摘要
Methodology for PET system modeling using image-space techniques in the expectation maximization (EM) algorithm is presented. The approach, applicable to both list-mode data an projection data, is of particular significance to EM algorithm implementations which otherwise only use basic system models (such as those which calculate the system matrix elements on the fly). A basic version of the proposed technique can be implemented using image-space convolution, in order to include resolution effects into the system matrix, so that the EM algorithm gradually recovers the modeled resolution with each update. The improved system modeling (achieved by inclusion of two convolutions per iteration) results in both enhanced resolution and lower noise, and there is often no need for regularization-other than to limit the number of iterations. Tests have been performed with simulated list-mode data and also with measured projection data from a GE Advance PET scanner, for both [F-18]-FDG and [I-124]-NaI. The method demonstrates improved image quality in all cases when compared to the conventional FBP and EM methods presently used for clinical data (which do not include resolution modeling). The benefits of this approach for I-124 (which has a low positron yield and a large positron range, usually resulting in noisier and poorer resolution images) are particularly noticeable.
引用
收藏
页码:1392 / 1397
页数:6
相关论文
共 50 条
  • [41] Reconstruction of Dual Isotope PET Using Expectation Maximization (EM) Algorithm
    Sitek, Arkadiusz
    Andreyev, Andriy
    Celler, Anna
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4323 - 4326
  • [42] A SYSTEM FOR THE 3D RECONSTRUCTION OF RETRACTED-SEPTA PET DATA USING THE EM ALGORITHM
    JOHNSON, CA
    YAN, YC
    CARSON, RE
    MARTINO, RL
    DAUBEWITHERSPOON, ME
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) : 1223 - 1227
  • [43] A Comparison of Resolution Recovery Performed in Projection-Space and Image-Space for a High Resolution Small Animal PET Scanner
    Baghaei, Hossain
    Li, Hongdi
    Zhang, Yuxuan
    Ramirez, Rocio A.
    Wong, Wai-Hoi
    [J]. 2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [44] DOI-PET image reconstruction with accurate system modeling that reduces redundancy of the imaging system
    Yamaya, T
    Hagiwara, N
    Obi, T
    Yamaguchi, M
    Kita, K
    Ohyama, N
    Kitamura, K
    Hasegawa, T
    Haneishi, H
    Murayama, H
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (05) : 1404 - 1409
  • [45] PET image reconstruction: A robust state space approach
    Liu, HF
    Tian, Y
    Shi, PC
    [J]. INFORMATION PROCESSING IN MEDICAL IMAGING, PROCEEDINGS, 2005, 3565 : 197 - 209
  • [46] ON THE ITERATIVE IMAGE SPACE RECONSTRUCTION ALGORITHM FOR ECT
    TITTERINGTON, DM
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1987, 6 (01) : 52 - 56
  • [47] ON THE RATE OF CONVERGENCE OF THE IMAGE SPACE RECONSTRUCTION ALGORITHM
    Han, Jian
    Han, Lixing
    Neumann, Michael
    Prasad, Upendra
    [J]. OPERATORS AND MATRICES, 2009, 3 (01): : 41 - 58
  • [48] Positron range modeling for statistical PET image reconstruction
    Bai, T
    Ruangma, A
    Laforest, R
    Tai, YC
    Leahy, RM
    [J]. 2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2501 - 2505
  • [49] Spatially Compact MR-Guided Kernel EM for PET Image Reconstruction
    Bland, James
    Belzunce, Martin A.
    Ellis, Sam
    McGinnity, Colm J.
    Hammers, Alexander
    Reader, Andrew J.
    [J]. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2018, 2 (05) : 470 - 482
  • [50] An iterative algorithm for conductivity image reconstruction from crosswell EM measurements
    Zhang, YC
    Liu, C
    Shen, LC
    [J]. GEOPHYSICS, 1996, 61 (04) : 987 - 997