Assessment of antral grinding of a model solid meal with echo-planar imaging

被引:160
|
作者
Marciani, L
Gowland, PA
Fillery-Travis, A
Manoj, P
Wright, J
Smith, A
Young, P
Moore, R
Spiller, RC [1 ]
机构
[1] Univ Nottingham Hosp, Queens Med Ctr, Div Gastroenterol, Nottingham NG7 2UH, England
[2] Sch Phys & Astron, Magnet Resonance Ctr, Nottingham NG7 2RD, England
[3] Inst Food Res, Norwich NR4 7UA, Norfolk, England
关键词
stomach; viscosity; gastric motility; gastric emptying; magnetic resonance imaging;
D O I
10.1152/ajpgi.2001.280.5.G844
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Mathematical modeling of how physical factors alter gastric emptying is limited by lack of precise measures of the forces exerted on gastric contents. We have produced agar gel beads (diameter 1.27 cm) with a range of fracture strengths (0.15-0.90 N) and assessed their breakdown by measuring their half-residence time (RT1/2) using magnetic resonance imaging. Beads were ingested either with a high (HV)- or low (LV)- viscosity liquid nutrient meal. With the LV meal, RT1/2 was similar for bead strengths ranging from 0.15 to 0.65 N but increased from 22 +/- 2 min (bead strength <0.65 N) to 65 +/- 12 min for bead strengths >0.65 N. With the HV meal, emptying of the harder beads was accelerated. The sense of fullness after ingesting the LV meal correlated linearly (correlation coefficient = 0.99) with gastric volume and was independently increased by the harder beads, which were associated with an increased antral diameter. We conclude that the maximum force exerted by the gastric antrum is close to 0.65 N and that gastric sieving is impaired by HV meals.
引用
收藏
页码:G844 / G849
页数:6
相关论文
共 50 条
  • [41] The development of echo-planar imaging (EPI): 1977–1982
    R. Ordidge
    Magnetic Resonance Materials in Physics, Biology and Medicine, 1999, 9 (3) : 117 - 121
  • [42] REAL-TIME ECHO-PLANAR IMAGING BY NMR
    MANSFIELD, P
    BRITISH MEDICAL BULLETIN, 1984, 40 (02) : 187 - &
  • [43] In vivo echo-planar imaging of rat spinal cord
    Fenyes, DA
    Narayana, PA
    MAGNETIC RESONANCE IMAGING, 1998, 16 (10) : 1249 - 1255
  • [44] Echo-planar FLAIR imaging in evaluation of intracranial lesions
    Simonson, TM
    Magnotta, VA
    Ehrhardt, JC
    Crosby, DL
    Fisher, DJ
    Yuh, WTC
    RADIOGRAPHICS, 1996, 16 (03) : 575 - 584
  • [45] INTERLEAVED ECHO-PLANAR IMAGING ON A STANDARD MRI SYSTEM
    BUTTS, K
    RIEDERER, SJ
    EHMAN, RL
    THOMPSON, RM
    JACK, CR
    MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (01) : 67 - 72
  • [46] Lactate discrimination incorporated into echo-planar spectroscopic imaging
    Bito, Y
    Ebisu, T
    Hirata, S
    Takegami, T
    Yamamoto, Y
    Tanaka, C
    Naruse, S
    MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (04) : 568 - 574
  • [47] REAL-TIME ECHO-PLANAR IMAGING IN PEDIATRICS
    MANSFIELD, P
    RZEDZIAN, R
    DOYLE, M
    CHAPMAN, B
    GUILFOYLE, D
    COUPLAND, R
    CHRISPIN, A
    SMALL, P
    MAGNETIC RESONANCE IN MEDICINE, 1984, 1 (02) : 197 - 199
  • [48] FUNCTIONAL ECHO-PLANAR MR IMAGING AT 1.0 T
    STEHLING, MK
    SCHMITT, F
    LADEBECK, R
    RADIOLOGY, 1992, 185 : 199 - 199
  • [49] Ghost artifact suppression for interleaved echo-planar imaging
    Buonocore, MH
    Zhu, D
    Bronstein, JM
    RADIOLOGY, 1998, 209P : 356 - 357
  • [50] Readout-segmented echo-planar imaging in diffusion-weighted imaging of the kidney: comparison with single-shot echo-planar imaging in image quality
    Chen-Jiang Wu
    Qing Wang
    Jing Zhang
    Xiao-Ning Wang
    Xi-Sheng Liu
    Yu-Dong Zhang
    Hai-Bin Shi
    Abdominal Radiology, 2016, 41 : 100 - 108