A Comparison of Resolution Recovery Performed in Projection-Space and Image-Space for a High Resolution Small Animal PET Scanner

被引:0
|
作者
Baghaei, Hossain [1 ]
Li, Hongdi [1 ]
Zhang, Yuxuan [1 ]
Ramirez, Rocio A. [1 ]
Wong, Wai-Hoi [1 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Canc Syst Imaging, Houston, TX 77030 USA
关键词
RECONSTRUCTION; GATE;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Advances in PET scanner design and image reconstruction methods have lead to the development of high resolution emission tomographic scanners. Traditional PET reconstruction methods that do not take into account the mispositioning of the lines of response (parallax error) result in blurring images and increased distortion with increased distance from the center of the field-of-view. The image quality can be improved by performing resolution recovery (RR) using a point spread function (PSF) which describes the response of the system to point source. For a high-resolution small animal PET scanner, we studied the resolution recovery modeling in projection-space using a Gaussian-PSF or Monte-Carlo (MC) simulated PSF. We also studied the RR in image-space using the Gaussian-PSF. For this work, we used data that were acquired by scanning a Micro Deluxe phantom and a healthy mouse. The resolution recovery approach which used Gaussian-PSF, with a fixed FWHM, improved the spatial resolution and enhanced image contrast compared to the standard image reconstruction. The resolution recovery method which used the MC simulated spatially variant-PSF further improved the resolution compared to the simple Gaussian-based PSF.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] EM algorithm resolution modeling by image-space convolution for PET reconstruction
    Reader, AJ
    Julyan, PJ
    Williams, H
    Hastings, DL
    Zweit, J
    [J]. 2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1221 - 1225
  • [2] Impact of image-space resolution modeling for studies with the high-resolution research tomograph
    Sureau, Florent C.
    Reader, Andrew J.
    Comtat, Claude
    Leroy, Claire
    Ribeiro, Maria-Joao
    Buvat, Irene
    Trebossen, Regine
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2008, 49 (06) : 1000 - 1008
  • [3] High Resolution PET Image Reconstruction for the Siemens MR/PET-hybrid BrainPET Scanner in LOR space
    Scheins, J. J.
    Tellmann, L.
    Weirich, Ch.
    Kops, E. Rota
    Michel, Ch.
    Byars, L. G.
    Schmand, M.
    Herzog, H.
    [J]. 2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2981 - +
  • [4] STUDY ON LISTMODE OSEM RECONSTRUCTION INCLUDING IMAGE-SPACE RESOLUTION RECOVERY TECHNIQUES FOR COMPTON CAMERA
    Kim, S. M.
    Lee, J. S.
    Park, M. J.
    Seo, H.
    Kim, C. H.
    Lee, C. S.
    Lee, D. S.
    Lee, S-J
    [J]. 2010 7TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2010, : 796 - 799
  • [5] A feasibility study of PETiPIX: an ultra high resolution small animal PET scanner
    Li, K.
    Safavi-Naeini, M.
    Franklin, D. R.
    Petasecca, M.
    Guatelli, S.
    Rosenfeld, A. B.
    Hutton, B. F.
    Lerch, M. L. F.
    [J]. JOURNAL OF INSTRUMENTATION, 2013, 8
  • [6] A small animal PET scanner with millimeter spatial resolution.
    Del Guerra, A
    Di Domenico, G
    Scandola, M
    Zavattini, G
    Giganti, M
    Uccelli, L
    Piffanelli, A
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 133P - 133P
  • [7] Design and Development of PETiPIX: An Ultra High Spatial Resolution Small Animal PET Scanner
    Li, K.
    Safavi-Naeini, M.
    Franklin, D. R.
    Petasecca, M.
    Guatelli, S.
    Rosenfeld, A. B.
    Hutton, B. F.
    Lerch, M. L. F.
    [J]. 2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [8] Multi-resolution image reconstruction for a high-resolution small animal PET device
    Clinthorne, NH
    Park, S
    Rogers, WL
    Chiao, PC
    [J]. 2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 1997 - 2001
  • [9] Spatial Resolution and Sensitivity of the Inveon Small-Animal PET Scanner
    Visser, Eric P.
    Disselhorst, Jonathan A.
    Brom, Maarten
    Laverman, Peter
    Gotthardt, Martin
    Oyen, Wim J. G.
    Boerman, Otto C.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (01) : 139 - 147
  • [10] The ClearPET™:: A high resolution high sensitivity dual-layer phoswich small animal PET scanner
    Heinrichs, U
    Bruyndonckx, P
    Choi, Y
    Dietzel, G
    Korjik, M
    Lecoq, P
    Morel, C
    Pedrini, C
    Petrosyan, AG
    Pietrzyk, U
    Sappey-Marinier, D
    Streun, M
    Tavernier, S
    Ziemons, K
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S400 - S400