Assessment of fetal scalp oxygen saturation determination in the sheep by transmission pulse oximetry

被引:10
|
作者
Nijland, MJM
Shankar, U
Iyer, V
Ross, MG
机构
[1] Cornell Univ, Coll Vet Med, Dept Biomed Sci, Lab Pregnancy & Newborn Res, Ithaca, NY 14853 USA
[2] Respiron Inc, Marietta, GA USA
[3] Univ Calif Los Angeles, Sch Med, Dept Obstet & Gynecol, Perinatal Res Labs, Los Angeles, CA 90024 USA
关键词
fetal scalp transmission pulse oximetry; oxygen saturation; sheep;
D O I
10.1067/mob.2000.107736
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
OBJECTIVE: Electronic fetal heart rate monitoring has an unacceptable false-positive nonreassuring rate, which results in an excess of operative interventions. As a more objective measure of fetal oxygenation, fetal ;scalp pulse oximetry has been used to assess fetal blood oxygen saturation (SO2). The current devices use reflectance oximetry, which has inherent limitations. These include varying depths of signal penetration, variation with position, and potential for optical interference. In this study we evaluated a newly developed transmission pulse oximetry device consisting of transmitter and receiver diodes mounted within the coil of a standard scalp electrode (Spiral O(2)CTG; Respironics Inc, Marietta, Ga). STUDY DESIGN: Six pregnant ewes at 127 to 135 days' gestation (term, 145 days' gestation) were anesthetized, intubated, and prepared with a femoral artery catheter. Fetuses were prepared with brachial artery and jugular vein catheters. Maternal inspired oxygen fraction was titrated from 21% to 3%. Oximetry O(2)CTG devices were positioned on the fetal scalp, and recordings were compared with directly determined fetal arterial pH, Pop, and So, values. RESULTS: Maternal Sao(2) and Pao(2) ranged from 102% to 16% and 110 to 18 mm Hg, respectively. Fetal Sao(2) and Pao(2) ranged from 76% to 12% and 28 to 8 mm Hg, respectively. There was excellent correlation between direct fetal Sao(2) and scalp So(2) (r(2) = 0.90; scalp So(2) = 0.79 Sao(2) + 6.89). With an Sao(2) of <30% as the cutoff point for assessment of fetal compromise, scalp So, measurements had a 94% +/- 10% specificity and a 94% +/- 10% positive predictive value. CONCLUSION: (1) Preliminary studies of the Spiral O(2)CTG sensor demonstrated high correlation of scalp So(2) with fetal Sao(2). (2) Although potential inaccuracies remain, transmission oximetry may offer potential advantages in consistency, ease of application, and technology with respect to the current reflection oximeter devices.
引用
收藏
页码:1549 / 1553
页数:5
相关论文
共 50 条
  • [41] PULSE OXIMETRY IN METHEMOGLOBINEMIA - FAILURE TO DETECT LOW OXYGEN-SATURATION
    RIEDER, HU
    FREI, FJ
    ZBINDEN, AM
    THOMSON, DA
    ANAESTHESIA, 1989, 44 (04) : 326 - 327
  • [42] Effects of Motion Artifact on the Blood Oxygen Saturation Estimate in Pulse Oximetry
    Clarke, Geoffrey W. J.
    Chan, Adrian D. C.
    Adler, Andy
    2014 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2014, : 275 - 278
  • [43] Oxygen saturation nomogram by pulse oximetry in the first 24 h of life
    Habboub, Lina Hussain M.
    Salameh, Khalil Mohd Khalil
    Abedin, Sarfrazul
    Vellamgot, Anvar Paraparambil
    Valappil, Rajesh Pattu
    Salim, Sajid Thyvilayil
    Elkabir, Naser Abulgasim Mohamed
    JOURNAL OF CLINICAL NEONATOLOGY, 2021, 10 (04) : 216 - 219
  • [44] The effect of shellac nail polish on measurement of oxygen saturation by pulse oximetry
    Loy, M.
    Riddell, L.
    ANAESTHESIA, 2014, 69 : 42 - 42
  • [46] Oxygen Saturation Behavior by Pulse Oximetry in Female Athletes: Breaking Myths
    Martin-Escudero, Pilar
    Cabanas, Ana Maria
    Fuentes-Ferrer, Manuel
    Galindo-Canales, Mercedes
    BIOSENSORS-BASEL, 2021, 11 (10):
  • [47] Effects of henna dye on oxygen saturation reading using pulse oximetry
    Samman, YS
    Rahimi, JS
    Wali, SO
    Krayem, AB
    Abdelaziz, MM
    SAUDI MEDICAL JOURNAL, 2006, 27 (02) : 268 - 269
  • [48] Pulse Oximetry and Arterial Oxygen Saturation during Cardiopulmonary Exercise Testing
    Ascha, Mona
    Bhattacharyya, Anirban
    Ramos, Jose A.
    Tonelli, Adriano R.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2018, 50 (10): : 1992 - 1997
  • [49] THE EFFECT OF CARBOXYHEMOGLOBIN ON PULSE-OXIMETRY OXYGEN-SATURATION MEASUREMENTS
    PANACEK, EA
    JOURILLES, NJ
    SHERMAN, BW
    RUTHERFORD, WF
    CLINICAL RESEARCH, 1991, 39 (02): : A421 - A421
  • [50] Discrepancies between Arterial Oxygen Saturation and Functional Oxygen Saturation Measured with Pulse Oximetry in Very Preterm Infants
    Rosychuk, Rhonda J.
    Hudson-Mason, Ann
    Eklund, Dianne
    Lacaze-Masmonteil, Thierry
    NEONATOLOGY, 2012, 101 (01) : 14 - 19