EM algorithm system modeling by image-space techniques for PET reconstruction

被引:168
|
作者
Reader, AJ [1 ]
Julyan, PJ
Williams, H
Hastings, DL
Zweit, J
机构
[1] UMIST, DIAS, Manchester M60 1QD, Lancs, England
[2] Paterson Inst Canc Res, Manchester M20 4BX, Lancs, England
[3] Christie Hosp NHS Trust, Manchester M20 4BX, Lancs, England
关键词
iterative image reconstruction; positron emission tomography (PET);
D O I
10.1109/TNS.2003.817327
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Methodology for PET system modeling using image-space techniques in the expectation maximization (EM) algorithm is presented. The approach, applicable to both list-mode data an projection data, is of particular significance to EM algorithm implementations which otherwise only use basic system models (such as those which calculate the system matrix elements on the fly). A basic version of the proposed technique can be implemented using image-space convolution, in order to include resolution effects into the system matrix, so that the EM algorithm gradually recovers the modeled resolution with each update. The improved system modeling (achieved by inclusion of two convolutions per iteration) results in both enhanced resolution and lower noise, and there is often no need for regularization-other than to limit the number of iterations. Tests have been performed with simulated list-mode data and also with measured projection data from a GE Advance PET scanner, for both [F-18]-FDG and [I-124]-NaI. The method demonstrates improved image quality in all cases when compared to the conventional FBP and EM methods presently used for clinical data (which do not include resolution modeling). The benefits of this approach for I-124 (which has a low positron yield and a large positron range, usually resulting in noisier and poorer resolution images) are particularly noticeable.
引用
收藏
页码:1392 / 1397
页数:6
相关论文
共 50 条
  • [32] Impact of image-space resolution modeling for studies with the high-resolution research tomograph
    Sureau, Florent C.
    Reader, Andrew J.
    Comtat, Claude
    Leroy, Claire
    Ribeiro, Maria-Joao
    Buvat, Irene
    Trebossen, Regine
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2008, 49 (06) : 1000 - 1008
  • [33] Improved quantitation for PET/CT image reconstruction with system modeling and anatomical priors
    Alessio, AM
    Kinahan, PE
    Lewellen, TK
    [J]. MEDICAL IMAGING 2005: IMAGE PROCESSING, PT 1-3, 2005, 5747 : 695 - 703
  • [34] Improved quantitation for PET/CT image reconstruction with system modeling and anatomical priors
    Alessio, Adam M.
    Kinahan, Paul E.
    [J]. MEDICAL PHYSICS, 2006, 33 (11) : 4095 - 4103
  • [35] Performance Evaluation of an Image-Space Observer-Based Visual Servoing System
    Okiyama, Ko
    Murakami, Toshiyuki
    [J]. ELECTRICAL ENGINEERING IN JAPAN, 2016, 196 (02) : 34 - 43
  • [36] Research on the influence of swing mirror of infrared imaging system with image-space scanning
    Liu, Zhiying
    Gao, Liuxu
    Wang, Jiake
    Tian, Yu
    [J]. INFRARED PHYSICS & TECHNOLOGY, 2018, 92 : 459 - 465
  • [37] Three penalized EM-type algorithms for PET image reconstruction
    Teng, Yueyang
    Zhang, Tie
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2012, 42 (06) : 714 - 723
  • [38] A stopping criterion for the iterative EM-MLE image reconstruction for PET
    Kontaxakis, GN
    Tzanakos, GS
    [J]. MEDICAL IMAGING 1996: IMAGE PROCESSING, 1996, 2710 : 133 - 144
  • [39] Kernelised EM Image Reconstruction for Dual-Dataset PET Studies
    Ellis, Sam
    Reader, Andrew J.
    [J]. 2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [40] An Analytical Approach to the Image Reconstruction Problem Using EM Algorithm
    Dobosz, Piotr
    [J]. ARTIFICIAL INTELLIGENCE AND SOFT COMPUTING, PT I, 2012, 7267 : 495 - 500