Impact of image-space resolution modeling for studies with the high-resolution research tomograph

被引:194
|
作者
Sureau, Florent C. [1 ,2 ]
Reader, Andrew J. [3 ]
Comtat, Claude [1 ]
Leroy, Claire [4 ]
Ribeiro, Maria-Joao [1 ]
Buvat, Irene [5 ]
Trebossen, Regine [1 ]
机构
[1] CEA, Serv Hosp Frederic Joliot, I2BM, DSV, F-91406 Orsay, France
[2] Siemens Med Solut SAS, St Denis, France
[3] Univ Manchester, Sch Chem Engn & Analyt Sci, Manchester, Lancs, England
[4] CEA, Serv Hosp Frederic Joliot, INSERM, UMR 797, F-91406 Orsay, France
[5] CHU Pitie Salpetriere, UPMC, INSERM, UMR 678, Paris, France
关键词
PET imaging; partial-volume effects; resolution modeling;
D O I
10.2967/jnumed.107.045351
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Brain PET in small structures is challenged by low resolution inducing bias in the activity measurements. Improved spatial resolution may be obtained by using dedicated tomographs and more comprehensive modeling of the acquisition system during reconstruction. In this study, we assess the impact of resolution modeling (RM) during reconstruction on image quality and on the estimates of biologic parameters in a clinical study performed on a high-resolution research tomograph. Methods: An accelerated list-mode ordinary Poisson ordered-subset expectation maximization (OP-OSEM) algorithm, including sinogram-based corrections and an experimental stationary model of resolution, has been designed. Experimental phantom studies are used to assess contrast and noise characteristics of the reconstructed images. The binding potential of a selective tracer of the dopamine transporter is also assessed in anatomic volumes of interest in a 5-patient study. Results: In the phantom experiment, a slower convergence and a higher contrast recovery are observed for RM-OP-OSEM than for OP-OSEM for the same level of statistical noise. RM-OP-OSEM yields contrast recovery levels that could not be reached without RM as well as better visual recovery of the smallest spheres and better delineation of the structures in the reconstructed images. Statistical noise has lower variance at the voxel level with RM than without at matched resolution. In a uniform activity region, RM induces higher positive and lower negative correlations with neighboring voxels, leading to lower spatial variance. Clinical images reconstructed with RM demonstrate better delineation of cortical and subcortical structures in both time-averaged and parametric images. The binding potential in the striatum is also increased, a result similar to the one observed in the phantom study. Conclusion: In high-resolution PET, RM during reconstruction improves quantitative accuracy by reducing the partial-volume effects.
引用
收藏
页码:1000 / 1008
页数:9
相关论文
共 50 条
  • [1] IMPACT OF NEW SCATTER CORRECTION STRATEGIES ON HIGH-RESOLUTION RESEARCH TOMOGRAPH PET STUDIES
    Mansor, M.
    Boellaard, R.
    Huisman, M. C.
    van Berckel, B. N. M.
    Lammertsma, A. A.
    van Velden, F. H. P.
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2016, 36 : 636 - 637
  • [2] Impact of New Scatter Correction Strategies on High-Resolution Research Tomograph Brain PET Studies
    Syahir Mansor
    Ronald Boellaard
    Marc C. Huisman
    Bart N. M. van Berckel
    Robert C. Schuit
    Albert D. Windhorst
    Adriaan A. Lammertsma
    Floris H. P. van Velden
    [J]. Molecular Imaging and Biology, 2016, 18 : 627 - 635
  • [3] Impact of New Scatter Correction Strategies on High-Resolution Research Tomograph Brain PET Studies
    Mansor, Syahir
    Boellaard, Ronald
    Huisman, Marc C.
    van Berckel, Bart N. M.
    Schuit, Robert C.
    Windhorst, Albert D.
    Lammertsma, Adriaan A.
    van Velden, Floris H. P.
    [J]. MOLECULAR IMAGING AND BIOLOGY, 2016, 18 (04) : 627 - 635
  • [4] EM algorithm resolution modeling by image-space convolution for PET reconstruction
    Reader, AJ
    Julyan, PJ
    Williams, H
    Hastings, DL
    Zweit, J
    [J]. 2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1221 - 1225
  • [5] Image-derived input function for brain imaging using the high-resolution research tomograph
    Zanotti-Fregonara, Paolo
    Liow, Jeih-San
    Fujita, Masahiro
    Zoghbi, Sami S.
    Comtat, Claude
    Elise, Luong
    Boellaard, Ronald
    Pike, Victor W.
    Innis, Robert B.
    [J]. NEUROIMAGE, 2010, 52 : S222 - S222
  • [6] Impact of attenuation correction strategies on the quantification of High Resolution Research Tomograph PET studies
    van Velden, Floris H. P.
    Kloet, Reina W.
    van Berckel, Bart N. M.
    Molthoff, Carla F. M.
    de Jong, Hugo W. A. M.
    Lammertsma, Adriaan A.
    Boellaard, Ronald
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (01): : 99 - 118
  • [7] Quantification of dynamic brain studies with the high resolution research tomograph
    de Jong, HWAM
    Boellaard, R
    Michel, C
    Lammertsma, AA
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3730 - 3732
  • [8] A Comparison of Resolution Recovery Performed in Projection-Space and Image-Space for a High Resolution Small Animal PET Scanner
    Baghaei, Hossain
    Li, Hongdi
    Zhang, Yuxuan
    Ramirez, Rocio A.
    Wong, Wai-Hoi
    [J]. 2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [9] Image derived input functions for dynamic High Resolution Research Tomograph PET brain studies
    Mourik, Jurgen E. M.
    van Velden, Floris H. P.
    Lubberink, Mark
    Kloet, Reina W.
    van Berckel, Bart N. M.
    Lammertsma, Adriaan A.
    Boellaard, Ronald
    [J]. NEUROIMAGE, 2008, 43 (04) : 676 - 686
  • [10] Research on Large Scene Production Method of High-resolution Space Satellite Image
    Wu, Ruihong
    Zhang, Weilong
    Shi, Shuo
    Deng, Chuan
    Fang, Shiming
    Liu, Yalin
    [J]. Journal of Railway Engineering Society, 2023, 40 (08): : 23 - 28