Volumetric multishot echo-planar spectroscopic imaging

被引:10
|
作者
Tyszka, JM
Mamelak, AN
机构
[1] City Hope Natl Med Ctr, Beckman Res Inst, Div Mol Med, Duarte, CA 91010 USA
[2] City Hope Natl Med Ctr, Div Surg, Duarte, CA 91010 USA
关键词
magnetic resonance imaging; echo-planar imaging; spectroscopic imaging; phase correction; human brain metabolism;
D O I
10.1002/mrm.1182
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rapid volumetric magnetic resonance spectroscopic imaging (MRSI) is potentially of great relevance to the diagnosis and treatment of focal cerebral diseases such as cancer and epilepsy. A strategy for volumetric multishot echo-planar spectroscopic imaging (MEPSI) is described which allows whole-brain metabolite mapping in approximately 20 min. A multishot trajectory is used in both the spatial and temporal domains which reduces the accumulated phase during each echo train and tolerates conventional Fourier reconstruction without regridding. Also described is a generalized correction for phase discontinuities arising from the multishot acquisition of the time domain, which is independent of the spatial k-space trajectory and is therefore also applicable to multishot spiral MRSI. Whole-brain, lipid-suppressed MEPSI data were acquired from five normal subjects. The mean signal-to-noise ratios (SNRs) (+/- SE) for the n-acetylaspartate (NAA), choline (Cho), and creatine (Cr) maps across all subjects were 21.3 +/- 1.8, 11.7 +/- 0.6, and 9.2 +/- 0.6, respectively, with a computed voxel size of 2.33 ml. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:219 / 227
页数:9
相关论文
共 50 条
  • [1] PHASE ERRORS IN MULTISHOT ECHO-PLANAR IMAGING
    FEINBERG, DA
    OSHIO, K
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (04) : 535 - 539
  • [2] Pseudo multishot echo-planar imaging for geometric distortion improvement
    Chen, Hao
    Dai, Ke
    Bao, Jianfeng
    Zhong, Sijie
    Hu, Chenxi
    Liu, Yiling
    Zhang, Zhiyong
    [J]. NMR IN BIOMEDICINE, 2023, 36 (05)
  • [3] Accuracy of multishot echo-planar imaging for ventricular function indexes
    Lewis, KH
    Oshinski, JN
    Dixon, WT
    Pettigrew, RI
    [J]. RADIOLOGY, 1996, 201 : 1492 - 1492
  • [4] SELECTIVE MULTISHOT ECHO-PLANAR IR IMAGING IN PEDIATRIC NEURORADIOLOGY
    POSKITT, KJ
    SARGENT, MA
    [J]. RADIOLOGY, 1995, 197 : 269 - 269
  • [5] Normal myocardial perfusion assessed with multishot echo-planar imaging
    Schwitter, J
    Debatin, JF
    vonSchulthess, GK
    McKinnon, GC
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (01) : 140 - 147
  • [6] ECHO-PLANAR DIFFUSION SPECTROSCOPIC IMAGING
    BITO, Y
    HIRATA, S
    NABESHIMA, T
    YAMAMOTO, E
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (01) : 69 - 73
  • [7] Image-Based Reduction of Artifacts in Multishot Echo-Planar Imaging
    MR Centre, FORENAP, 68250 Rouffach, France
    [J]. J. Magn. Reson., 2 (206-213):
  • [8] Image-based reduction of artifacts in multishot echo-planar imaging
    Hennel, F
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1998, 134 (02) : 206 - 213
  • [9] Detection of Middle Ear Cholesteatoma by Diffusion-Weighted MR Imaging: Multishot Echo-Planar Imaging Compared with Single-Shot Echo-Planar Imaging
    Yamashita, K.
    Yoshiura, T.
    Hiwatashi, A.
    Kamano, H.
    Dashjamts, T.
    Shibata, S.
    Tamae, A.
    Honda, H.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (10) : 1915 - 1918
  • [10] Multivendor implementation and comparison of volumetric whole-brain echo-planar MR spectroscopic imaging
    Sabati, Mohammad
    Sheriff, Sulaiman
    Gu, Meng
    Wei, Juan
    Zhu, Henry
    Barker, Peter B.
    Spielman, Daniel M.
    Alger, Jeffry R.
    Maudsley, Andrew A.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (05) : 1209 - 1220