONITORING OF ARTERIAL OXYGEN-SATURATION BY PULSE OXIMETRY
    STRIEBEL, HW
    STEINHOFF, U
    KRETZ, FJ
    ANASTHESIOLOGIE & INTENSIVMEDIZIN, 1988, 29 (01): : 8 - 16
  • [5] INTRAPARTUM FETAL PULSE OXIMETRY - FETAL OXYGEN-SATURATION TRENDS DURING LABOR AND RELATION TO DELIVERY OUTCOME
    DILDY, GA
    VANDENBERG, PP
    KATZ, M
    CLARK, SL
    JONGSMA, HW
    NIJHUIS, JG
    LOUCKS, CA
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1994, 171 (03) : 679 - 684
  • [6] MONITORING OF ARTERIAL OXYGEN-SATURATION BY PULSE OXIMETRY - COMMENT
    SALEM, CJ
    JANDA, A
    BERGER, M
    BRANDSTETTER, A
    ANASTHESIOLOGIE & INTENSIVMEDIZIN, 1988, 29 (10): : 293 - 293
  • [7] FETAL OXYGEN-SATURATION IN CASES WITH SUSPECTED HYPOXIA AND NORMAL CARDIOTOCOGRAM - A PROSPECTIVE INVESTIGATION ABOUT FETAL PULSE OXIMETRY
    LUTTKUS, A
    FENGLER, TW
    FRIEDMANN, W
    NIMPSCH, R
    DUDENHAUSEN, JW
    ZEITSCHRIFT FUR GEBURTSHILFE UND PERINATOLOGIE, 1994, 198 (02): : 62 - 66
  • [9] THE EFFECT ON FETAL ARTERIOLAR OXYGEN-SATURATION RESULTING FROM GIVING OXYGEN TO THE MOTHER MEASURED BY PULSE OXIMETRY
    MCNAMARA, H
    JOHNSON, N
    LILFORD, R
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1993, 100 (05): : 446 - 449
  • [10] Trans-abdominal monitoring of fetal arterial oxygen saturation using pulse oximetry
    Mawn, T
    Li, PC
    Nioka, S
    Chance, B
    PROCEEDINGS OF THE IEEE 28TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE, 2002, : 227 - 228