Assessment of antral grinding of a model solid meal with echo-planar imaging

被引:160
|
作者
Marciani, L
Gowland, PA
Fillery-Travis, A
Manoj, P
Wright, J
Smith, A
Young, P
Moore, R
Spiller, RC [1 ]
机构
[1] Univ Nottingham Hosp, Queens Med Ctr, Div Gastroenterol, Nottingham NG7 2UH, England
[2] Sch Phys & Astron, Magnet Resonance Ctr, Nottingham NG7 2RD, England
[3] Inst Food Res, Norwich NR4 7UA, Norfolk, England
关键词
stomach; viscosity; gastric motility; gastric emptying; magnetic resonance imaging;
D O I
10.1152/ajpgi.2001.280.5.G844
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Mathematical modeling of how physical factors alter gastric emptying is limited by lack of precise measures of the forces exerted on gastric contents. We have produced agar gel beads (diameter 1.27 cm) with a range of fracture strengths (0.15-0.90 N) and assessed their breakdown by measuring their half-residence time (RT1/2) using magnetic resonance imaging. Beads were ingested either with a high (HV)- or low (LV)- viscosity liquid nutrient meal. With the LV meal, RT1/2 was similar for bead strengths ranging from 0.15 to 0.65 N but increased from 22 +/- 2 min (bead strength <0.65 N) to 65 +/- 12 min for bead strengths >0.65 N. With the HV meal, emptying of the harder beads was accelerated. The sense of fullness after ingesting the LV meal correlated linearly (correlation coefficient = 0.99) with gastric volume and was independently increased by the harder beads, which were associated with an increased antral diameter. We conclude that the maximum force exerted by the gastric antrum is close to 0.65 N and that gastric sieving is impaired by HV meals.
引用
收藏
页码:G844 / G849
页数:6
相关论文
共 50 条
  • [21] LIMITS TO NEURAL STIMULATION IN ECHO-PLANAR IMAGING
    MANSFIELD, P
    HARVEY, PR
    MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (06) : 746 - 758
  • [22] Reducing flow artifacts in echo-planar imaging
    Pat, GTL
    Meyer, CH
    Pauly, JM
    Nishimura, DG
    MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (03) : 436 - 447
  • [23] Multiple-shot echo-planar imaging
    Hennel, F
    CONCEPTS IN MAGNETIC RESONANCE, 1997, 9 (01): : 43 - 58
  • [24] Volumetric multishot echo-planar spectroscopic imaging
    Tyszka, JM
    Mamelak, AN
    MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (02) : 219 - 227
  • [25] REFINEMENTS IN CLINICAL ECHO-PLANAR MR IMAGING
    REIMER, P
    SAINI, S
    HAHN, PF
    GOLDBERG, M
    MUELLER, PR
    WEISSKOFF, R
    RADIOLOGY, 1992, 185 : 234 - 234
  • [26] DUAL-ECHO INTERLEAVED ECHO-PLANAR IMAGING OF THE BRAIN
    SLAVIN, GS
    BUTTS, K
    RYDBERG, JN
    JACK, CR
    RIEDERER, SJ
    MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (02) : 264 - 270
  • [27] Silent echo-planar imaging for auditory FMRI
    S. Schmitter
    E. Diesch
    M. Amann
    A. Kroll
    M. Moayer
    L. R. Schad
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2008, 21 : 317 - 325
  • [28] Correction of Shearing Distortions in Echo-Planar Imaging
    Liu, Guoxiang
    Oshio, Koichi
    Ogawa, Seiji
    Murata, Tsutomu
    IEEE TRANSACTIONS ON MAGNETICS, 2010, 46 (07) : 2628 - 2634
  • [29] Motion robust GRAPPA for echo-planar imaging
    Baron, Corey A.
    Beaulieu, Christian
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (03) : 1166 - 1174
  • [30] Silent echo-planar imaging for auditory FMRI
    Schmitter, S.
    Diesch, E.
    Amann, M.
    Kroll, A.
    Moayer, M.
    Schad, L. R.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2008, 21 (05) : 317 - 325