Correction of Shearing Distortions in Echo-Planar Imaging

被引:2
|
作者
Liu, Guoxiang [1 ,2 ]
Oshio, Koichi [3 ]
Ogawa, Seiji [4 ]
Murata, Tsutomu [1 ]
机构
[1] Natl Inst Informat & Commun Technol, Biol ICT Grp, Kobe, Hyogo, Japan
[2] JST, CREST, Tokyo, Japan
[3] Keio Univ, Sch Med, Dept Diagnost Radiol, Tokyo, Japan
[4] Tohoku Fukushi Univ, Sendai, Miyagi, Japan
关键词
Distortion; echo-planar imaging (EPI); eddy currents; magnetic resonance imaging; EPI; REDUCTION; FMRI;
D O I
10.1109/TMAG.2010.2041785
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this study, the existence of linear geometric distortions due to readout (RO) train-induced background gradients was investigated under homogeneity; this paper was aimed at deriving and implementing a simple method for correcting such linear geometric distortions without carrying out the reference measurements of field errors within the echo-planar imaging (EPI) acquisition window. The background gradient in the EPI acquisition window in the RO direction was estimated from the autocorrelation phase, which was calculated from the complex-valued RO1-D inverse-Fourier-transformed k-space (x-ky space). All the correction procedures were performed in the complex domain in the hybrid x-ky space after acquiring the data. No prior adjustments or additional measurements are required, and this correction algorithm can be applied to most EPI techniques. The echo-planar images of several phantoms and a human brain were acquired with one 1.5-T and two 3-T MRI systems to validate the effectiveness of the correction method. The severe global spatial shearing distortion caused by the linear background RO gradient in the images was corrected, and improvements were observed in all cases. The results indicate that distortions caused by the background RO gradient under homogeneity can be corrected by online processing, even in high-resolution echo-planar images such as 128 X 128 pixel imaging.
引用
收藏
页码:2628 / 2634
页数:7
相关论文
共 50 条
  • [31] Silent echo-planar imaging for auditory FMRI
    S. Schmitter
    E. Diesch
    M. Amann
    A. Kroll
    M. Moayer
    L. R. Schad
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2008, 21 : 317 - 325
  • [32] Motion robust GRAPPA for echo-planar imaging
    Baron, Corey A.
    Beaulieu, Christian
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (03) : 1166 - 1174
  • [33] ECHO-PLANAR IMAGING OF THE HUMAN FETUS INUTERO
    STEHLING, MK
    MANSFIELD, P
    ORDIDGE, RJ
    COXON, R
    CHAPMAN, B
    BLAMIRE, A
    GIBBS, P
    JOHNSON, IR
    SYMONDS, EM
    WORTHINGTON, BS
    COUPLAND, RE
    MAGNETIC RESONANCE IN MEDICINE, 1990, 13 (02) : 314 - 318
  • [34] ECHO-PLANAR IMAGING OF INTRAVOXEL INCOHERENT MOTION
    TURNER, R
    LEBIHAN, D
    MAIER, J
    VAVREK, R
    HEDGES, LK
    PEKAR, J
    RADIOLOGY, 1990, 177 (02) : 407 - 414
  • [35] PHASE ERRORS IN MULTISHOT ECHO-PLANAR IMAGING
    FEINBERG, DA
    OSHIO, K
    MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (04) : 535 - 539
  • [36] Silent echo-planar imaging for auditory FMRI
    Schmitter, S.
    Diesch, E.
    Amann, M.
    Kroll, A.
    Moayer, M.
    Schad, L. R.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2008, 21 (05) : 317 - 325
  • [37] ANALYSIS OF FLOW EFFECTS IN ECHO-PLANAR IMAGING
    BUTTS, K
    RIEDERER, SJ
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (03): : 285 - 293
  • [38] Real-Time Geometric Distortion Correction for Interventional Imaging with Echo-Planar Imaging (EPI)
    Dragonu, Iulius
    de Senneville, Baudouin Denis
    Quesson, Bruno
    Moonen, Chrit
    Ries, Mario
    MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (04) : 994 - 1000
  • [39] Single-shot echo-planar imaging with Nyquist ghost compensation: Interleaved dual echo with acceleration (IDEA) echo-planar imaging (EPI)
    Poser, Benedikt A.
    Barth, Markus
    Goa, Pal-Erik
    Deng, Weiran
    Stenger, V. Andrew
    MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (01) : 37 - 47
  • [40] Rapid MR angiography with echo-planar imaging
    Atkinson, DJ
    Chen, D
    Bradley, WG
    RADIOLOGY, 1996, 201 : 1532 - 1532