Assessment of fetal scalp oxygen saturation determination in the sheep by transmission pulse oximetry

被引:10
|
作者
Nijland, MJM
Shankar, U
Iyer, V
Ross, MG
机构
[1] Cornell Univ, Coll Vet Med, Dept Biomed Sci, Lab Pregnancy & Newborn Res, Ithaca, NY 14853 USA
[2] Respiron Inc, Marietta, GA USA
[3] Univ Calif Los Angeles, Sch Med, Dept Obstet & Gynecol, Perinatal Res Labs, Los Angeles, CA 90024 USA
关键词
fetal scalp transmission pulse oximetry; oxygen saturation; sheep;
D O I
10.1067/mob.2000.107736
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
OBJECTIVE: Electronic fetal heart rate monitoring has an unacceptable false-positive nonreassuring rate, which results in an excess of operative interventions. As a more objective measure of fetal oxygenation, fetal ;scalp pulse oximetry has been used to assess fetal blood oxygen saturation (SO2). The current devices use reflectance oximetry, which has inherent limitations. These include varying depths of signal penetration, variation with position, and potential for optical interference. In this study we evaluated a newly developed transmission pulse oximetry device consisting of transmitter and receiver diodes mounted within the coil of a standard scalp electrode (Spiral O(2)CTG; Respironics Inc, Marietta, Ga). STUDY DESIGN: Six pregnant ewes at 127 to 135 days' gestation (term, 145 days' gestation) were anesthetized, intubated, and prepared with a femoral artery catheter. Fetuses were prepared with brachial artery and jugular vein catheters. Maternal inspired oxygen fraction was titrated from 21% to 3%. Oximetry O(2)CTG devices were positioned on the fetal scalp, and recordings were compared with directly determined fetal arterial pH, Pop, and So, values. RESULTS: Maternal Sao(2) and Pao(2) ranged from 102% to 16% and 110 to 18 mm Hg, respectively. Fetal Sao(2) and Pao(2) ranged from 76% to 12% and 28 to 8 mm Hg, respectively. There was excellent correlation between direct fetal Sao(2) and scalp So(2) (r(2) = 0.90; scalp So(2) = 0.79 Sao(2) + 6.89). With an Sao(2) of <30% as the cutoff point for assessment of fetal compromise, scalp So, measurements had a 94% +/- 10% specificity and a 94% +/- 10% positive predictive value. CONCLUSION: (1) Preliminary studies of the Spiral O(2)CTG sensor demonstrated high correlation of scalp So(2) with fetal Sao(2). (2) Although potential inaccuracies remain, transmission oximetry may offer potential advantages in consistency, ease of application, and technology with respect to the current reflection oximeter devices.
引用
收藏
页码:1549 / 1553
页数:5
相关论文
共 50 条
  • [21] The safety of fetal pulse oximetry in parturients requiring fetal scalp blood sampling
    Luttkus, AK
    Friedmann, W
    Thomas, S
    Dimer, JAS
    Dudenhausen, JW
    OBSTETRICS AND GYNECOLOGY, 1997, 90 (04): : 533 - 537
  • [22] INTRAPARTUM FETAL PULSE OXIMETRY - FETAL OXYGEN-SATURATION TRENDS DURING LABOR AND RELATION TO DELIVERY OUTCOME
    DILDY, GA
    VANDENBERG, PP
    KATZ, M
    CLARK, SL
    JONGSMA, HW
    NIJHUIS, JG
    LOUCKS, CA
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1994, 171 (03) : 679 - 684
  • [23] Effect of variable decelerations of FHR on fetal oxygen saturation measured by pulse oximetry during labor
    de Morais, EN
    Spara, P
    El Beitune, P
    Madi, JM
    PERINATOLOGY 2001, VOLS 1 AND 2, 2001, : 287 - 290
  • [24] Fetal pulse oximetry improves intrapartum fetal assessment
    Carrillo, J
    Insunza, A
    Latorre, R
    Mercado, M
    Cardenas, F
    Novoa, JM
    Paiva, E
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2003, 189 (06) : S184 - S184
  • [25] THE EFFECT ON FETAL ARTERIOLAR OXYGEN-SATURATION RESULTING FROM GIVING OXYGEN TO THE MOTHER MEASURED BY PULSE OXIMETRY
    MCNAMARA, H
    JOHNSON, N
    LILFORD, R
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1993, 100 (05): : 446 - 449
  • [26] NASAL PULSE OXIMETRY OVERESTIMATES OXYGEN-SATURATION
    ROSENBERG, J
    PEDERSEN, MH
    ANAESTHESIA, 1990, 45 (12) : 1070 - 1071
  • [27] Racial Disparity in Oxygen Saturation Measurements by Pulse Oximetry
    Jamali, Haya
    Castillo, Lauren T.
    Morgan, Chelsea Cosby
    Coult, Jason
    Muhammad, Janice L.
    Osobamiro, Oyinkansola O.
    Parsons, Elizabeth C.
    Adamson, Rosemary
    ANNALS OF THE AMERICAN THORACIC SOCIETY, 2022, 19 (12) : 1951 - 1964
  • [28] MONITORING OF ARTERIAL OXYGEN-SATURATION BY PULSE OXIMETRY
    STRIEBEL, HW
    STEINHOFF, U
    KRETZ, FJ
    ANASTHESIOLOGIE & INTENSIVMEDIZIN, 1988, 29 (01): : 8 - 16
  • [29] Arterial Oxygen Saturation, Pulse Oximetry, and Cerebral and Tissue Oximetry in Hypobaric Hypoxia
    Ottestad, William
    Kasin, Jan Ivar
    Hoiseth, Lars Oivind
    AEROSPACE MEDICINE AND HUMAN PERFORMANCE, 2018, 89 (12) : 1045 - 1049
  • [30] The effect of supplemental maternal oxygen on intrapartum fetal oxygen saturation using the nellcor N-400 fetal pulse oximetry system
    Connelly, M
    Morishita, M
    Miller, H
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2004, 191 (06) : S152 - S152