Correction of Shearing Distortions in Echo-Planar Imaging

被引:2
|
作者
Liu, Guoxiang [1 ,2 ]
Oshio, Koichi [3 ]
Ogawa, Seiji [4 ]
Murata, Tsutomu [1 ]
机构
[1] Natl Inst Informat & Commun Technol, Biol ICT Grp, Kobe, Hyogo, Japan
[2] JST, CREST, Tokyo, Japan
[3] Keio Univ, Sch Med, Dept Diagnost Radiol, Tokyo, Japan
[4] Tohoku Fukushi Univ, Sendai, Miyagi, Japan
关键词
Distortion; echo-planar imaging (EPI); eddy currents; magnetic resonance imaging; EPI; REDUCTION; FMRI;
D O I
10.1109/TMAG.2010.2041785
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this study, the existence of linear geometric distortions due to readout (RO) train-induced background gradients was investigated under homogeneity; this paper was aimed at deriving and implementing a simple method for correcting such linear geometric distortions without carrying out the reference measurements of field errors within the echo-planar imaging (EPI) acquisition window. The background gradient in the EPI acquisition window in the RO direction was estimated from the autocorrelation phase, which was calculated from the complex-valued RO1-D inverse-Fourier-transformed k-space (x-ky space). All the correction procedures were performed in the complex domain in the hybrid x-ky space after acquiring the data. No prior adjustments or additional measurements are required, and this correction algorithm can be applied to most EPI techniques. The echo-planar images of several phantoms and a human brain were acquired with one 1.5-T and two 3-T MRI systems to validate the effectiveness of the correction method. The severe global spatial shearing distortion caused by the linear background RO gradient in the images was corrected, and improvements were observed in all cases. The results indicate that distortions caused by the background RO gradient under homogeneity can be corrected by online processing, even in high-resolution echo-planar images such as 128 X 128 pixel imaging.
引用
收藏
页码:2628 / 2634
页数:7
相关论文
共 50 条
  • [21] PSF mapping-based correction of eddy-current-induced distortions in diffusion-weighted echo-planar imaging
    In, Myung-Ho
    Posnansky, Oleg
    Speck, Oliver
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (05) : 2055 - 2063
  • [22] Distortion correction in echo-planar imaging and quantitative T2* mapping
    Dierkes, T
    Neeb, H
    Shah, NJ
    QUANTITATION IN BIOMEDICAL IMAGING WITH PET AND MRI, 2004, (1265): : 181 - 185
  • [23] Correction of B1 inhomogeneities using echo-planar imaging of water
    Thulborn, KR
    Boada, FE
    Shen, GX
    Christensen, JD
    Reese, TG
    MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (03) : 369 - 375
  • [24] LIMITS TO NEURAL STIMULATION IN ECHO-PLANAR IMAGING
    MANSFIELD, P
    HARVEY, PR
    MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (06) : 746 - 758
  • [25] Reducing flow artifacts in echo-planar imaging
    Pat, GTL
    Meyer, CH
    Pauly, JM
    Nishimura, DG
    MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (03) : 436 - 447
  • [26] Echo-planar rotating-frame imaging
    Casanova, F
    Robert, H
    Perlo, J
    Pusiol, D
    JOURNAL OF MAGNETIC RESONANCE, 2003, 162 (02) : 396 - 401
  • [27] Multiple-shot echo-planar imaging
    Hennel, F
    CONCEPTS IN MAGNETIC RESONANCE, 1997, 9 (01): : 43 - 58
  • [28] Volumetric multishot echo-planar spectroscopic imaging
    Tyszka, JM
    Mamelak, AN
    MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (02) : 219 - 227
  • [29] REFINEMENTS IN CLINICAL ECHO-PLANAR MR IMAGING
    REIMER, P
    SAINI, S
    HAHN, PF
    GOLDBERG, M
    MUELLER, PR
    WEISSKOFF, R
    RADIOLOGY, 1992, 185 : 234 - 234
  • [30] DUAL-ECHO INTERLEAVED ECHO-PLANAR IMAGING OF THE BRAIN
    SLAVIN, GS
    BUTTS, K
    RYDBERG, JN
    JACK, CR
    RIEDERER, SJ
    MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (02) : 264 - 270