Assessment of antral grinding of a model solid meal with echo-planar imaging

被引:160
|
作者
Marciani, L
Gowland, PA
Fillery-Travis, A
Manoj, P
Wright, J
Smith, A
Young, P
Moore, R
Spiller, RC [1 ]
机构
[1] Univ Nottingham Hosp, Queens Med Ctr, Div Gastroenterol, Nottingham NG7 2UH, England
[2] Sch Phys & Astron, Magnet Resonance Ctr, Nottingham NG7 2RD, England
[3] Inst Food Res, Norwich NR4 7UA, Norfolk, England
关键词
stomach; viscosity; gastric motility; gastric emptying; magnetic resonance imaging;
D O I
10.1152/ajpgi.2001.280.5.G844
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Mathematical modeling of how physical factors alter gastric emptying is limited by lack of precise measures of the forces exerted on gastric contents. We have produced agar gel beads (diameter 1.27 cm) with a range of fracture strengths (0.15-0.90 N) and assessed their breakdown by measuring their half-residence time (RT1/2) using magnetic resonance imaging. Beads were ingested either with a high (HV)- or low (LV)- viscosity liquid nutrient meal. With the LV meal, RT1/2 was similar for bead strengths ranging from 0.15 to 0.65 N but increased from 22 +/- 2 min (bead strength <0.65 N) to 65 +/- 12 min for bead strengths >0.65 N. With the HV meal, emptying of the harder beads was accelerated. The sense of fullness after ingesting the LV meal correlated linearly (correlation coefficient = 0.99) with gastric volume and was independently increased by the harder beads, which were associated with an increased antral diameter. We conclude that the maximum force exerted by the gastric antrum is close to 0.65 N and that gastric sieving is impaired by HV meals.
引用
收藏
页码:G844 / G849
页数:6
相关论文
共 50 条
  • [31] ECHO-PLANAR IMAGING OF INTRAVOXEL INCOHERENT MOTION
    TURNER, R
    LEBIHAN, D
    MAIER, J
    VAVREK, R
    HEDGES, LK
    PEKAR, J
    RADIOLOGY, 1990, 177 (02) : 407 - 414
  • [32] PHASE ERRORS IN MULTISHOT ECHO-PLANAR IMAGING
    FEINBERG, DA
    OSHIO, K
    MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (04) : 535 - 539
  • [33] ECHO-PLANAR IMAGING OF THE HUMAN FETUS INUTERO
    STEHLING, MK
    MANSFIELD, P
    ORDIDGE, RJ
    COXON, R
    CHAPMAN, B
    BLAMIRE, A
    GIBBS, P
    JOHNSON, IR
    SYMONDS, EM
    WORTHINGTON, BS
    COUPLAND, RE
    MAGNETIC RESONANCE IN MEDICINE, 1990, 13 (02) : 314 - 318
  • [34] ANALYSIS OF FLOW EFFECTS IN ECHO-PLANAR IMAGING
    BUTTS, K
    RIEDERER, SJ
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (03): : 285 - 293
  • [35] Single-shot echo-planar imaging with Nyquist ghost compensation: Interleaved dual echo with acceleration (IDEA) echo-planar imaging (EPI)
    Poser, Benedikt A.
    Barth, Markus
    Goa, Pal-Erik
    Deng, Weiran
    Stenger, V. Andrew
    MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (01) : 37 - 47
  • [36] Rapid MR angiography with echo-planar imaging
    Atkinson, DJ
    Chen, D
    Bradley, WG
    RADIOLOGY, 1996, 201 : 1532 - 1532
  • [37] Gastric response to increased meal viscosity assessed by echo-planar magnetic resonance imaging in humans
    Marciani, L
    Gowland, PA
    Spiller, RC
    Manoj, P
    Moore, RJ
    Young, P
    Al-Sahab, S
    Bush, D
    Wright, J
    Fillery-Travis, AJ
    JOURNAL OF NUTRITION, 2000, 130 (01): : 122 - 127
  • [38] FUNCTIONAL MAGNETIC-RESONANCE-IMAGING WITH ECHO-PLANAR IMAGING
    KWONG, KK
    MAGNETIC RESONANCE QUARTERLY, 1995, 11 (01) : 1 - 20
  • [39] Three dimensional echo-planar imaging at 7 Tesla
    Poser, B. A.
    Koopmans, P. J.
    Witzel, T.
    Wald, L. L.
    Barth, M.
    NEUROIMAGE, 2010, 51 (01) : 261 - 266
  • [40] The b matrix in diffusion tensor echo-planar imaging
    Mattiello, J
    Basser, PJ
    LeBihan, D
    MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (02) : 292 - 300