Effect of clothing on sphygmomanometric and oscillometric blood pressure measurement in hypertensive subjects

被引:8
|
作者
Eder, M. J. C. [1 ]
Holzgreve, H. [2 ]
Liebl, M. E. [3 ]
Bogner, J. R. [1 ]
机构
[1] Univ Munich, Klinikum Innenstadt, Med Poliklin, D-80336 Munich, Germany
[2] Kardiol Praxis, Munich, Germany
[3] Abt Orthopad, Med Klin, Berlin, Germany
关键词
hypertension; blood pressure measurement; oscillometry; sphygmomanometry; clothes;
D O I
10.1055/s-2008-1077254
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and objective: The few studies published on this subject have shown that blood pressure measurements give similar results whether the patients' arm is covered by clothing or not. But it has not been clarified whether this is also true in the case of hypertensive persons, Yet, in practice the correct measurement is of critical importance in the diagnosis of hypertension. Methods: 203 hypertensive patients were examined with the auscultatory sphygmomanometry and the automatic oscillometry by measuring the pressure three times with each method. These tests were carried out in a randomized sequence on a covered arm (the patient's own clothing of maximally 2 mm thickness), the bare arm and the arm covered with a standardized cotton sleeve (2 mm). The auscultatory sphygmomanometry was done blinded (non-sleeved, sleeved, standardized). Results: Calculation of confidence intervals for the mean differences of the three settings (bare, clothing and standard sleeve) and equivalence testing demonstrated that a garment or cloth on the arm under the manometer cuffs did not significantly effect the blood pressure within the predefined interval of equivalence of 4 mm Hg. Thus, measuring blood pressure with the cuff over the person's sleeve does not significantly effect the result. Conclusion: This study shows that measuring blood pressure in hypertensive persons with or without a cloth sleeve (maximally 2 mm thick) does not result in any statistically significant difference. This simplifies the blood pressure measurement that have to be taken frequently on hypertensive persons.
引用
收藏
页码:1288 / 1292
页数:5
相关论文
共 50 条
  • [31] Patient-Specific Oscillometric Blood Pressure Measurement
    Liu, Jiankun
    Cheng, Hao-Min
    Chen, Chen-Huan
    Sung, Shih-Hsien
    Moslehpour, Mohsen
    Hahn, Jin-Oh
    Mukkamala, Ramakrishna
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2016, 63 (06) : 1220 - 1228
  • [32] Effect of respiration on Korotkoff sounds and oscillometric cuff pressure pulses during blood pressure measurement
    Zheng, Dingchang
    Di Marco, Luigi Yuri
    Murray, Alan
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2014, 52 (05) : 467 - 473
  • [33] Effect of respiration on Korotkoff sounds and oscillometric cuff pressure pulses during blood pressure measurement
    Dingchang Zheng
    Luigi Yuri Di Marco
    Alan Murray
    Medical & Biological Engineering & Computing, 2014, 52 : 467 - 473
  • [34] The effect of intravenous metoclopramide on blood pressure in normotensive and hypertensive subjects
    Blanco, M
    Jelambi, I
    Perez, G
    Gomez, J
    Franco, T
    Hurtado, N
    Velasco, M
    INTERNATIONAL JOURNAL OF CLINICAL PHARMACOLOGY AND THERAPEUTICS, 1996, 34 (09) : 390 - 392
  • [35] Pulse arrhythmia diagnosis by oscillometric blood pressure measurement
    Forstner, KW
    AMERICAN JOURNAL OF HYPERTENSION, 2003, 16 (05) : 48A - 48A
  • [36] Accuracy of oscillometric blood pressure measurement in atrial fibrillation
    Feenstra, Rudolf K.
    Allaart, Cor P.
    Berkelmans, Gijs F. N.
    Westerhof, Berend E.
    Smulders, Yvo M.
    BLOOD PRESSURE MONITORING, 2018, 23 (02) : 59 - 63
  • [37] Algorithm of oscillometric blood pressure measurement applied on microcontroller
    Angyal, David
    Vagner, Aniko
    Juhasz, Istvan
    2018 IEEE INTERNATIONAL CONFERENCE ON FUTURE IOT TECHNOLOGIES (FUTURE IOT), 2018,
  • [38] Development of a new oscillometric blood pressure measurement system
    Moraes, JCTB
    Cerulli, M
    Ng, PS
    COMPUTERS IN CARDIOLOGY 1999, VOL 26, 1999, 26 : 467 - 470
  • [39] Oscillometric blood pressure measurement: Description of the method used
    Wonka, F
    ZEITSCHRIFT FUR KARDIOLOGIE, 1996, 85 : 1 - 7
  • [40] Auscultatory versus oscillometric measurement of blood pressure in octogenarians
    Rosholm, Jens-Ulrik
    Arnspang, Sidsel
    Matzen, Lars
    Jacobsen, Ib A.
    BLOOD PRESSURE, 2012, 21 (05) : 269 - 272