Correction of Shearing Distortions in Echo-Planar Imaging

被引:2
|
作者
Liu, Guoxiang [1 ,2 ]
Oshio, Koichi [3 ]
Ogawa, Seiji [4 ]
Murata, Tsutomu [1 ]
机构
[1] Natl Inst Informat & Commun Technol, Biol ICT Grp, Kobe, Hyogo, Japan
[2] JST, CREST, Tokyo, Japan
[3] Keio Univ, Sch Med, Dept Diagnost Radiol, Tokyo, Japan
[4] Tohoku Fukushi Univ, Sendai, Miyagi, Japan
关键词
Distortion; echo-planar imaging (EPI); eddy currents; magnetic resonance imaging; EPI; REDUCTION; FMRI;
D O I
10.1109/TMAG.2010.2041785
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this study, the existence of linear geometric distortions due to readout (RO) train-induced background gradients was investigated under homogeneity; this paper was aimed at deriving and implementing a simple method for correcting such linear geometric distortions without carrying out the reference measurements of field errors within the echo-planar imaging (EPI) acquisition window. The background gradient in the EPI acquisition window in the RO direction was estimated from the autocorrelation phase, which was calculated from the complex-valued RO1-D inverse-Fourier-transformed k-space (x-ky space). All the correction procedures were performed in the complex domain in the hybrid x-ky space after acquiring the data. No prior adjustments or additional measurements are required, and this correction algorithm can be applied to most EPI techniques. The echo-planar images of several phantoms and a human brain were acquired with one 1.5-T and two 3-T MRI systems to validate the effectiveness of the correction method. The severe global spatial shearing distortion caused by the linear background RO gradient in the images was corrected, and improvements were observed in all cases. The results indicate that distortions caused by the background RO gradient under homogeneity can be corrected by online processing, even in high-resolution echo-planar images such as 128 X 128 pixel imaging.
引用
收藏
页码:2628 / 2634
页数:7
相关论文
共 50 条
  • [1] ECHO-PLANAR IMAGING
    DELAPAZ, RL
    RADIOGRAPHICS, 1994, 14 (05) : 1045 - 1058
  • [2] Echo-Planar Imaging
    University of Nottingham, United Kingdom
    eMagRes, 2007,
  • [3] VISUALIZATION OF LOCAL SHEARING MOTION IN TURBULENT FLUIDS USING ECHO-PLANAR IMAGING
    KOSE, K
    JOURNAL OF MAGNETIC RESONANCE, 1992, 96 (03): : 596 - 603
  • [4] ECHO-PLANAR IMAGING OF PERFLUOROCARBONS
    BARKER, BR
    MASON, RP
    PESHOCK, RM
    MAGNETIC RESONANCE IMAGING, 1993, 11 (08) : 1165 - 1173
  • [5] ADVANCES IN ECHO-PLANAR IMAGING
    MANSFIELD, P
    DOYLE, M
    CHAPMAN, B
    GUILFOYLE, D
    CAWLEY, M
    COUPLAND, RE
    CHRISPIN, A
    SMALL, P
    BRITISH JOURNAL OF RADIOLOGY, 1985, 58 (690): : 583 - 584
  • [6] Echo-planar imaging of the uterus
    Kiryu, S
    Okada, Y
    Matsuoka, Y
    Abe, O
    Ohtomo, K
    Sasaki, Y
    RADIOLOGY, 1996, 201 : 595 - 595
  • [7] Radial echo-planar imaging
    Silva, AC
    Barbier, EL
    Lowe, IJ
    Koretsky, AP
    JOURNAL OF MAGNETIC RESONANCE, 1998, 135 (01) : 242 - 247
  • [8] ECHO-PLANAR IMAGING OF THE ABDOMEN
    MULLER, MF
    EDELMAN, RR
    TOPICS IN MAGNETIC RESONANCE IMAGING, 1995, 7 (02) : 112 - 119
  • [9] Echo-planar MR imaging
    Kanal, E
    RADIOLOGY, 1996, 198 (02) : 585 - 586
  • [10] Reduction of geometric and intensity distortions in echo-planar imaging using a multireference scan
    Wan, X
    Gullberg, GT
    Parker, DL
    Zeng, GL
    MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (06) : 932 - 942