CLINICAL-RESULTS OF FETAL PULSE OXIMETRY MEASURING THE FETAL ARTERIAL OXYGEN-SATURATION

被引:6
|
作者
BUTTERWEGGE, M [1 ]
LAMPE, S [1 ]
机构
[1] STADT KLINIKEN OSNABRUCK,FRAUENKLIN,OSNABRUCK,GERMANY
关键词
D O I
10.1055/s-2007-1023538
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
By means of reflexion pulse oximetry the arterial oxygen saturation (SpO(2)) of 100 fetuses intrapartum was measured in a high-risk group and compared with clinical parameters. There is a connection between the duration of SpO(2) measurements below 30%, the delivery mode and reduced pH-values in the umbilical artery measured post partum. SpO(2) values below 30% also occur temporarily with uneventful deliveries but they occur with increased frequency within the group of operatively delivered children with a duration of more than 20 minutes. On the other hand the group with SpO(2) values ranging between 40 and 60% showed less operative deliveries and a better condition of the newborn (Apgar, pH-metry). If prognostically unfavourable additional criteria with variable decelerations increase, a tendency towards decreasing fetal oxygen saturation values is recognisable. In the case of suspicious heart rate patterns or patterns difficult to assess the continuous registration of saturation values is both medically and forensically of inestimable value. There were no increases in fetal morbidity or signs of amnion infection syndrome. By means of a new sensor; a longer registration lime with a reliable signal quality is achieved, so that assessment of the oxygen saturation in relation to labour activity becomes possible.
引用
收藏
页码:634 / 641
页数:8
相关论文
共 50 条
  • [31] A BUCCAL SENSOR FOR MEASURING ARTERIAL OXYGEN-SATURATION
    GUNTER, JB
    ANESTHESIA AND ANALGESIA, 1989, 69 (03): : 417 - 418
  • [32] THE EFFECT OF CARBOXYHEMOGLOBIN ON PULSE-OXIMETRY OXYGEN-SATURATION MEASUREMENTS
    PANACEK, EA
    JOURILLES, NJ
    SHERMAN, BW
    RUTHERFORD, WF
    CLINICAL RESEARCH, 1991, 39 (02): : A421 - A421
  • [33] COMPARISON OF OXYGEN-SATURATION BY PULSE OXIMETER AND ARTERIAL BLOOD-GAS CO-OXIMETRY
    BERLIN, SL
    CRAPO, RO
    JENSEN, RL
    CLINICAL RESEARCH, 1989, 37 (01): : A163 - A163
  • [34] Fetal pulse oximetry: Clinical practice
    Vardon, D.
    Hors, Y.
    Grossetti, E.
    Creveuil, C.
    Herticoviez, M.
    Dreyfus, M.
    JOURNAL DE GYNECOLOGIE OBSTETRIQUE ET BIOLOGIE DE LA REPRODUCTION, 2008, 37 (07): : 697 - 704
  • [35] Fetal pulse oximetry in clinical use
    Kühnert, M
    Seelbach-Göbel, B
    Butterwegge, M
    GEBURTSHILFE UND FRAUENHEILKUNDE, 2001, 61 (05) : 290 - 296
  • [36] FETAL HEPATIC VENOUS OXYGEN-SATURATION AND LIVER OXYGENATION
    RUDOLPH, AM
    BRISTOW, J
    PEDIATRIC RESEARCH, 1981, 15 (04) : 488 - 488
  • [37] A NEW METHOD FOR INTRAPARTUM MEASUREMENT OF FETAL OXYGEN-SATURATION
    KNITZA, R
    RALL, G
    BUSCHMANN, J
    ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 1993, 254 (1-4) : 1515 - 1516
  • [38] Fetal arterial oxygen saturation trends measured by continuous pulse oximetry during labor in subjects with normal delivery outcomes
    De Morais, EN
    Spara, P
    Gressler, JT
    4TH WORLD CONGRESS OF PERINATAL MEDICINE, 1999, : 139 - 142
  • [39] Effect of maternal position on fetal oxygen saturation measured by pulse oximetry during labor
    de Morais, EN
    Spara, P
    El Beitune, P
    Madi, JM
    PERINATOLOGY 2001, VOLS 1 AND 2, 2001, : 283 - 286
  • [40] Maternal position during labor: Effects on fetal oxygen saturation measured by pulse oximetry
    Carbonne, B
    Benachi, A
    Leveque, ML
    Cabrol, D
    Papiernik, E
    OBSTETRICS AND GYNECOLOGY, 1996, 88 (05): : 797 - 800