TIME TO EQUILIBRATION OF OXYGEN-SATURATION USING PULSE OXIMETRY

被引:16
|
作者
GRUBER, P
KWIATKOWSKI, T
SILVERMAN, R
FLASTER, E
AUERBACH, C
机构
[1] ALBERT EINSTEIN COLL MED,DEPT EMERGENCY MED,NEW HYDE PK,NY
[2] ALBERT EINSTEIN COLL MED,DEPT SOCIAL SERV,NEW HYDE PK,NY
[3] WINTHROP UNIV HOSP,MINEOLA,NY 11501
关键词
OXYGEN SATURATION; PULSE OXIMETRY; OXYGEN ADMINISTRATION; EQUILIBRATION;
D O I
10.1111/j.1553-2712.1995.tb03276.x
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To determine the time it takes for O-2 saturation measured by pulse oximetry to equilibrate after a change is made in supplemental O-2 administered by nasal cannula in patients with cardiac and pulmonary disease. Methods: A prospective, observational study of a convenience sample of 51 patients treated in a university-affiliated ED with nasal cannula O-2. Patients were placed on and/or subsequently taken off O-2 via nasal cannula set at 2 or 4 L/min based on clinical indications. Oxygen saturation was measured at 1-minute intervals over a 30-minute period using finger-probe pulse oximetry. Of the 51 patients in the study, 43 were monitored while O-2 treatment was initiated and 18 were monitored when it was discontinued. Results: Most (95%) of the patients placed on O-2 attained equilibration of O-2 saturation within 3.5 minutes. Most (95%) of the patients taken off supplemental O-2 attained equilibration of O-2 saturation within 4.5 minutes. Conclusion: The interval to equilibration of O-2 saturation in patients receiving O-2 by nasal cannula is considerably shorter than the 20-30 minutes generally suggested. Adequacy of O-2 supplementation should be assessable much sooner than was previously taught.
引用
收藏
页码:810 / 815
页数:6
相关论文
共 50 条
  • [21] MONITORING OF ARTERIAL OXYGEN-SATURATION DURING HALOTHANE ANESTHESIA IN THE HORSE USING NASAL-SEPTUM PULSE OXIMETRY
    MOENS, Y
    GOOTJES, P
    LAGERWEIJ, E
    VANDIJK, P
    [J]. BERLINER UND MUNCHENER TIERARZTLICHE WOCHENSCHRIFT, 1991, 104 (10): : 357 - 360
  • [22] EVALUATION OF EAR OXIMETRY IN THE MEASUREMENT OF ARTERIAL OXYGEN-SATURATION
    CABLE, JA
    [J]. JOURNAL OF THE AMERICAN OSTEOPATHIC ASSOCIATION, 1981, 81 (02): : 107 - 112
  • [23] CONTINUOUS INVIVO MEASUREMENT OF ARTERIAL OXYGEN-SATURATION BY OXIMETRY
    FLICK, MR
    BLOCK, AJ
    [J]. HEART & LUNG, 1977, 6 (06): : 990 - 993
  • [24] MEASUREMENT OF RIGHT ATRIAL OXYGEN-SATURATION BY FIBEROPTIC OXIMETRY ACCURATELY REFLECTS MIXED VENOUS OXYGEN-SATURATION IN SWINE
    DAVIES, GG
    MENDENHALL, J
    SYMRENG, T
    [J]. JOURNAL OF CLINICAL MONITORING, 1988, 4 (02): : 99 - 102
  • [25] PULSE OXIMETRY FAILS TO ACCURATELY REFLECT HEMOGLOBIN OXYGEN-SATURATION AT LOW-LEVELS IN DOGS
    SIDI, A
    GRAVENSTEIN, N
    RUSH, W
    PAULUS, DA
    DAVIS, RF
    [J]. CRITICAL CARE MEDICINE, 1987, 15 (04) : 362 - 362
  • [26] SIMULTANEOUS MEASUREMENT OF PREDUCTAL AND POSTDUCTAL OXYGEN-SATURATION BY PULSE OXIMETRY IN HYALINE-MEMBRANE DISEASE
    MACDONALD, PD
    YU, VYH
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 1992, 67 (10): : 1166 - 1168
  • [27] EFFECT OF FLUORESCEIN, INDOCYANINE GREEN, AND METHYLENE-BLUE ON THE MEASUREMENT OF OXYGEN-SATURATION BY PULSE OXIMETRY
    SIDI, A
    RUSH, WR
    PAULUS, DA
    GRAVENSTEIN, N
    DAVIS, RF
    [J]. ANESTHESIOLOGY, 1986, 65 (3A) : A132 - A132
  • [28] COMPARISON OF OXYGEN-SATURATION BY PULSE OXIMETER AND ARTERIAL BLOOD-GAS CO-OXIMETRY
    BERLIN, SL
    CRAPO, RO
    JENSEN, RL
    [J]. CLINICAL RESEARCH, 1989, 37 (01): : A163 - A163
  • [29] THE CURRENT STATUS OF PULSE OXIMETRY - CLINICAL-VALUE OF CONTINUOUS NONINVASIVE OXYGEN-SATURATION MONITORING
    TAYLOR, MB
    WHITWAM, JG
    [J]. ANAESTHESIA, 1986, 41 (09) : 943 - 949
  • [30] INTRAPARTUM FETAL PULSE OXIMETRY - FETAL OXYGEN-SATURATION TRENDS DURING LABOR AND RELATION TO DELIVERY OUTCOME
    DILDY, GA
    VANDENBERG, PP
    KATZ, M
    CLARK, SL
    JONGSMA, HW
    NIJHUIS, JG
    LOUCKS, CA
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1994, 171 (03) : 679 - 684